112 research outputs found

    Computerized Approaches for Retinal Microaneurysm Detection

    Get PDF
    The number of diabetic patients throughout the world is increasing with a very high rate. The patients suffering from long term diabetes have a very high risk of generating retinal disorder called Diabetic Retinopathy(DR). The disease is a complication of diabetes and may results in irreversible blindness to the patient. Early diagnosis and routine checkups by expert ophthalmologist possibly prevent the vision loss. But the number of people to be screen exceeds the number of experts, especially in rural areas. Thus the computerized screening systems are needed which will accurately screen the large amount of population and identify healthy and diseased people. Thus the workload on experts is reduced significantly. Microaneurysms(MA) are first recognizable signs of DR. Thus early detection of DR requires accurate detection of Microaneurysms. Computerized diagnosis insures reliable and accurate detection of MA's. The paper overviews the approaches for computerized detection of retinal Microaneurysms

    Automatic detection of microaneurysms in colour fundus images for diabetic retinopathy screening.

    Get PDF
    Regular eye screening is essential for the early detection and treatment of the diabetic retinopathy. This paper presents a novel automatic screening system for diabetic retinopathy that focuses on the detection of the earliest visible signs of retinopathy, which are microaneurysms. Microaneurysms are small dots on the retina, formed by ballooning out of a weak part of the capillary wall. The detection of the microaneurysms at an early stage is vital, and it is the first step in preventing the diabetic retinopathy. The paper first explores the existing systems and applications related to diabetic retinopathy screening, with a focus on the microaneurysm detection methods. The proposed decision support system consists of an automatic acquisition, screening and classification of diabetic retinopathy colour fundus images, which could assist in the detection and management of the diabetic retinopathy. Several feature extraction methods and the circular Hough transform have been employed in the proposed microaneurysm detection system, alongside the fuzzy histogram equalisation method. The latter method has been applied in the preprocessing stage of the diabetic retinopathy eye fundus images and provided improved results for detecting the microaneurysms

    Automatic Screening and Classification of Diabetic Retinopathy Eye Fundus Image

    Get PDF
    Diabetic Retinopathy (DR) is a disorder of the retinal vasculature. It develops to some degree in nearly all patients with long-standing diabetes mellitus and can result in blindness. Screening of DR is essential for both early detection and early treatment. This thesis aims to investigate automatic methods for diabetic retinopathy detection and subsequently develop an effective system for the detection and screening of diabetic retinopathy. The presented diabetic retinopathy research involves three development stages. Firstly, the thesis presents the development of a preliminary classification and screening system for diabetic retinopathy using eye fundus images. The research will then focus on the detection of the earliest signs of diabetic retinopathy, which are the microaneurysms. The detection of microaneurysms at an early stage is vital and is the first step in preventing diabetic retinopathy. Finally, the thesis will present decision support systems for the detection of diabetic retinopathy and maculopathy in eye fundus images. The detection of maculopathy, which are yellow lesions near the macula, is essential as it will eventually cause the loss of vision if the affected macula is not treated in time. An accurate retinal screening, therefore, is required to assist the retinal screeners to classify the retinal images effectively. Highly efficient and accurate image processing techniques must thus be used in order to produce an effective screening of diabetic retinopathy. In addition to the proposed diabetic retinopathy detection systems, this thesis will present a new dataset, and will highlight the dataset collection, the expert diagnosis process and the advantages of the new dataset, compared to other public eye fundus images datasets available. The new dataset will be useful to researchers and practitioners working in the retinal imaging area and would widely encourage comparative studies in the field of diabetic retinopathy research. It is envisaged that the proposed decision support system for clinical screening would greatly contribute to and assist the management and the detection of diabetic retinopathy. It is also hoped that the developed automatic detection techniques will assist clinicians to diagnose diabetic retinopathy at an early stage

    Detection of microaneurysms in retinal images using an ensemble classifier

    Get PDF
    This paper introduces, and reports on the performance of, a novel combination of algorithms for automated microaneurysm (MA) detection in retinal images. The presence of MAs in retinal images is a pathognomonic sign of Diabetic Retinopathy (DR) which is one of the leading causes of blindness amongst the working age population. An extensive survey of the literature is presented and current techniques in the field are summarised. The proposed technique first detects an initial set of candidates using a Gaussian Matched Filter and then classifies this set to reduce the number of false positives. A Tree Ensemble classifier is used with a set of 70 features (the most commons features in the literature). A new set of 32 MA groundtruth images (with a total of 256 labelled MAs) based on images from the MESSIDOR dataset is introduced as a public dataset for benchmarking MA detection algorithms. We evaluate our algorithm on this dataset as well as another public dataset (DIARETDB1 v2.1) and compare it against the best available alternative. Results show that the proposed classifier is superior in terms of eliminating false positive MA detection from the initial set of candidates. The proposed method achieves an ROC score of 0.415 compared to 0.2636 achieved by the best available technique. Furthermore, results show that the classifier model maintains consistent performance across datasets, illustrating the generalisability of the classifier and that overfitting does not occur

    Points of Interest and Visual Dictionaries for Automatic Retinal Lesion Detection

    Full text link

    Retinal Vessel Segmentation Using the 2-D Morlet Wavelet and Supervised Classification

    Get PDF
    We present a method for automated segmentation of the vasculature in retinal images. The method produces segmentations by classifying each image pixel as vessel or non-vessel, based on the pixel's feature vector. Feature vectors are composed of the pixel's intensity and continuous two-dimensional Morlet wavelet transform responses taken at multiple scales. The Morlet wavelet is capable of tuning to specific frequencies, thus allowing noise filtering and vessel enhancement in a single step. We use a Bayesian classifier with class-conditional probability density functions (likelihoods) described as Gaussian mixtures, yielding a fast classification, while being able to model complex decision surfaces and compare its performance with the linear minimum squared error classifier. The probability distributions are estimated based on a training set of labeled pixels obtained from manual segmentations. The method's performance is evaluated on publicly available DRIVE and STARE databases of manually labeled non-mydriatic images. On the DRIVE database, it achieves an area under the receiver operating characteristic (ROC) curve of 0.9598, being slightly superior than that presented by the method of Staal et al.Comment: 9 pages, 7 figures and 1 table. Accepted for publication in IEEE Trans Med Imag; added copyright notic
    corecore