1,734 research outputs found

    In-depth investigation into the transient humidity response at the body-seat interface on initial contact using a dual temperature and humidity sensor

    Get PDF
    Relative humidity (RH) at the body-seat interface is considered an important factor in both sitting comfort and generation of health concerns such as skin lesions. Technical difficulties appear to have limited research aimed at the detailed and simultaneous exploration of RH and temperature changes at the body-seat interface; using RH sensors without the capability to record temperature where RH is recorded. To explore the causes of a spike in RH consistently produced on first contact between body and seat surface, we report data from the first use of dual temperature and RH (HTU21D) sensors in this interface. Following evaluation of sensor performance, the effect of local thermal changes on RH was investigated. The expected strong negative correlation between temperature and RH (R 2 = =0.94) supported the importance of considering both parameters when studying impact of sitting on skin health. The influence of sensor movement speed (higher velocity approach: 0.32 cm/s ± 0.01 cm/s; lower velocity approach: 0.17 cm/s ± 0.01 cm/s) into a static RH region associated with a higher local temperature were compared with data gathered by altering the rate of a person sitting. In all cases, the faster sitting down (or equivalent) generated larger RH outcomes: e.g., in human sitting 53.7% ± 3.3% RH (left mid-thigh), 56.4% ± 5.1% RH (right mid-thigh) and 53.2% ± 2.7% RH (Coccyx). Differences in size of RH change were seen across the measurement locations used to study the body-seat interface. The initial sitting contact induces a transient RH response (duration ≤ 40 s) that does not accurately reflect the microenvironment at the body-seat interface. It is likely that any movement during sitting would result in similar artefact formation. As a result, caution should be taken when investigating RH performance at any enclosed interface when the surfaces may have different temperatures and movement may occur

    Oral application of L-menthol in the heat: From pleasure to performance

    Get PDF
    When menthol is applied to the oral cavity it presents with a familiar refreshing sensation and cooling mint flavour. This may be deemed hedonic in some individuals, but may cause irritation in others. This variation in response is likely dependent upon trigeminal sensitivity toward cold stimuli, suggesting a need for a menthol solution that can be easily personalised. Menthol’s characteristics can also be enhanced by matching colour to qualitative outcomes; a factor which can easily be manipulated by practitioners working in athletic or occupational settings to potentially enhance intervention efficacy. This presentation will outline the efficacy of oral menthol application for improving time trial performance to date, either via swilling or via co-ingestion with other cooling strategies, with an emphasis upon how menthol can be applied in ecologically valid scenarios. Situations in which performance is not expected to be enhanced will also be discussed. An updated model by which menthol may prove hedonic, satiate thirst and affect ventilation will also be presented, with the potential performance implications of these findings discussed and modelled. Qualitative reflections from athletes that have implemented menthol mouth swilling in competition, training and maximal exercise will also be included

    Retention and application of Skylab experiences to future programs

    Get PDF
    The problems encountered and special techniques and procedures developed on the Skylab program are described along with the experiences and practical benefits obtained for dissemination and use on future programs. Three major topics are discussed: electrical problems, mechanical problems, and special techniques. Special techniques and procedures are identified that were either developed or refined during the Skylab program. These techniques and procedures came from all manufacturing and test phases of the Skylab program and include both flight and GSE items from component level to sophisticated spaceflight systems

    NASA Tech Briefs Index, 1976

    Get PDF
    Abstracts of new technology derived from the research and development activities of the National Aeronautics and Space Administration are presented. Emphasis is placed on information considered likely to be transferrable across industrial, regional, or disciplinary lines. Subject matter covered includes: electronic components and circuits; electronic systems; physical sciences; materials; life sciences; mechanics; machinery; fabrication technology; and mathematics and information sciences

    Experimental Measurements of Far Field Cough Airflows Produced by Healthy and Influenza- Infected Human Subjects

    Get PDF
    The present work details an experimental study of the cough airflow fields produced by subjects infected with influenza and when they are convalescent, together with data from healthy cohorts. The PIV and HWA measurements were taken far downstream at 1 m from the source within a cough chamber, along with droplet sampling at two different locations and nasal swabs from the sick subjects. The measured data over different seasons were used to evaluate and compare the results from sick, convalescent and healthy subjects. Although a total of 8 sick participants from winter 2014 and 2017 yielded positive nasal swab analysis, the total number of subjects involved in this work were 49 in number. The results from HWA show modest differences between sick and convalescent states of a participant, but the normalized cough velocity time histories from both the techniques follow similar trends. It is anticipated that a larger samples size will provide a clear conclusive difference among coughs from the three categories

    Modelling heat transfer and respiration of occupants in indoor climate

    Get PDF
    Although the terms "Human Thermal Comfort" and "Indoor Air Quality (IAQ)" can be highly subjective, they still dictate the indoor climate design (HVAC design) of a building. In order to evaluate human thermal comfort and IAQ, one of three main tools are used, a) direct questioning the subjects about their thermal and air quality sensation (voting, sampling etc.), b) measuring the human thermal comfort by recording the physical parameters such as relative humidity, air and radiation temperature, air velocities and concentration gradients of pollutants or c) by using numerical simulations either including or excluding detailed thermo-physiological models. The application of the first two approaches can only take place in post commissioning and/or testing phases of the building. Use of numerical techniques can however be employed at any stage of the building design. With the rapid development in computational hard- and software technology, the costs involved in numerical studies has reduced compared to detailed tests. Employing numerical modelling to investigate human thermal comfort and IAQ however demand thorough verification and validation studies. Such studies are used to understand the limitations and application of numerical modelling of human thermal comfort and IAQ in indoor climates. This PhD research is an endeavour to verify, validate and apply, numerical simulation for modelling heat transfer and respiration of occupants in indoor climates. Along with the investigations concerning convective and radiation heat transfer between the occupants and their surroundings, the work focuses on detailed respiration modelling of sedentary human occupants. The objectives of the work have been to: verify the convective and radiation numerical models; validate them for buoyancy-driven flows due to human occupants in indoor climates; and apply these validated models for investigating human thermal comfort and IAQ in a real classroom for which field study data was available. On the basis of the detailed verification, validation and application studies, the findings are summarized as a set of guidelines for simulating human thermal comfort and IAQ in indoor climates. This PhD research involves the use of detailed human body geometries and postures. Modelling radiation and investigating the effect of geometrical posture has shown that the effective radiation area varies significantly with posture. The simulation results have shown that by using an effective radiation area factor of 0.725, estimated previously (Fanger, 1972) for a standing person, can lead to an underestimation of effective radiation area by 13% for the postures considered. Numerical modelling of convective heat transfer and respiration processes for sedentary manikins have shown that the SST turbulence model (Menter, 1994) with appropriate resolution of near wall region can simulate the local air velocity, temperature and heat transfer coefficients to a level of detail required for prediction of thermal comfort and IAQ. The present PhD work has shown that in a convection dominated environment, the detailed seated manikins give rise to an asymmetrical thermal plume as compared to the thermal plumes generated by simplified manikins or point sources. Validated simulation results obtained during the present PhD work have shown that simplified manikins can be used without significant limitations while investigating IAQ of complete indoor spaces. The use of simplified manikins however does not seem appropriate when simulating detailed respiration effects in the immediate vicinity of seated humans because of the underestimation in the amount of re-inhaled CO2 and pollutants from the surroundings. Furthermore, the results have shown that due to the simplification in geometrical form of the nostrils, the CO2 concentration is much higher near the face region (direct jet along the nostrils) as compared to a detailed geometry (sideways jet). Simulating the complete respiration cycle has shown that a pause between exhalation and inhalation has a significant effect on the amount of re-inhaled CO2. Previous results have shown the amount of re-inhaled CO2 to range between 10 - 19%. The present study has shown that by considering the pause, this amount of re-inhaled CO2 falls down to values lower than 1%. A comparison between the simplified and detailed geometry has shown that a simplified geometry can cause an underestimation in the amount of re-inhaled CO2 by more than 37% as compared to a detailed geometry. The major contribution to knowledge delivered by this PhD work is the provision of a validated seated computational thermal manikin. This PhD work follows a structured verification and validation approach for conducting CFD simulations to predict human thermal comfort and indoor air quality. The work demonstrates the application of the validated model to a classroom case with multiple occupancy and compares the measured results with the simulation results. The comparison of CFD results with measured data advocates the use of CFD and visualizes the importance of modelling thermal manikins in indoor HVAC design rather than designing the HVAC by considering empty spaces as the occupancy has a strong influence on the indoor air flow. This PhD work enables the indoor climate researchers and building designers to employ simplified thermal manikin to correctly predict the mean flow characteristics in indoor surroundings. The present work clearly demonstrates the limitation of the PIV measurement technique, the importance of using detailed CFD manikin geometry when investigating the phenomena of respiration in detail and the effect of thermal plume around the seated manikin. This computational thermal manikin used in this work is valid for a seated adult female geometry

    Study of space shuttle environmental control and life support problems

    Get PDF
    Four problem areas were treated: (1) cargo module environmental control and life support systems; (2) space shuttle/space station interfaces; (3) thermal control considerations for payloads; and (4) feasibility of improving system reusability
    • …
    corecore