761 research outputs found

    Rapid Wireless Capacitor Charging Using a Multi-Tapped Inductively-Coupled Secondary Coil

    Get PDF
    This paper presents an inductive coupling system designed to wirelessly charge ultra-capacitors used as energy storage elements. Although ultra-capacitors offer the native ability to rapidly charge, it is shown that standard inductive coupling circuits only deliver maximal power for a specific load impedance which depends on coil geometries and separation distances. Since a charging ultra-capacitor can be modeled as an increasing instantaneous impedance, maximum power is thus delivered to the ultra-capacitor at only a single point in the charging interval, resulting in a longer than optimal charging time. Analysis of inductive coupling theory reveals that the optimal load impedance can be modified by adjusting the secondary coil inductance and resonant tuning capacitance. A three-tap secondary coil is proposed to dynamically modify the optimal load impedance throughout the capacitor charging interval. Measurement results show that the proposed architecture can expand its operational range by up to 2.5 × and charge a 2.5 F ultra-capacitor to 5 V upwards of 3.7 × faster than a conventional architecture.Semiconductor Research Corporation. Interconnect Focus Cente

    WIRELESS POWER TRANSFER TO BIOMEDICAL IMPLANTS

    Get PDF
    Ph.DDOCTOR OF PHILOSOPH

    Doctor of Philosophy

    Get PDF
    dissertationMore than a century ago, in his labs in Colorado Springs and New York, Nikola Tesla started experimenting with wireless power transfer (WPT). His ideas were ahead of his time, but they fell into obscurity shortly after his death. Nowadays, WPT is no longer thought of as science fiction: neural prostheses, wearables, cellphones, and even electric vehicles can be powered through WPT. In its most common implementation, WPT leverages the magnetic coupling between resonant transmitter and receiver coils to exchange energy. Considerable work is devoted to the design and optimization of WPT antennas; efficiently transmitting the required amount of power can only be accomplished when the coil coupling is in the right range. In this work, we explore the use of spatial filters in WPT systems. Spatial filters are capable of controlling the harmonic content of an incident wave: subwavelength focal spots, perfect lensing, and diffractionless beams are some of their uses. In the first part of this dissertation, the focus is on the analysis and design of a compact negative permeability metamaterial slab. Compared to other works in the literature, this slab is an extremely small fraction of the wavelength, and works at a low operating frequency. Analysis and experimental validation demonstrate that the resulting metamaterial sample can be used in a 2-coil WPT system to achieve large range and efficiency enhancements. In the second part of this dissertation, the analysis and implementation of holographic screens is presented. A method to reduce the fabrication complexity of the desired holographic screen while maintaining the fidelity of the prescribed field distribution is presented. We demonstrate our method through the analysis, design, and experimental validation of a nondiffractive beam launcher with a Bessel field distribution. Finally, we utilize the analysis and methods presented in this work to design an antenna capable of prescribing a uniform field distribution. Because of this property, this WPT antenna is capable of transmitting near constant power with near constant efficiency to the target receiver load, without the need of an adaptive compensation system

    Wireless Power Transfer For Biomedical Applications

    Get PDF
    In this research wireless power transfer using near-field inductive coupling is studied and investigated. The focus is on delivering power to implantable biomedical devices. The objective of this research is to optimize the size and performance of the implanted wireless biomedical sensors by: (1) proposing a hybrid multiband communication system for implantable devices that combines wireless communication link and power transfer, and (2) optimizing the wireless power delivery system. Wireless data and power links are necessary for many implanted biomedical devices such as biosensors, neural recording and stimulation devices, and drug delivery and monitoring systems. The contributions from this research work are summarized as follows: 1. Development of a combination of inductive power transfer and antenna system. 2. Design and optimization of novel microstrip antenna that may resonate at different ultra-high frequency bands including 415 MHz, 905 MHz, and 1300MHz. These antennas may be used to transfer power through radiation or send/receive data. 3. Design of high-frequency coil (13.56 MHz) to transfer power and optimization of the parameters for best efficiency. 4. Study of the performance of the hybrid antenna/coil system at various depths inside a body tissue model. 5. Minimizing the coupling effect between the coil and the antenna through addressed by optimizing their dimensions. 6. Study of the effects of lateral and angular misalignment on a hybrid compact system consisting of coil and antenna, as well as design and optimize the coilâs geometry which can provide maximum power efficiency under misalignment conditions. 7. Address the effects of receiver bending of a hybrid power transfer and communication system on the communication link budget and the transmitted power. 8. Study the wireless power transfer safety and security systems

    Enhancing wireless power transfer efficiency for potential use in cardiovascular applications

    Get PDF
    Left Ventricular Assist Devices (LVAD) are being used to assist blood circulation in heart failure patients. The requirement to have a continuous energy supply is deteriorating the patients’ life quality since they need either to carry along two heavy battery packs or to attach a power cable. For this reason, a wireless power transmission (WPT) system is developed to power the LVAD. Within its effective charging region, the WPT system will offer an autonomous charging process which may lead to a smaller battery pack and cableless experience to the user. Previous WPT systems for cardiovascular applications are either compromised by poor transfer efficiency, short transmission distance or safety issues. To address these problems, an impedance matching WPT system is being designed. For increasing the overall transfer efficiency, both sides impedance matching technique and low loss matching networks are being worked on. In addition, efficiency specific design approach is being developed to reduce design complexity. As a result, the transfer efficiency and transmission distance of the impedance matched WPT have been increased by a factor of 7 and 6 times respectively. The conceptual idea for implementing such a system is also discussed in this thesis. Furthermore, safety measurements have been performed to ensure the system is safe to be used

    A Novel Power-Efficient Wireless Multi-channel Recording System for the Telemonitoring of Electroencephalography (EEG)

    Get PDF
    This research introduces the development of a novel EEG recording system that is modular, batteryless, and wireless (untethered) with the supporting theoretical foundation in wireless communications and related design elements and circuitry. Its modular construct overcomes the EEG scaling problem and makes it easier for reconfiguring the hardware design in terms of the number and placement of electrodes and type of standard EEG system contemplated for use. In this development, portability, lightweight, and applicability to other clinical applications that rely on EEG data are sought. Due to printer tolerance, the 3D printed cap consists of 61 electrode placements. This recording capacity can however extend from 21 (as in the international 10-20 systems) up to 61 EEG channels at sample rates ranging from 250 to 1000 Hz and the transfer of the raw EEG signal using a standard allocated frequency as a data carrier. The main objectives of this dissertation are to (1) eliminate the need for heavy mounted batteries, (2) overcome the requirement for bulky power systems, and (3) avoid the use of data cables to untether the EEG system from the subject for a more practical and less restrictive setting. Unpredictability and temporal variations of the EEG input make developing a battery-free and cable-free EEG reading device challenging. Professional high-quality and high-resolution analog front ends are required to capture non-stationary EEG signals at microvolt levels. The primary components of the proposed setup are the wireless power transmission unit, which consists of a power amplifier, highly efficient resonant-inductive link, rectification, regulation, and power management units, as well as the analog front end, which consists of an analog to digital converter, pre-amplification unit, filtering unit, host microprocessor, and the wireless communication unit. These must all be compatible with the rest of the system and must use the least amount of power possible while minimizing the presence of noise and the attenuation of the recorded signal A highly efficient resonant-inductive coupling link is developed to decrease power transmission dissipation. Magnetized materials were utilized to steer electromagnetic flux and decrease route and medium loss while transmitting the required energy with low dissipation. Signal pre-amplification is handled by the front-end active electrodes. Standard bio-amplifier design approaches are combined to accomplish this purpose, and a thorough investigation of the optimum ADC, microcontroller, and transceiver units has been carried out. We can minimize overall system weight and power consumption by employing battery-less and cable-free EEG readout system designs, consequently giving patients more comfort and freedom of movement. Similarly, the solutions are designed to match the performance of medical-grade equipment. The captured electrical impulses using the proposed setup can be stored for various uses, including classification, prediction, 3D source localization, and for monitoring and diagnosing different brain disorders. All the proposed designs and supporting mathematical derivations were validated through empirical and software-simulated experiments. Many of the proposed designs, including the 3D head cap, the wireless power transmission unit, and the pre-amplification unit, are already fabricated, and the schematic circuits and simulation results were based on Spice, Altium, and high-frequency structure simulator (HFSS) software. The fully integrated head cap to be fabricated would require embedding the active electrodes into the 3D headset and applying current technological advances to miniaturize some of the design elements developed in this dissertation

    Design of Inductive Power Transfer (IPT) for Low-Power Application

    Get PDF
    Inductive power transfer (IPT) is preferred for numerous applications nowadays, ranging from microwatt bio-engineering devices to high power battery charging system. IPT system is based on the basic concept of electromagnetics induction which able to transfer the power from a source of electrical to the load without using any type of physical interconnection. This paper present a low-cost designed and implementation of IPT system via magnetic resonant coupling. NI Multisim 14.0 software was used to simulate the circuit diagram and the hardware prototype was developed for testing

    Design and Implementation of a Wireless Charging-Based Cardiac Monitoring System Focused on Temperature Reduction and Robust Power Transfer Efficiency

    Get PDF
    Wireless power transfer systems are increasingly used as a means of charging implantable medical devices. However, the heat or thermal radiation from the wireless power transfer system can be harmful to biological tissue. In this research, we designed and implemented a wireless power transfer system-based implantable medical device with low thermal radiation, achieving 44.5% coil-to-coil efficiency. To suppress thermal radiation from the transmitting coil during charging, we minimized the ESR value of the transmitting coil. To increase power transfer efficiency, a ferrite film was applied on the receiving part. Based on analyses, we fabricated a cardiac monitoring system with dimensions of 17 x 24 x 8 mm(3) and implanted it in a rat. We confirmed that the temperature of the wireless charging device increased by only 2 degrees C during the 70 min charging, which makes it safe enough to use as an implantable medical device charging system.11Ysciescopu
    corecore