77,400 research outputs found
CT Automated Exposure Control Using A Generalized Detectability Index
Purpose
Identifying an appropriate tube current setting can be challenging when using iterative reconstruction due to the varying relationship between spatial resolution, contrast, noise, and dose across different algorithms. This study developed and investigated the application of a generalized detectability index (d\u27gen) to determine the noise parameter to input to existing automated exposure control (AEC) systems to provide consistent image quality (IQ) across different reconstruction approaches. Methods
This study proposes a task‐based automated exposure control (AEC) method using a generalized detectability index (d\u27gen). The proposed method leverages existing AEC methods that are based on a prescribed noise level. The generalized d\u27gen metric is calculated using lookup tables of task‐based modulation transfer function (MTF) and noise power spectrum (NPS). To generate the lookup tables, the American College of Radiology CT accreditation phantom was scanned on a multidetector CT scanner (Revolution CT, GE Healthcare) at 120 kV and tube current varied manually from 20 to 240 mAs. Images were reconstructed using a reference reconstruction algorithm and four levels of an in‐house iterative reconstruction algorithm with different regularization strengths (IR1–IR4). The task‐based MTF and NPS were estimated from the measured images to create lookup tables of scaling factors that convert between d\u27gen and noise standard deviation. The performance of the proposed d\u27gen‐AEC method in providing a desired IQ level over a range of iterative reconstruction algorithms was evaluated using the American College of Radiology (ACR) phantom with elliptical shell and using a human reader evaluation on anthropomorphic phantom images. Results
The study of the ACR phantom with elliptical shell demonstrated reasonable agreement between the d\u27gen predicted by the lookup table and d\u27 measured in the images, with a mean absolute error of 15% across all dose levels and maximum error of 45% at the lowest dose level with the elliptical shell. For the anthropomorphic phantom study, the mean reader scores for images resulting from the d\u27gen‐AEC method were 3.3 (reference image), 3.5 (IR1), 3.6 (IR2), 3.5 (IR3), and 2.2 (IR4). When using the d\u27gen‐AEC method, the observers’ IQ scores for the reference reconstruction were statistical equivalent to the scores for IR1, IR2, and IR3 iterative reconstructions (P \u3e 0.35). The d\u27gen‐AEC method achieved this equivalent IQ at lower dose for the IR scans compared to the reference scans. Conclusions
A novel AEC method, based on a generalized detectability index, was investigated. The proposed method can be used with some existing AEC systems to derive the tube current profile for iterative reconstruction algorithms. The results provide preliminary evidence that the proposed d\u27gen‐AEC can produce similar IQ across different iterative reconstruction approaches at different dose levels
Streaming Video QoE Modeling and Prediction: A Long Short-Term Memory Approach
HTTP based adaptive video streaming has become a popular choice of streaming
due to the reliable transmission and the flexibility offered to adapt to
varying network conditions. However, due to rate adaptation in adaptive
streaming, the quality of the videos at the client keeps varying with time
depending on the end-to-end network conditions. Further, varying network
conditions can lead to the video client running out of playback content
resulting in rebuffering events. These factors affect the user satisfaction and
cause degradation of the user quality of experience (QoE). It is important to
quantify the perceptual QoE of the streaming video users and monitor the same
in a continuous manner so that the QoE degradation can be minimized. However,
the continuous evaluation of QoE is challenging as it is determined by complex
dynamic interactions among the QoE influencing factors. Towards this end, we
present LSTM-QoE, a recurrent neural network based QoE prediction model using a
Long Short-Term Memory (LSTM) network. The LSTM-QoE is a network of cascaded
LSTM blocks to capture the nonlinearities and the complex temporal dependencies
involved in the time varying QoE. Based on an evaluation over several publicly
available continuous QoE databases, we demonstrate that the LSTM-QoE has the
capability to model the QoE dynamics effectively. We compare the proposed model
with the state-of-the-art QoE prediction models and show that it provides
superior performance across these databases. Further, we discuss the state
space perspective for the LSTM-QoE and show the efficacy of the state space
modeling approaches for QoE prediction
Target-adaptive CNN-based pansharpening
We recently proposed a convolutional neural network (CNN) for remote sensing
image pansharpening obtaining a significant performance gain over the state of
the art. In this paper, we explore a number of architectural and training
variations to this baseline, achieving further performance gains with a
lightweight network which trains very fast. Leveraging on this latter property,
we propose a target-adaptive usage modality which ensures a very good
performance also in the presence of a mismatch w.r.t. the training set, and
even across different sensors. The proposed method, published online as an
off-the-shelf software tool, allows users to perform fast and high-quality
CNN-based pansharpening of their own target images on general-purpose hardware
- …