45 research outputs found

    Book of Abstracts 15th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering and 3rd Conference on Imaging and Visualization

    Get PDF
    In this edition, the two events will run together as a single conference, highlighting the strong connection with the Taylor & Francis journals: Computer Methods in Biomechanics and Biomedical Engineering (John Middleton and Christopher Jacobs, Eds.) and Computer Methods in Biomechanics and Biomedical Engineering: Imaging and Visualization (JoãoManuel R.S. Tavares, Ed.). The conference has become a major international meeting on computational biomechanics, imaging andvisualization. In this edition, the main program includes 212 presentations. In addition, sixteen renowned researchers will give plenary keynotes, addressing current challenges in computational biomechanics and biomedical imaging. In Lisbon, for the first time, a session dedicated to award the winner of the Best Paper in CMBBE Journal will take place. We believe that CMBBE2018 will have a strong impact on the development of computational biomechanics and biomedical imaging and visualization, identifying emerging areas of research and promoting the collaboration and networking between participants. This impact is evidenced through the well-known research groups, commercial companies and scientific organizations, who continue to support and sponsor the CMBBE meeting series. In fact, the conference is enriched with five workshops on specific scientific topics and commercial software.info:eu-repo/semantics/draf

    PRELIMINARY FINDINGS OF A POTENZIATED PIEZOSURGERGICAL DEVICE AT THE RABBIT SKULL

    Get PDF
    The number of available ultrasonic osteotomes has remarkably increased. In vitro and in vivo studies have revealed differences between conventional osteotomes, such as rotating or sawing devices, and ultrasound-supported osteotomes (Piezosurgery®) regarding the micromorphology and roughness values of osteotomized bone surfaces. Objective: the present study compares the micro-morphologies and roughness values of osteotomized bone surfaces after the application of rotating and sawing devices, Piezosurgery Medical® and Piezosurgery Medical New Generation Powerful Handpiece. Methods: Fresh, standard-sized bony samples were taken from a rabbit skull using the following osteotomes: rotating and sawing devices, Piezosurgery Medical® and a Piezosurgery Medical New Generation Powerful Handpiece. The required duration of time for each osteotomy was recorded. Micromorphologies and roughness values to characterize the bone surfaces following the different osteotomy methods were described. The prepared surfaces were examined via light microscopy, environmental surface electron microscopy (ESEM), transmission electron microscopy (TEM), confocal laser scanning microscopy (CLSM) and atomic force microscopy. The selective cutting of mineralized tissues while preserving adjacent soft tissue (dura mater and nervous tissue) was studied. Bone necrosis of the osteotomy sites and the vitality of the osteocytes near the sectional plane were investigated, as well as the proportion of apoptosis or cell degeneration. Results and Conclusions: The potential positive effects on bone healing and reossification associated with different devices were evaluated and the comparative analysis among the different devices used was performed, in order to determine the best osteotomes to be employed during cranio-facial surgery

    Advanced Applications of Rapid Prototyping Technology in Modern Engineering

    Get PDF
    Rapid prototyping (RP) technology has been widely known and appreciated due to its flexible and customized manufacturing capabilities. The widely studied RP techniques include stereolithography apparatus (SLA), selective laser sintering (SLS), three-dimensional printing (3DP), fused deposition modeling (FDM), 3D plotting, solid ground curing (SGC), multiphase jet solidification (MJS), laminated object manufacturing (LOM). Different techniques are associated with different materials and/or processing principles and thus are devoted to specific applications. RP technology has no longer been only for prototype building rather has been extended for real industrial manufacturing solutions. Today, the RP technology has contributed to almost all engineering areas that include mechanical, materials, industrial, aerospace, electrical and most recently biomedical engineering. This book aims to present the advanced development of RP technologies in various engineering areas as the solutions to the real world engineering problems

    Computational Modeling of Fracture Failure in Mineralized and Prosthetic Biomaterials

    Get PDF
    Natural mineralized tissues, e.g., teeth and bone, have the capacity to tolerate the daily physiological loading. However, due to their high mineralized composition, they have been recognized as a class of relatively brittle biomaterials. The inherent brittle nature and fairly high susceptibility to mechanical failure present a more critical problem in biomedical research field. To replace such diseased or damaged mineralized tissues, prosthetic materials are largely applied in the areas of dental and osteo clinical treatments. Ceramic materials provide numerous favourable characteristics, including biocompatibility and chemical resistance. In addition to the dental industry, applications of osteofixation/osteosynthiesis devices are considered fundamental to stabilize various treatments of bone defects for promoting osteointegration and reconstruction. However, clinical observations and specialized literature have revealed that dental restorative materials and prosthetic fixation devices are often subject to high stress, leading to fracture either by catastrophic overloading or cyclic fatigue failure. The aim of this thesis is to develop a computational modelling framework on the basis of the extended finite element method (XFEM) to investigate the fracture behaviors of mineralised and synthetic biomaterials in various medical applications. The XFEM modelling results are validated by being compared with the in-vitro experiments and/or clinical observations. Through the research in this thesis studies, XFEM has been demonstrated to be a powerful tool to analyse fracture behaviors in the bio-structures subjected to not only static loadings but also cyclic loadings. The outcomes generated in this thesis help gain some insightful understanding failure of the native or prosthetic structures, which is anticipated to provide some clinical guidelines for the design optimisation of patient-specific prosthetic devices to ensure their reliability and longevity

    A review of image-based simulation applications in high-value manufacturing

    Get PDF
    Image-Based Simulation (IBSim) is the process by which a digital representation of a real geometry is generated from image data for the purpose of performing a simulation with greater accuracy than with idealised Computer Aided Design (CAD) based simulations. Whilst IBSim originates in the biomedical field, the wider adoption of imaging for non-destructive testing and evaluation (NDT/NDE) within the High-Value Manufacturing (HVM) sector has allowed wider use of IBSim in recent years. IBSim is invaluable in scenarios where there exists a non-negligible variation between the ‘as designed’ and ‘as manufactured’ state of parts. It has also been used for characterisation of geometries too complex to accurately draw with CAD. IBSim simulations are unique to the geometry being imaged, therefore it is possible to perform part-specific virtual testing within batches of manufactured parts. This novel review presents the applications of IBSim within HVM, whereby HVM is the value provided by a manufactured part (or conversely the potential cost should the part fail) rather than the actual cost of manufacturing the part itself. Examples include fibre and aggregate composite materials, additive manufacturing, foams, and interface bonding such as welding. This review is divided into the following sections: Material Characterisation; Characterisation of Manufacturing Techniques; Impact of Deviations from Idealised Design Geometry on Product Design and Performance; Customisation and Personalisation of Products; IBSim in Biomimicry. Finally, conclusions are drawn, and observations made on future trends based on the current state of the literature

    Impact of Ear Occlusion on In-Ear Sounds Generated by Intra-oral Behaviors

    Get PDF
    We conducted a case study with one volunteer and a recording setup to detect sounds induced by the actions: jaw clenching, tooth grinding, reading, eating, and drinking. The setup consisted of two in-ear microphones, where the left ear was semi-occluded with a commercially available earpiece and the right ear was occluded with a mouldable silicon ear piece. Investigations in the time and frequency domains demonstrated that for behaviors such as eating, tooth grinding, and reading, sounds could be recorded with both sensors. For jaw clenching, however, occluding the ear with a mouldable piece was necessary to enable its detection. This can be attributed to the fact that the mouldable ear piece sealed the ear canal and isolated it from the environment, resulting in a detectable change in pressure. In conclusion, our work suggests that detecting behaviors such as eating, grinding, reading with a semi-occluded ear is possible, whereas, behaviors such as clenching require the complete occlusion of the ear if the activity should be easily detectable. Nevertheless, the latter approach may limit real-world applicability because it hinders the hearing capabilities.</p

    Management of bone defects with Bio-oss

    Get PDF
    Introduction: The defects in the alveolar bone might appear as a result of congenital malformations, traumatic injuries, periodontal disease, surgical traumas, chronic periapical changes and tumors from benign or malignant origin. The aim of this study was to provide solid and healthy area with application of Bio-Oss in the defect. Materials and methods: Based on the clinical diagnosisestablished by previously taken history, clinical examination and radiographic images oral-surgery interventions was made. To realize the aim of this work, augmentative material was implicated in the bone defects made in the patients after removal of follicular cyst, chronic periapical lesion, and parodontopathia. During the first and seventh day of the interventions, the patients have been followed through from aspect of possible development of local and general complications after the oral-surgery intervention. After period of one, three and six mount control x-ray was made. Results: Obtained results confirmed that: volume of the socket and defect of the bone was kept, fast revascularization was achieved, bone formation and slow resorption of the augmentative material was achieved, and period of normal healing without infection was also achieved. Conclusions: The augmentative materials used for treatment of bone defects besides their basic chemical and physical characteristics referring to their solubility in the body fluids, the transformation, modulation and resorption must be completely safe or secure, i.e. not to bring any risk of infection, immunological risk, physiological intolerance or inhibition of the process of restitutio ad integrum. In our study Bio-Oss was confirmed as augmentative material who had this characteristics. Keywords: bone defect, resorption of the bone, augmentative material, Bio-Os
    corecore