10 research outputs found

    The Effect of an Occluder on the Accuracy of Depth Perception in Optical See-Through Augmented Reality

    Get PDF
    Three experiments were conducted to study the effect of an occluder on the accuracy of nearield depth perception in optical-see-through augmented reality (AR). The first experiment was a duplicate experiment of the one in Edwards et al. [2004]. We found more accurate results than Edwards et al.’s work and did not find the occluder’s main effect or its two-way interaction effect with distance on the accuracy of observers’ depth matching. The second experiment was an updated version of the first one using a within-subject design and a more accurate calibration method. The results were that errors ranged from –5 to 3 mm when the occluder was present, –3 to 2 mm when the occluder was absent, and observers judged the virtual object to be closer after the presentation of the occluder. The third experiment was conducted on three subjects who were depth perception researchers. The result showed significant individual effects

    Veröffentlichungen und Vorträge 2003 der Mitgleider der Fakultät für Informatik

    Get PDF

    Veröffentlichungen und Vorträge 2002 der Mitglieder der Fakultät für Informatik

    Get PDF

    Veröffentlichungen und Vorträge 2001 der Mitglieder der Fakultät für Informatik

    Get PDF

    INPRES (intraoperative presentation of surgical planning and simulation results) – augmented reality for craniofacial surgery

    No full text
    In this paper we present recent developments and pre-clinical validation results of our approach for augmented reality (AR, for short) in craniofacial surgery. A commercial Sony Glasstron display is used for optical see-through overlay of surgical planning and simulation results with a patient inside the operation room (OR). For the tracking of the glasses, of the patient and of various medical instruments an NDI Polaris system is used as standard solution. A complementary inside-out navigation approach has been realized with a panoramic camera. This device is mounted on the head of the surgeon for tracking of fiducials placed on the walls of the OR. Further tasks described include the calibration of the head-mounted display (HMD), the registration of virtual objects with the real world and the detection of occlusions in the object overlay with help of two miniature CCD cameras. The evaluation of our work took place in the laboratory environment and showed promising results. Future work will concentrate on the optimization of the technical features of the prototype and on the development of a system for everyday clinical use
    corecore