127 research outputs found

    Comfort-Centered Design of a Lightweight and Backdrivable Knee Exoskeleton

    Full text link
    This paper presents design principles for comfort-centered wearable robots and their application in a lightweight and backdrivable knee exoskeleton. The mitigation of discomfort is treated as mechanical design and control issues and three solutions are proposed in this paper: 1) a new wearable structure optimizes the strap attachment configuration and suit layout to ameliorate excessive shear forces of conventional wearable structure design; 2) rolling knee joint and double-hinge mechanisms reduce the misalignment in the sagittal and frontal plane, without increasing the mechanical complexity and inertia, respectively; 3) a low impedance mechanical transmission reduces the reflected inertia and damping of the actuator to human, thus the exoskeleton is highly-backdrivable. Kinematic simulations demonstrate that misalignment between the robot joint and knee joint can be reduced by 74% at maximum knee flexion. In experiments, the exoskeleton in the unpowered mode exhibits 1.03 Nm root mean square (RMS) low resistive torque. The torque control experiments demonstrate 0.31 Nm RMS torque tracking error in three human subjects.Comment: 8 pages, 16figures, Journa

    Effects of a soft robotic exosuit on the quality and speed of overground walking depends on walking ability after stroke

    Get PDF
    \ua9 2023, BioMed Central Ltd., part of Springer Nature.Background: Soft robotic exosuits can provide partial dorsiflexor and plantarflexor support in parallel with paretic muscles to improve poststroke walking capacity. Previous results indicate that baseline walking ability may impact a user’s ability to leverage the exosuit assistance, while the effects on continuous walking, walking stability, and muscle slacking have not been evaluated. Here we evaluated the effects of a portable ankle exosuit during continuous comfortable overground walking in 19 individuals with chronic hemiparesis. We also compared two speed-based subgroups (threshold: 0.93 m/s) to address poststroke heterogeneity. Methods: We refined a previously developed portable lightweight soft exosuit to support continuous overground walking. We compared five minutes of continuous walking in a laboratory with the exosuit to walking without the exosuit in terms of ground clearance, foot landing and propulsion, as well as the energy cost of transport, walking stability and plantarflexor muscle slacking. Results: Exosuit assistance was associated with improvements in the targeted gait impairments: 22% increase in ground clearance during swing, 5\ub0 increase in foot-to-floor angle at initial contact, and 22% increase in the center-of-mass propulsion during push-off. The improvements in propulsion and foot landing contributed to a 6.7% (0.04 m/s) increase in walking speed (R 2 = 0.82). This enhancement in gait function was achieved without deterioration in muscle effort, stability or cost of transport. Subgroup analyses revealed that all individuals profited from ground clearance support, but slower individuals leveraged plantarflexor assistance to improve propulsion by 35% to walk 13% faster, while faster individuals did not change either. Conclusions: The immediate restorative benefits of the exosuit presented here underline its promise for rehabilitative gait training in poststroke individuals

    Continuous sweep versus discrete step protocols for studying effects of wearable robot assistance magnitude

    Get PDF
    Background: Different groups developed wearable robots for walking assistance, but there is still a need for methods to quickly tune actuation parameters for each robot and population or sometimes even for individual users. Protocols where parameters are held constant for multiple minutes have traditionally been used for evaluating responses to parameter changes such as metabolic rate or walking symmetry. However, these discrete protocols are time-consuming. Recently, protocols have been proposed where a parameter is changed in a continuous way. The aim of the present study was to compare effects of continuously varying assistance magnitude with a soft exosuit against discrete step conditions. Methods: Seven participants walked on a treadmill wearing a soft exosuit that assists plantarflexion and hip flexion. In Continuous-up, peak exosuit ankle moment linearly increased from approximately 0 to 38% of biological moment over 10 min. Continuous-down was the opposite. In Discrete, participants underwent five periods of 5 min with steady peak moment levels distributed over the same range as Continuous-up and Continuous-down. We calculated metabolic rate for the entire Continuous-up and Continuous-down conditions and the last 2 min of each Discrete force level. We compared kinematics, kinetics and metabolic rate between conditions by curve fitting versus peak moment. Results: Reduction in metabolic rate compared to Powered-off was smaller in Continuous-up than in Continuousdown at most peak moment levels, due to physiological dynamics causing metabolic measurements in Continuousup and Continuous-down to lag behind the values expected during steady-state testing. When evaluating the average slope of metabolic reduction over the entire peak moment range there was no significant difference between Continuous-down and Discrete. Attempting to correct the lag in metabolics by taking the average of Continuous-up and Continuous-down removed all significant differences versus Discrete. For kinematic and kinetic parameters, there were no differences between all conditions. Conclusions: The finding that there were no differences in biomechanical parameters between all conditions suggests that biomechanical parameters can be recorded with the shortest protocol condition (i.e. single Continuous directions). The shorter time and higher resolution data of continuous sweep protocols hold promise for the future study of human interaction with wearable robots

    Lower-Limb Exosuits for Rehabilitation or Assistance of Human Movement: A Systematic Review

    Get PDF
    Background: The aim of this review is to provide a comprehensive overview of the technological state-of-the-art of exosuits and the clinical results obtained when applied to users with mobility impairment. Methods: Searches are carried out in the COCHRANE, PubMed, IEEE Xplore and MEDLINE databases. Titles, abstracts and full texts are screened for inclusion criteria. Technological and clinical data are extracted. The quality of the studies is evaluated via a study quality assessment tool. Results: 19 studies are identified as relevant. Active (47%) and passive exosuits (53%) are used. Most are used untethered (84%), accommodating the demand of mobility. No study reports power consumption, which is important for dimensioning power systems. Fields of applications are post-stroke (79%), osteoarthritis (16%) and post-trauma (5%). Mostly the ankle joint is addressed (57%), while less studies address multiple joints (21%). The outcomes of clinical evaluations of lower-limb exosuits with patients suffering from mobility impairments are positive in the correction of gait pattern and reducing metabolic energy consumption during hemiparetic walking. Conclusions: Lower-limb exosuits for clinical applications are still facing technological challenges. Fields of application are limited to stroke, osteoarthritis and trauma. While clinical outcomes are overall positive, improvements in the study protocols are suggested.Peer ReviewedObjectius de Desenvolupament Sostenible::3 - Salut i BenestarPostprint (published version