237 research outputs found

    An Adaptive Fuzzy Switching Filter for Images Corrupted by Impulse Noise

    Get PDF
    In digital images, impulse noise (such as salt and pepper noise) detection and removal is an important process as the images are corrupted by those noise because of transmission and acquisition. The main aim of the noise removal is to suppress the noise when preserving the edge information. The median filter and its derivatives are usually used for this purpose. These filtering techniques usually applied to the overall image and modify the pixel value. The modification in pixel values will be performed in unaffected pixels also. Hence the sufficient removal of impulse using this technique will leads to the reduction in quality of images. In this paper, Adaptive Fuzzy Switching Filter is proposed which is based on fuzzy logic for removing the impulse noise from the affected image. The proposed technique involves three phases. The first phase will detect the impulse noise by considering grayscale distribution among neighboring pixels. In the second phase, grayscale values for the pixels are determined based on the values of neighboring pixels. The final phase implements the fuzzy switching for further improvement in the image preservation. The fuzzy membership function used in the proposed technique is half open fuzzy membership function. The experimental result shows that the proposed adaptive fuzzy switching filter has the better capability of removing the impulse noise from the corrupted image

    Image Restoration for Remote Sensing: Overview and Toolbox

    Full text link
    Remote sensing provides valuable information about objects or areas from a distance in either active (e.g., RADAR and LiDAR) or passive (e.g., multispectral and hyperspectral) modes. The quality of data acquired by remotely sensed imaging sensors (both active and passive) is often degraded by a variety of noise types and artifacts. Image restoration, which is a vibrant field of research in the remote sensing community, is the task of recovering the true unknown image from the degraded observed image. Each imaging sensor induces unique noise types and artifacts into the observed image. This fact has led to the expansion of restoration techniques in different paths according to each sensor type. This review paper brings together the advances of image restoration techniques with particular focuses on synthetic aperture radar and hyperspectral images as the most active sub-fields of image restoration in the remote sensing community. We, therefore, provide a comprehensive, discipline-specific starting point for researchers at different levels (i.e., students, researchers, and senior researchers) willing to investigate the vibrant topic of data restoration by supplying sufficient detail and references. Additionally, this review paper accompanies a toolbox to provide a platform to encourage interested students and researchers in the field to further explore the restoration techniques and fast-forward the community. The toolboxes are provided in https://github.com/ImageRestorationToolbox.Comment: This paper is under review in GRS

    Speech Modeling and Robust Estimation for Diagnosis of Parkinson’s Disease

    Get PDF

    Aeronautical Engineering: A continuing bibliography, supplement 124

    Get PDF
    This bibliography, lists 450 reports, articles, and other documents introduced into the NASA scientific and technical information system in June 1980

    Aeronautical engineering: A continuing bibliography with indexes (supplement 279)

    Get PDF
    This bibliography lists 759 reports, articles, and other documents introduced into the NASA scientific and technical information system in May 1992. Subject coverage includes: design, construction, and testing of aircraft and aircraft engines; aircraft components, equipment, and systems; ground support systems; and theoretical and applied aspects of aerodynamics and general fluid dynamics

    Traitement et exploration d'images TDM pour l'évaluation des bioprothèses valvulaires aortiques

    Get PDF
    Le but de cette étude est d évaluer la faisabilité de l analyse tomodensitométrique 3D des bioprothèses aortiques pour faciliter leur évaluation morphologique durant le suivi et d aider la sélection de cas et améliorer la planification d une procédure valvein-valve. Le challenge était représenté par le rehaussement des feuillets valvulaires, en raison d images très bruitées. Un angio-scanner synchronisé était réalisé chez des patients porteurs d une bioprotèses aortique dégénérée avant réintervention (images in-vivo). Différentes méthodes pour la réduction du bruit étaient proposées. La reconstruction tridimensionnelle des bioprothèses était réalisée en utilisant des méthodes de segmentation de régions par "sticks". Après réopération ces méthodes étaient appliquées aux images scanner des bioprothèses explantées (images ex-vivo) et utilisées comme référence. La réduction du bruit obtenue par le filtre stick modifié montrait meilleurs résultats en rapport signal/bruit en comparaison aux filtres de diffusion anisotropique. Toutes les méthodes de segmentation ont permis une reconstruction 3D des feuillets. L analyse qualitative a montré une bonne concordance entre les images obtenues in-vivo et les altérations des bioprothèses. Les résultats des différentes méthodes étaient comparés par critères volumétriques et discutés. Les bases d'une première approche de visualisation spatio-temporelle d'images TDM 3D+T de la prothèse valvulaire ont été proposés. Elle implique des techniques de rendu volumique et de compensation de mouvement. Son application à la valve native a aussi été envisagée. Les images scanner des bioprothèses aortiques nécessitent un traitement de débruitage et de réduction des artéfacts de façon à permettre le rehaussement des feuillets prothétiques. Les méthodes basées sticks semblent constituer une approche pertinente pour caractériser morphologiquement la dégénérescence des bioprothèses.The aim of the study was to assess the feasibility of CT based 3D analysis of degenerated aortic bioprostheses to make easier their morphological assessment. This could be helpful during regular follow-up and for case selection, improved planning and mapping of valve-in-valve procedure. The challenge was represented by leaflets enhancement because of highly noised CT images. Contrast-enhanced ECG-gated CT scan was performed in patients with degenerated aortic bioprostheses before reoperation (in-vivo images). Different methods for noise reduction were tested and proposed. 3D reconstruction of bioprostheses components was achieved using stick based region segmentation methods. After reoperation, segmentation methods were applied to CT images of the explanted prostheses (exvivo images). Noise reduction obtained by improved stick filter showed best results in terms of signal to noise ratio comparing to anisotropic diffusion filters. All segmentation methods applied to the best phase of in-vivo images allowed 3D bioprosthetic leaflets reconstruction. Explanted bioprostheses CT images were also processed and used as reference. Qualitative analysis revealed a good concordance between the in-vivo images and the bioprostheses alterations. Results from different methods were compared by means of volumetric criteria and discussed. A first approach for spatiotemporal visualization of 3D+T images of valve bioprosthesis has been proposed. Volume rendering and motion compensation techniques were applied to visualize different phases of CT data. Native valve was also considered. ECG-gated CT images of aortic bioprostheses need a preprocessing to reduce noise and artifacts in order to enhance prosthetic leaflets. Stick based methods seems to provide an interesting approach for the morphological characterization of degenerated bioprostheses.RENNES1-Bibl. électronique (352382106) / SudocSudocFranceF

    Traitement et exploration d'images TDM pour l'évaluation des bioprothèses valvulaires aortiques

    Get PDF
    Le but de cette étude est d évaluer la faisabilité de l analyse tomodensitométrique 3D des bioprothèses aortiques pour faciliter leur évaluation morphologique durant le suivi et d aider la sélection de cas et améliorer la planification d une procédure valvein-valve. Le challenge était représenté par le rehaussement des feuillets valvulaires, en raison d images très bruitées. Un angio-scanner synchronisé était réalisé chez des patients porteurs d une bioprotèses aortique dégénérée avant réintervention (images in-vivo). Différentes méthodes pour la réduction du bruit étaient proposées. La reconstruction tridimensionnelle des bioprothèses était réalisée en utilisant des méthodes de segmentation de régions par "sticks". Après réopération ces méthodes étaient appliquées aux images scanner des bioprothèses explantées (images ex-vivo) et utilisées comme référence. La réduction du bruit obtenue par le filtre stick modifié montrait meilleurs résultats en rapport signal/bruit en comparaison aux filtres de diffusion anisotropique. Toutes les méthodes de segmentation ont permis une reconstruction 3D des feuillets. L analyse qualitative a montré une bonne concordance entre les images obtenues in-vivo et les altérations des bioprothèses. Les résultats des différentes méthodes étaient comparés par critères volumétriques et discutés. Les bases d'une première approche de visualisation spatio-temporelle d'images TDM 3D+T de la prothèse valvulaire ont été proposés. Elle implique des techniques de rendu volumique et de compensation de mouvement. Son application à la valve native a aussi été envisagée. Les images scanner des bioprothèses aortiques nécessitent un traitement de débruitage et de réduction des artéfacts de façon à permettre le rehaussement des feuillets prothétiques. Les méthodes basées sticks semblent constituer une approche pertinente pour caractériser morphologiquement la dégénérescence des bioprothèses.The aim of the study was to assess the feasibility of CT based 3D analysis of degenerated aortic bioprostheses to make easier their morphological assessment. This could be helpful during regular follow-up and for case selection, improved planning and mapping of valve-in-valve procedure. The challenge was represented by leaflets enhancement because of highly noised CT images. Contrast-enhanced ECG-gated CT scan was performed in patients with degenerated aortic bioprostheses before reoperation (in-vivo images). Different methods for noise reduction were tested and proposed. 3D reconstruction of bioprostheses components was achieved using stick based region segmentation methods. After reoperation, segmentation methods were applied to CT images of the explanted prostheses (exvivo images). Noise reduction obtained by improved stick filter showed best results in terms of signal to noise ratio comparing to anisotropic diffusion filters. All segmentation methods applied to the best phase of in-vivo images allowed 3D bioprosthetic leaflets reconstruction. Explanted bioprostheses CT images were also processed and used as reference. Qualitative analysis revealed a good concordance between the in-vivo images and the bioprostheses alterations. Results from different methods were compared by means of volumetric criteria and discussed. A first approach for spatiotemporal visualization of 3D+T images of valve bioprosthesis has been proposed. Volume rendering and motion compensation techniques were applied to visualize different phases of CT data. Native valve was also considered. ECG-gated CT images of aortic bioprostheses need a preprocessing to reduce noise and artifacts in order to enhance prosthetic leaflets. Stick based methods seems to provide an interesting approach for the morphological characterization of degenerated bioprostheses.RENNES1-Bibl. électronique (352382106) / SudocSudocFranceF

    Aeronautical Engineering: A continuing bibliography with indexes (supplement 207)

    Get PDF
    This bibliography lists 484 reports, articles and other documents introduced into the NASA scientific and technical information system in November 1986
    • …
    corecore