53 research outputs found

    Distributed multivariate regression with unknown noise covariance in the presence of outliers: an MDL approach

    Get PDF
    We consider the problem of estimating the coefficients in a multivariable linear model by means of a wireless sensor network which may be affected by anomalous measurements. The noise covariance matrices at the different sensors are assumed unknown. Treating outlying samples, and their support, as additional nuisance parameters, the Maximum Likelihood estimate is investigated, with the number of outliers being estimated according to the Minimum Description Length principle. A distributed implementation based on iterative consensus techniques is then proposed, and it is shown effective for managing outliers in the data.Peer ReviewedPostprint (author's final draft

    A Survey of Recent Advances in Particle Filters and Remaining Challenges for Multitarget Tracking

    Get PDF
    [EN]We review some advances of the particle filtering (PF) algorithm that have been achieved in the last decade in the context of target tracking, with regard to either a single target or multiple targets in the presence of false or missing data. The first part of our review is on remarkable achievements that have been made for the single-target PF from several aspects including importance proposal, computing efficiency, particle degeneracy/impoverishment and constrained/multi-modal systems. The second part of our review is on analyzing the intractable challenges raised within the general multitarget (multi-sensor) tracking due to random target birth and termination, false alarm, misdetection, measurement-to-track (M2T) uncertainty and track uncertainty. The mainstream multitarget PF approaches consist of two main classes, one based on M2T association approaches and the other not such as the finite set statistics-based PF. In either case, significant challenges remain due to unknown tracking scenarios and integrated tracking management

    Bayesian Bacterial Detection Using Irregularly Sampled Optical Endomicroscopy Images

    Get PDF
    Pneumonia is a major cause of morbidity and mortality of patients in intensive care. Rapid determination of the presence and gram status of the pathogenic bacteria in the distal lung may enable a more tailored treatment regime. Optical Endomicroscopy (OEM) is an emerging medical imaging platform with preclinical and clinical utility. Pulmonary OEM via multi-core fibre bundles has the potential to provide in vivo, in situ, fluorescent molecular signatures of the causes of infection and inflammation. This paper presents a Bayesian approach for bacterial detection in OEM images. The model considered assumes that the observed pixel fluorescence is a linear combination of the actual intensity value associated with tissues or background, corrupted by additive Gaussian noise and potentially by an additional sparse outlier term modelling anomalies (bacteria). The bacteria detection problem is formulated in a Bayesian framework and prior distributions are assigned to the unknown model parameters. A Markov chain Monte Carlo algorithm based on a partially collapsed Gibbs sampler is used to sample the posterior distribution of the unknown parameters. The proposed algorithm is first validated by simulations conducted using synthetic datasets for which good performance is obtained. Analysis is then conducted using two ex vivo lung datasets in which fluorescently labelled bacteria are present in the distal lung. A good correlation between bacteria counts identified by a trained clinician and those of the proposed method, which detects most of the manually annotated regions, is observed

    Velocity ambiguity mitigation of off-grid range migrating targets via Bayesian sparse recovery

    Get PDF
    Within the scope of sparse signal representation, we consider the problem of velocity ambiguity mitigation for wideband radar signal. We present a Bayesian robust algorithm based on a new sparsifying dictionary suited for range-migrating targets possibly straddling range-velocity bins. Numerical simulations on experimental data demonstrate the ability of the proposed algorithm in mitigating velocity ambiguity

    Performance Bounds for Parameter Estimation under Misspecified Models: Fundamental findings and applications

    Full text link
    Inferring information from a set of acquired data is the main objective of any signal processing (SP) method. In particular, the common problem of estimating the value of a vector of parameters from a set of noisy measurements is at the core of a plethora of scientific and technological advances in the last decades; for example, wireless communications, radar and sonar, biomedicine, image processing, and seismology, just to name a few. Developing an estimation algorithm often begins by assuming a statistical model for the measured data, i.e. a probability density function (pdf) which if correct, fully characterizes the behaviour of the collected data/measurements. Experience with real data, however, often exposes the limitations of any assumed data model since modelling errors at some level are always present. Consequently, the true data model and the model assumed to derive the estimation algorithm could differ. When this happens, the model is said to be mismatched or misspecified. Therefore, understanding the possible performance loss or regret that an estimation algorithm could experience under model misspecification is of crucial importance for any SP practitioner. Further, understanding the limits on the performance of any estimator subject to model misspecification is of practical interest. Motivated by the widespread and practical need to assess the performance of a mismatched estimator, the goal of this paper is to help to bring attention to the main theoretical findings on estimation theory, and in particular on lower bounds under model misspecification, that have been published in the statistical and econometrical literature in the last fifty years. Secondly, some applications are discussed to illustrate the broad range of areas and problems to which this framework extends, and consequently the numerous opportunities available for SP researchers.Comment: To appear in the IEEE Signal Processing Magazin

    Quantifying Reliable Walking Activity with a Wearable Device in Aged Residential Care: How Many Days Are Enough?

    Get PDF
    Strong associations exist between quality of life and physical activity for those living in aged residential care (ARC). Suitable and reliable tools are required to quantify physical activity for descriptive and evaluative purposes. We calculated the number of days required for reliable walking outcomes indicative of physical activity in an ARC population using a trunk-worn device. ARC participants (n = 257) wore the device for up to 7 days. Reasons for data loss were also recorded. The volume, pattern, and variability of walking was calculated. For 197 participants who wore the device for at least 3 days, linear mixed models determined the impact of week structure and number of days required to achieve reliable outcomes, collectively and then stratified by care level. The average days recorded by the wearable device was 5.2 days. Day of the week did not impact walking activity. Depending on the outcome and level of care, 2–5 days was sufficient for reliable estimates. This study provides informative evidence for future studies aiming to use a wearable device located on the trunk to quantify physical activity walking out in the ARC population

    Refined Multiscale Fuzzy Entropy to Analyse Post-Exercise Cardiovascular Response in Older Adults With Orthostatic Intolerance

    Full text link
    [EN] Orthostatic intolerance syndrome occurs when the autonomic nervous system is incapacitated and fails to respond to the demands associated with the upright position. Assessing this syndrome among the elderly population is important in order to prevent falls. However, this problem is still challenging. The goal of this work was to determine the relationship between orthostatic intolerance (OI) and the cardiovascular response to exercise from the analysis of heart rate and blood pressure. More specifically, the behavior of these cardiovascular variables was evaluated in terms of refined composite multiscale fuzzy entropy (RCMFE), measured at different scales. The dataset was composed by 65 older subjects, 44.6% (n = 29) were OI symptomatic and 55.4% (n = 36) were not. Insignificant differences were found in age and gender between symptomatic and asymptomatic OI participants. When heart rate was evaluated, higher differences between groups were observed during the recovery period immediately after exercise. With respect to the blood pressure and other hemodynamic parameters, most significant results were obtained in the post-exercise stage. In any case, the symptomatic OI group exhibited higher irregularity in the measured parameters, as higher RCMFE levels in all time scales were obtained. This information could be very helpful for a better understanding of cardiovascular instability, as well as to recognize risk factors for falls and impairment of functional status.This research was funded by the Ministerio de Economia y Competitividad from the Spanish Government, through its research program Programa Estatal de I+D+i Orientada a los Retos de la Sociedad, grant number DPI2015-70821-R.Hortelano, M.; Reilly, R.; Castells, F.; CervigĂłn, R. (2018). Refined Multiscale Fuzzy Entropy to Analyse Post-Exercise Cardiovascular Response in Older Adults With Orthostatic Intolerance. Entropy. 20(11):1-12. https://doi.org/10.3390/e20110860S112201

    Toward a regulatory qualification of real-world mobility performance biomarkers in Parkinson’s patients using Digital Mobility Outcomes

    Get PDF
    Wearable inertial sensors can be used to monitor mobility in real-world settings over extended periods. Although these technologies are widely used in human movement research, they have not yet been qualified by drug regulatory agencies for their use in regulatory drug trials. This is because the first generation of these sensors was unreliable when used on slow-walking subjects. However, intense research in this area is now offering a new generation of algorithms to quantify Digital Mobility Outcomes so accurate they may be considered as biomarkers in regulatory drug trials. This perspective paper summarises the work in the Mobilise-D consortium around the regulatory qualification of the use of wearable sensors to quantify real-world mobility performance in patients affected by Parkinson’s Disease. The paper describes the qualification strategy and both the technical and clinical validation plans, which have recently received highly supportive qualification advice from the European Medicines Agency. The scope is to provide detailed guidance for the preparation of similar qualification submissions to broaden the use of real-world mobility assessment in regulatory drug trials
    • 

    corecore