96 research outputs found

    PET Reconstruction With an Anatomical MRI Prior Using Parallel Level Sets.

    Get PDF
    The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) offers unique possibilities. In this paper we aim to exploit the high spatial resolution of MRI to enhance the reconstruction of simultaneously acquired PET data. We propose a new prior to incorporate structural side information into a maximum a posteriori reconstruction. The new prior combines the strengths of previously proposed priors for the same problem: it is very efficient in guiding the reconstruction at edges available from the side information and it reduces locally to edge-preserving total variation in the degenerate case when no structural information is available. In addition, this prior is segmentation-free, convex and no a priori assumptions are made on the correlation of edge directions of the PET and MRI images. We present results for a simulated brain phantom and for real data acquired by the Siemens Biograph mMR for a hardware phantom and a clinical scan. The results from simulations show that the new prior has a better trade-off between enhancing common anatomical boundaries and preserving unique features than several other priors. Moreover, it has a better mean absolute bias-to-mean standard deviation trade-off and yields reconstructions with superior relative l2-error and structural similarity index. These findings are underpinned by the real data results from a hardware phantom and a clinical patient confirming that the new prior is capable of promoting well-defined anatomical boundaries.This research was funded by the EPSRC (EP/K005278/1) and EP/H046410/1 and supported by the National Institute for Health Research University College London Hospitals Biomedical Research Centre. M.J.E was supported by an IMPACT studentship funded jointly by Siemens and the UCL Faculty of Engineering Sciences. K.T. and D.A. are partially supported by the EPSRC grant EP/M022587/1.This is the author accepted manuscript. The final version is available from IEEE via http://dx.doi.org/10.1109/TMI.2016.254960

    Multi-Level Canonical Correlation Analysis for Standard-Dose PET Image Estimation

    Get PDF
    Positron emission tomography (PET) images are widely used in many clinical applications such as tumor detection and brain disorder diagnosis. To obtain PET images of diagnostic quality, a sufficient amount of radioactive tracer has to be injected into a living body, which will inevitably increase the risk of radiation exposure. On the other hand, if the tracer dose is considerably reduced, the quality of the resulting images would be significantly degraded. It is of great interest to estimate a standard-dose PET (S-PET) image from a low-dose one in order to reduce the risk of radiation exposure and preserve image quality. This may be achieved through mapping both standard-dose and low-dose PET data into a common space and then performing patch based sparse representation. However, a one-size-fits-all common space built from all training patches is unlikely to be optimal for each target S-PET patch, which limits the estimation accuracy. In this paper, we propose a data-driven multi-level Canonical Correlation Analysis (mCCA) scheme to solve this problem. Specifically, a subset of training data that is most useful in estimating a target S-PET patch is identified in each level, and then used in the next level to update common space and improve estimation. Additionally, we also use multi-modal magnetic resonance images to help improve the estimation with complementary information. Validations on phantom and real human brain datasets show that our method effectively estimates S-PET images and well preserves critical clinical quantification measures, such as standard uptake value

    (An overview of) Synergistic reconstruction for multimodality/multichannel imaging methods

    Get PDF
    Imaging is omnipresent in modern society with imaging devices based on a zoo of physical principles, probing a specimen across different wavelengths, energies and time. Recent years have seen a change in the imaging landscape with more and more imaging devices combining that which previously was used separately. Motivated by these hardware developments, an ever increasing set of mathematical ideas is appearing regarding how data from different imaging modalities or channels can be synergistically combined in the image reconstruction process, exploiting structural and/or functional correlations between the multiple images. Here we review these developments, give pointers to important challenges and provide an outlook as to how the field may develop in the forthcoming years. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 1'

    Patch-based anisotropic diffusion scheme for fluorescence diffuse optical tomography-part 1: technical principles

    Get PDF
    Fluorescence diffuse optical tomography (fDOT) provides 3D images of fluorescence distributions in biological tissue, which represent molecular and cellular processes. The image reconstruction problem is highly ill-posed and requires regularisation techniques to stabilise and find meaningful solutions. Quadratic regularisation tends to either oversmooth or generate very noisy reconstructions, depending on the regularisation strength. Edge preserving methods, such as anisotropic diffusion regularisation (AD), can preserve important features in the fluorescence image and smooth out noise. However, AD has limited ability to distinguish an edge from noise. In this two-part paper, we propose a patch-based anisotropic diffusion regularisation (PAD), where regularisation strength is determined by a weighted average according to the similarity between patches around voxels within a search window, instead of a simple local neighbourhood strategy. However, this method has higher computational complexity and, hence, we wavelet compress the patches (PAD-WT) to speed it up, while simultaneously taking advantage of the denoising properties of wavelet thresholding. The proposed method combines the nonlocal means (NLM), AD and wavelet shrinkage methods, which are image processing methods. Therefore, in this first paper, we used a denoising test problem to analyse the performance of the new method. Our results show that the proposed PAD-WT method provides better results than the AD or NLM methods alone. The efficacy of the method for fDOT image reconstruction problem is evaluated in part 2

    Level Set Method for Positron Emission Tomography

    Get PDF
    In positron emission tomography (PET), a radioactive compound is injected into the body to promote a tissue-dependent emission rate. Expectation maximization (EM) reconstruction algorithms are iterative techniques which estimate the concentration coefficients that provide the best fitted solution, for example, a maximum likelihood estimate. In this paper, we combine the EM algorithm with a level set approach. The level set method is used to capture the coarse scale information and the discontinuities of the concentration coefficients. An intrinsic advantage of the level set formulation is that anatomical information can be efficiently incorporated and used in an easy and natural way. We utilize a multiple level set formulation to represent the geometry of the objects in the scene. The proposed algorithm can be applied to any PET configuration, without major modifications

    Multitracer Guided PET Image Reconstruction

    Get PDF

    Quantitative Image Reconstruction Methods for Low Signal-To-Noise Ratio Emission Tomography

    Full text link
    Novel internal radionuclide therapies such as radioembolization (RE) with Y-90 loaded microspheres and targeted therapies labeled with Lu-177 offer a unique promise for personalized treatment of cancer because imaging-based pre-treatment dosimetry assessment can be used to determine administered activities, which deliver tumoricidal absorbed doses to lesions while sparing critical organs. At present, however, such therapies are administered with fixed or empiric activities with little or no dosimetry planning. The main reason for lack of dosimetry guided personalized treatment in radionuclide therapies is the challenges and impracticality of quantitative emission tomography imaging and the lack of well established dose-effect relationships, potentially due to inaccuracies in quantitative imaging. While radionuclides for therapy have been chosen for their attractive characteristics for cancer treatment, their suitability for emission tomography imaging is less than ideal. For example, imaging of the almost pure beta emitter, Y-90, involves SPECT via bremsstrahlung photons that have a low and tissue dependent yield or PET via a very low abundance positron emission (32 out of 1 million decays) that leads to a very low true coincidence-rate in the presence of high singles events from bremsstrahlung photons. Lu-177 emits gamma-rays suitable for SPECT, but they are low in intensity (113 keV: 6%, 208 keV: 10%), and only the higher energy emission is generally used because of the large downscatter component associated with the lower energy gamma-ray. The main aim of the research in this thesis is to improve accuracy of quantitative PET and SPECT imaging of therapy radionuclides for dosimetry applications. Although PET is generally considered as superior to SPECT for quantitative imaging, PET imaging of `non-pure' positron emitters can be complex. We focus on quantitative SPECT and PET imaging of two widely used therapy radionuclides, Lu-177 and Y-90, that have challenges associated with low count-rates. The long term goal of our work is to apply the methods we develop to patient imaging for dosimetry based planning to optimize the treatment either before therapy or after each cycle of therapy. For Y-90 PET/CT, we developed an image reconstruction formulation that relaxes the conventional image-domain nonnegativity constraint by instead imposing a positivity constraint on the predicted measurement mean that demonstrated improved quantification in simulated patient studies. For Y-90 SPECT/CT, we propose a new SPECT/CT reconstruction formulation including tissue dependent probabilities for bremsstrahlung generation in the system matrix. In addition to above mentioned quantitative image reconstruction methods specifically developed for each modality in Y-90 imaging, we propose a general image reconstruction method using trained regularizer for low-count PET and SPECT that we test on Y-90 and Lu-177 imaging. Our approach starts with the raw projection data and utilizes trained networks in the iterative image formation process. Specifically, we take a mathematics-based approach where we include convolutional neural networks within the iterative reconstruction process arising from an optimization problem. We further extend the trained regularization method by using anatomical side information. The trained regularizer incorporates the anatomical information using the segmentation mask generated by a trained segmentation network where its input is the co-registered CT image. Overall, the emission tomography methods we have proposed in this work are expected to enhance low-count PET and SPECT imaging of therapy radionuclides in patient studies, which will have value in establishing dose – response relationships and developing imaging based dosimetry guided treatment planning strategies in the future.PHDElectrical and Computer EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttps://deepblue.lib.umich.edu/bitstream/2027.42/155171/1/hongki_1.pd
    corecore