25,391 research outputs found
Recommended from our members
Reachable Workspace and Proximal Function Measures for Quantifying Upper Limb Motion.
There are a lack of quantitative measures for clinically assessing upper limb function. Conventional biomechanical performance measures are restricted to specialist labs due to hardware cost and complexity, while the resulting measurements require specialists for analysis. Depth cameras are low cost and portable systems that can track surrogate joint positions. However, these motions may not be biologically consistent, which can result in noisy, inaccurate movements. This paper introduces a rigid body modelling method to enforce biological feasibility of the recovered motions. This method is evaluated on an existing depth camera assessment: the reachable workspace (RW) measure for assessing gross shoulder function. As a rigid body model is used, position estimates of new proximal targets can be added, resulting in a proximal function (PF) measure for assessing a subject's ability to touch specific body landmarks. The accuracy, and repeatability of these measures is assessed on ten asymptomatic subjects, with and without rigid body constraints. This analysis is performed both on a low-cost depth camera system and a gold-standard active motion capture system. The addition of rigid body constraints was found to improve accuracy and concordance of the depth camera system, particularly in lateral reaching movements. Both RW and PF measures were found to be feasible candidates for clinical assessment, with future analysis needed to determine their ability to detect changes within specific patient populations
Incorporation of the influences of kinematics parameters and joints tilting for the calibration of serial robotic manipulators
Serial robotic manipulators are calibrated to improve and restore their accuracy and repeatability. Kinematics parameters calibration of a robot reduces difference between the model of a robot in the controller and its actual mechanism to improve accuracy. Kinematics parameter’s error identification in the standard kinematics calibration has been configuration independent which does not consider the influence of kinematics parameter on robot tool pose accuracy for a given configuration. This research analyses the configuration dependent influences of kinematics parameters error on pose accuracy of a robot. Based on the effect of kinematics parameters, errors in the kinematics parameters are identified. Another issue is that current kinematics calibration models do not incorporate the joints tilting as a result of joint clearance, backlash, and flexibility, which is critical to the accuracy of serial robotic manipulators, and therefore compromises a pose accuracy. To address this issue which has not been carefully considered in the literature, this research suggested an approach to model configuration dependent joint tilting and presents a novel approach to encapsulate them in the calibration of serial robotic manipulators. The joint tilting along with the kinematics errors are identified and compensated in the kinematics model of the robot. Both conventional and proposed calibration approach are tested experimentally, and the calibration results are investigated to demonstrate the effectiveness of this research. Finally, the improvement in the trajectory tracking accuracy of the robot has been validated with the help of proposed low-cost measurement set-up.Thesis (M.Phil.) (Research by Publication) -- University of Adelaide, School of Mechanical Engineering , 201
Improving Foot-Mounted Inertial Navigation Through Real-Time Motion Classification
We present a method to improve the accuracy of a foot-mounted,
zero-velocity-aided inertial navigation system (INS) by varying estimator
parameters based on a real-time classification of motion type. We train a
support vector machine (SVM) classifier using inertial data recorded by a
single foot-mounted sensor to differentiate between six motion types (walking,
jogging, running, sprinting, crouch-walking, and ladder-climbing) and report
mean test classification accuracy of over 90% on a dataset with five different
subjects. From these motion types, we select two of the most common (walking
and running), and describe a method to compute optimal zero-velocity detection
parameters tailored to both a specific user and motion type by maximizing the
detector F-score. By combining the motion classifier with a set of optimal
detection parameters, we show how we can reduce INS position error during mixed
walking and running motion. We evaluate our adaptive system on a total of 5.9
km of indoor pedestrian navigation performed by five different subjects moving
along a 130 m path with surveyed ground truth markers.Comment: In Proceedings of the International Conference on Indoor Positioning
and Indoor Navigation (IPIN'17), Sapporo, Japan, Sep. 18-21, 201
Recommended from our members
Development of a Robotic Positioning and Tracking System for a Research Laboratory
Measurement of residual stress using neutron or synchrotron diffraction relies on the accurate alignment of the sample in relation to the gauge volume of the instrument. Automatic sample alignment can be achieved using kinematic models of the positioning system provided the relevant kinematic parameters are known, or can be determined, to a suitable accuracy.
The main problem addressed in this thesis is improving the repeatability and accuracy of the sample positioning for the strain scanning, through the use of techniques from robotic calibration theory to generate kinematic models of both off-the-shelf and custom-built positioning systems. The approach is illustrated using a positioning system in use on the ENGIN-X instrument at the UK’s ISIS pulsed neutron source comprising a traditional XYZΩ table augmented with a triple axis manipulator. Accuracies better than 100microns were achieved for this compound system. Although discussed here in terms of sample positioning systems these methods are entirely applicable to other moving instrument components such as beam shaping jaws and detectors.
Several factors could lead to inaccurate positioning on a neutron or synchrotron diffractometer. It is therefore essential to validate the accuracy of positioning especially during experiments which require a high level of accuracy. In this thesis, a stereo camera system is developed to monitor the sample and other moving parts of the diffractometer. The camera metrology system is designed to measure the positions of retroreflective markers attached to any object that is being monitored. A fully automated camera calibration procedure is developed with an emphasis on accuracy. The potential accuracy of this system is demonstrated and problems that limit accuracy are discussed. It is anticipated that the camera system would be used to correct the positioning system when the error is minimal or notify the user of the error when it is significant
Concurrent Segmentation and Localization for Tracking of Surgical Instruments
Real-time instrument tracking is a crucial requirement for various
computer-assisted interventions. In order to overcome problems such as specular
reflections and motion blur, we propose a novel method that takes advantage of
the interdependency between localization and segmentation of the surgical tool.
In particular, we reformulate the 2D instrument pose estimation as heatmap
regression and thereby enable a concurrent, robust and near real-time
regression of both tasks via deep learning. As demonstrated by our experimental
results, this modeling leads to a significantly improved performance than
directly regressing the tool position and allows our method to outperform the
state of the art on a Retinal Microsurgery benchmark and the MICCAI EndoVis
Challenge 2015.Comment: I. Laina and N. Rieke contributed equally to this work. Accepted to