2,151 research outputs found

    Automated image registration of cerebral digital subtraction angiography

    Get PDF
    Purpose: Our aim is to automatically align digital subtraction angiography (DSA) series, recorded before and after endovascular thrombectomy. Such alignment may enable quantification of procedural success. Methods: Firstly, we examine the inherent limitations for image registration, caused by the projective characteristics of DSA imaging, in a representative set of image pairs from thrombectomy procedures. Secondly, we develop and assess various image registration methods (SIFT, ORB). We assess these methods using manually annotated point correspondences for thrombectomy image pairs. Results: Linear transformations that account for scale differences are effective in aligning DSA sequences. Two anatomical landmarks can be reliably identified for registration using a U-net. Point-based registration using SIFT and ORB proves to be most effective for DSA registration and are applicable to recordings for all patient sub-types. Image-based techniques are less effective and did not refine the results of the best point-based registration method. Conclusion: We developed and assessed an automated image registration approach for cerebral DSA sequences, recorded before and after endovascular thrombectomy. Accurate results were obtained for approximately 85% of our image pairs.</p

    Feasibility of using Lodox to perform digital subtraction angiography

    Get PDF
    Bibliography: leaves 150-157.Many cases in trauma involve vessel imaging to determine integrity and the origin of lesions or blockages. Digital subtraction angiography (DSA) is a tool used to improve the clarity of the vessels being imaged for better and easier decision making in diagnostics and planning. Lodox, a low dose x-ray system developed by Debex (Pty) Ltd, a subsidiary of de Beers, was designed specifically for the trauma environment. It therefore follows that, if possible, a function so readily used in trauma, such as DSA, should be added to the imaging repertoire of an x-ray system designed for use in this environment. In this dissertation the feasibility of using Lodox to perform DSA is therefore explored. In doing so, the requirements of a trauma unit and the theory behind DSA were researched so as to obtain a better understanding into what would be required

    Advanced Algorithms for 3D Medical Image Data Fusion in Specific Medical Problems

    Get PDF
    Fúze obrazu je dnes jednou z nejběžnějších avšak stále velmi diskutovanou oblastí v lékařském zobrazování a hraje důležitou roli ve všech oblastech lékařské péče jako je diagnóza, léčba a chirurgie. V této dizertační práci jsou představeny tři projekty, které jsou velmi úzce spojeny s oblastí fúze medicínských dat. První projekt pojednává o 3D CT subtrakční angiografii dolních končetin. V práci je využito kombinace kontrastních a nekontrastních dat pro získání kompletního cévního stromu. Druhý projekt se zabývá fúzí DTI a T1 váhovaných MRI dat mozku. Cílem tohoto projektu je zkombinovat stukturální a funkční informace, které umožňují zlepšit znalosti konektivity v mozkové tkáni. Třetí projekt se zabývá metastázemi v CT časových datech páteře. Tento projekt je zaměřen na studium vývoje metastáz uvnitř obratlů ve fúzované časové řadě snímků. Tato dizertační práce představuje novou metodologii pro klasifikaci těchto metastáz. Všechny projekty zmíněné v této dizertační práci byly řešeny v rámci pracovní skupiny zabývající se analýzou lékařských dat, kterou vedl pan Prof. Jiří Jan. Tato dizertační práce obsahuje registrační část prvního a klasifikační část třetího projektu. Druhý projekt je představen kompletně. Další část prvního a třetího projektu, obsahující specifické předzpracování dat, jsou obsaženy v disertační práci mého kolegy Ing. Romana Petera.Image fusion is one of today´s most common and still challenging tasks in medical imaging and it plays crucial role in all areas of medical care such as diagnosis, treatment and surgery. Three projects crucially dependent on image fusion are introduced in this thesis. The first project deals with the 3D CT subtraction angiography of lower limbs. It combines pre-contrast and contrast enhanced data to extract the blood vessel tree. The second project fuses the DTI and T1-weighted MRI brain data. The aim of this project is to combine the brain structural and functional information that purvey improved knowledge about intrinsic brain connectivity. The third project deals with the time series of CT spine data where the metastases occur. In this project the progression of metastases within the vertebrae is studied based on fusion of the successive elements of the image series. This thesis introduces new methodology of classifying metastatic tissue. All the projects mentioned in this thesis have been solved by the medical image analysis group led by Prof. Jiří Jan. This dissertation concerns primarily the registration part of the first project and the classification part of the third project. The second project is described completely. The other parts of the first and third project, including the specific preprocessing of the data, are introduced in detail in the dissertation thesis of my colleague Roman Peter, M.Sc.

    Energy Subtraction Methods as an Alternative to Conventional X-Ray Angiography

    Get PDF
    Digital subtraction angiography (DSA) is a technique that is widely used to enhance the visibility of small vessels obscured by background structures by subtracting a mask and contrast image. However, DSA is generally unsuccessful for imaging the heart due to the motion that occurs between mask and contrasted images which cause motion artifacts. An alternative approach known as energy subtraction angiography (ESA) exploits the iodine k-edge by acquiring contrast images with a low and high kV in rapid succession to bring the benefits of DSA without motion artifacts. However, it was concluded that image quality for ESA could not compete with DSA, and the approach was abandoned. In our work we show that conclusions about iodine SNR for ESA were based on limitations of early technical components that are no longer relevant. The goals of this thesis were to: 1) develop a theoretical model of iodine SNR that is independent of technology for DSA and ESA; 2) optimize the iodine SNR for ESA; 3) image ESA in an anthropomorphic phantom. It is concluded that, when these conditions are satisfied, ESA iodine SNR equal to that of DSA for low iodine mass loadings (artery sizes) for the same patient entrance exposure, and therefore may provide alternatives to DSA in situations where motion artifacts are expected to render a study as non-diagnostic, such as in coronary applications. In the future this will have important applications for subtraction imaging of the coronary arteries and other vessels where stenosis is vital to patient health

    Digital data registration and differencing compression system

    Get PDF
    A process is disclosed for x ray registration and differencing which results in more efficient compression. Differencing of registered modeled subject image with a modeled reference image forms a differenced image for compression with conventional compression algorithms. Obtention of a modeled reference image includes modeling a relatively unrelated standard reference image upon a three-dimensional model, which three-dimensional model is also used to model the subject image for obtaining the modeled subject image. The registration process of the modeled subject image and modeled reference image translationally correlates such modeled images for resulting correlation thereof in spatial and spectral dimensions. Prior to compression, a portion of the image falling outside a designated area of interest may be eliminated, for subsequent replenishment with a standard reference image. The compressed differenced image may be subsequently transmitted and/or stored, for subsequent decompression and addition to a standard reference image so as to form a reconstituted or approximated subject image at either a remote location and/or at a later moment in time. Overall effective compression ratios of 100:1 are possible for thoracic x ray digital images
    corecore