982 research outputs found

    The potential of additive manufacturing in the smart factory industrial 4.0: A review

    Get PDF
    Additive manufacturing (AM) or three-dimensional (3D) printing has introduced a novel production method in design, manufacturing, and distribution to end-users. This technology has provided great freedom in design for creating complex components, highly customizable products, and efficient waste minimization. The last industrial revolution, namely industry 4.0, employs the integration of smart manufacturing systems and developed information technologies. Accordingly, AM plays a principal role in industry 4.0 thanks to numerous benefits, such as time and material saving, rapid prototyping, high efficiency, and decentralized production methods. This review paper is to organize a comprehensive study on AM technology and present the latest achievements and industrial applications. Besides that, this paper investigates the sustainability dimensions of the AM process and the added values in economic, social, and environment sections. Finally, the paper concludes by pointing out the future trend of AM in technology, applications, and materials aspects that have the potential to come up with new ideas for the future of AM explorations

    Distributed brain co-processor for tracking spikes, seizures and behaviour during electrical brain stimulation

    Get PDF
    Early implantable epilepsy therapy devices provided open-loop electrical stimulation without brain sensing, computing, or an interface for synchronized behavioural inputs from patients. Recent epilepsy stimulation devices provide brain sensing but have not yet developed analytics for accurately tracking and quantifying behaviour and seizures. Here we describe a distributed brain co-processor providing an intuitive bi-directional interface between patient, implanted neural stimulation and sensing device, and local and distributed computing resources. Automated analysis of continuous streaming electrophysiology is synchronized with patient reports using a handheld device and integrated with distributed cloud computing resources for quantifying seizures, interictal epileptiform spikes and patient symptoms during therapeutic electrical brain stimulation. The classification algorithms for interictal epileptiform spikes and seizures were developed and parameterized using long-term ambulatory data from nine humans and eight canines with epilepsy, and then implemented prospectively in out-of-sample testing in two pet canines and four humans with drug-resistant epilepsy living in their natural environments. Accurate seizure diaries are needed as the primary clinical outcome measure of epilepsy therapy and to guide brain-stimulation optimization. The brain co-processor system described here enables tracking interictal epileptiform spikes, seizures and correlation with patient behavioural reports. In the future, correlation of spikes and seizures with behaviour will allow more detailed investigation of the clinical impact of spikes and seizures on patients

    Security Applications for Converging Technologies - Impact on the Constitutional State and the Legal order

    Get PDF
    In this study we investigate the impact of converging technologies on legal practice and criminology in a forward looking study intended for practitioners and policy makers in the field of legislation, crime prevention, and law enforcement. We look at a 15 years timeframe and discuss the scientific and technical progress in various domains as well as the ethical, legal, and policy dilemmas involved.

    Continuous-time acquisition of biosignals using a charge-based ADC topology

    Get PDF
    This paper investigates continuous-time (CT) signal acquisition as an activity-dependent and nonuniform sampling alternative to conventional fixed-rate digitisation. We demonstrate the applicability to biosignal representation by quantifying the achievable bandwidth saving by nonuniform quantisation to commonly recorded biological signal fragments allowing a compression ratio of ≈5 and 26 when applied to electrocardiogram and extracellular action potential signals, respectively. We describe several desirable properties of CT sampling, including bandwidth reduction, elimination/reduction of quantisation error, and describe its impact on aliasing. This is followed by demonstration of a resource-efficient hardware implementation. We propose a novel circuit topology for a charge-based CT analogue-to-digital converter that has been optimized for the acquisition of neural signals. This has been implemented in a commercially available 0.35 μm CMOS technology occupying a compact footprint of 0.12 mm 2 . Silicon verified measurements demonstrate an 8-bit resolution and a 4 kHz bandwidth with static power consumption of 3.75 μW from a 1.5 V supply. The dynamic power dissipation is completely activity-dependent, requiring 1.39 pJ energy per conversion

    Research and Education in Computational Science and Engineering

    Get PDF
    Over the past two decades the field of computational science and engineering (CSE) has penetrated both basic and applied research in academia, industry, and laboratories to advance discovery, optimize systems, support decision-makers, and educate the scientific and engineering workforce. Informed by centuries of theory and experiment, CSE performs computational experiments to answer questions that neither theory nor experiment alone is equipped to answer. CSE provides scientists and engineers of all persuasions with algorithmic inventions and software systems that transcend disciplines and scales. Carried on a wave of digital technology, CSE brings the power of parallelism to bear on troves of data. Mathematics-based advanced computing has become a prevalent means of discovery and innovation in essentially all areas of science, engineering, technology, and society; and the CSE community is at the core of this transformation. However, a combination of disruptive developments---including the architectural complexity of extreme-scale computing, the data revolution that engulfs the planet, and the specialization required to follow the applications to new frontiers---is redefining the scope and reach of the CSE endeavor. This report describes the rapid expansion of CSE and the challenges to sustaining its bold advances. The report also presents strategies and directions for CSE research and education for the next decade.Comment: Major revision, to appear in SIAM Revie

    Advanced Applications of Rapid Prototyping Technology in Modern Engineering

    Get PDF
    Rapid prototyping (RP) technology has been widely known and appreciated due to its flexible and customized manufacturing capabilities. The widely studied RP techniques include stereolithography apparatus (SLA), selective laser sintering (SLS), three-dimensional printing (3DP), fused deposition modeling (FDM), 3D plotting, solid ground curing (SGC), multiphase jet solidification (MJS), laminated object manufacturing (LOM). Different techniques are associated with different materials and/or processing principles and thus are devoted to specific applications. RP technology has no longer been only for prototype building rather has been extended for real industrial manufacturing solutions. Today, the RP technology has contributed to almost all engineering areas that include mechanical, materials, industrial, aerospace, electrical and most recently biomedical engineering. This book aims to present the advanced development of RP technologies in various engineering areas as the solutions to the real world engineering problems

    Biophysical modeling of a cochlear implant system: progress on closed-loop design using a novel patient-specific evaluation platform

    Get PDF
    The modern cochlear implant is one of the most successful neural stimulation devices, which partially mimics the workings of the auditory periphery. In the last few decades it has created a paradigm shift in hearing restoration of the deaf population, which has led to more than 324,000 cochlear implant users today. Despite its great success there is great disparity in patient outcomes without clear understanding of the aetiology of this variance in implant performance. Furthermore speech recognition in adverse conditions or music appreciation is still not attainable with today's commercial technology. This motivates the research for the next generation of cochlear implants that takes advantage of recent developments in electronics, neuroscience, nanotechnology, micro-mechanics, polymer chemistry and molecular biology to deliver high fidelity sound. The main difficulties in determining the root of the problem in the cases where the cochlear implant does not perform well are two fold: first there is not a clear paradigm on how the electrical stimulation is perceived as sound by the brain, and second there is limited understanding on the plasticity effects, or learning, of the brain in response to electrical stimulation. These significant knowledge limitations impede the design of novel cochlear implant technologies, as the technical specifications that can lead to better performing implants remain undefined. The motivation of the work presented in this thesis is to compare and contrast the cochlear implant neural stimulation with the operation of the physiological healthy auditory periphery up to the level of the auditory nerve. As such design of novel cochlear implant systems can become feasible by gaining insight on the question `how well does a specific cochlear implant system approximate the healthy auditory periphery?' circumventing the necessity of complete understanding of the brain's comprehension of patterned electrical stimulation delivered from a generic cochlear implant device. A computational model, termed Digital Cochlea Stimulation and Evaluation Tool (‘DiCoStET’) has been developed to provide an objective estimate of cochlear implant performance based on neuronal activation measures, such as vector strength and average activation. A patient-specific cochlea 3D geometry is generated using a model derived by a single anatomical measurement from a patient, using non-invasive high resolution computed tomography (HRCT), and anatomically invariant human metrics and relations. Human measurements of the neuron route within the inner ear enable an innervation pattern to be modelled which joins the space from the organ of Corti to the spiral ganglion subsequently descending into the auditory nerve bundle. An electrode is inserted in the cochlea at a depth that is determined by the user of the tool. The geometric relation between the stimulation sites on the electrode and the spiral ganglion are used to estimate an activating function that will be unique for the specific patient's cochlear shape and electrode placement. This `transfer function', so to speak, between electrode and spiral ganglion serves as a `digital patient' for validating novel cochlear implant systems. The novel computational tool is intended for use by bioengineers, surgeons, audiologists and neuroscientists alike. In addition to ‘DiCoStET’ a second computational model is presented in this thesis aiming at enhancing the understanding of the physiological mechanisms of hearing, specifically the workings of the auditory synapse. The purpose of this model is to provide insight on the sound encoding mechanisms of the synapse. A hypothetical mechanism is suggested in the release of neurotransmitter vesicles that permits the auditory synapse to encode temporal patterns of sound separately from sound intensity. DiCoStET was used to examine the performance of two different types of filters used for spectral analysis in the cochlear implant system, the Gammatone type filter and the Butterworth type filter. The model outputs suggest that the Gammatone type filter performs better than the Butterworth type filter. Furthermore two stimulation strategies, the Continuous Interleaved Stimulation (CIS) and Asynchronous Interleaved Stimulation (AIS) have been compared. The estimated neuronal stimulation spatiotemporal patterns for each strategy suggest that the overall stimulation pattern is not greatly affected by the temporal sequence change. However the finer detail of neuronal activation is different between the two strategies, and when compared to healthy neuronal activation patterns the conjecture is made that the sequential stimulation of CIS hinders the transmission of sound fine structure information to the brain. The effect of the two models developed is the feasibility of collaborative work emanating from various disciplines; especially electrical engineering, auditory physiology and neuroscience for the development of novel cochlear implant systems. This is achieved by using the concept of a `digital patient' whose artificial neuronal activation is compared to a healthy scenario in a computationally efficient manner to allow practical simulation times.Open Acces
    • …
    corecore