515 research outputs found

    PET Reconstruction With an Anatomical MRI Prior Using Parallel Level Sets.

    Get PDF
    The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) offers unique possibilities. In this paper we aim to exploit the high spatial resolution of MRI to enhance the reconstruction of simultaneously acquired PET data. We propose a new prior to incorporate structural side information into a maximum a posteriori reconstruction. The new prior combines the strengths of previously proposed priors for the same problem: it is very efficient in guiding the reconstruction at edges available from the side information and it reduces locally to edge-preserving total variation in the degenerate case when no structural information is available. In addition, this prior is segmentation-free, convex and no a priori assumptions are made on the correlation of edge directions of the PET and MRI images. We present results for a simulated brain phantom and for real data acquired by the Siemens Biograph mMR for a hardware phantom and a clinical scan. The results from simulations show that the new prior has a better trade-off between enhancing common anatomical boundaries and preserving unique features than several other priors. Moreover, it has a better mean absolute bias-to-mean standard deviation trade-off and yields reconstructions with superior relative l2-error and structural similarity index. These findings are underpinned by the real data results from a hardware phantom and a clinical patient confirming that the new prior is capable of promoting well-defined anatomical boundaries.This research was funded by the EPSRC (EP/K005278/1) and EP/H046410/1 and supported by the National Institute for Health Research University College London Hospitals Biomedical Research Centre. M.J.E was supported by an IMPACT studentship funded jointly by Siemens and the UCL Faculty of Engineering Sciences. K.T. and D.A. are partially supported by the EPSRC grant EP/M022587/1.This is the author accepted manuscript. The final version is available from IEEE via http://dx.doi.org/10.1109/TMI.2016.254960

    Image Restoration Using Functional and Anatomical Information Fusion with Application to SPECT-MRI Images

    Get PDF
    Image restoration is usually viewed as an ill-posed problem in image processing, since there is no unique solution associated with it. The quality of restored image closely depends on the constraints imposed of the characteristics of the solution. In this paper, we propose an original extension of the NAS-RIF restoration technique by using information fusion as prior information with application in SPECT medical imaging. That extension allows the restoration process to be constrained by efficiently incorporating, within the NAS-RIF method, a regularization term which stabilizes the inverse solution. Our restoration method is constrained by anatomical information extracted from a high resolution anatomical procedure such as magnetic resonance imaging (MRI). This structural anatomy-based regularization term uses the result of an unsupervised Markovian segmentation obtained after a preliminary registration step between the MRI and SPECT data volumes from each patient. This method was successfully tested on 30 pairs of brain MRI and SPECT acquisitions from different subjects and on Hoffman and Jaszczak SPECT phantoms. The experiments demonstrated that the method performs better, in terms of signal-to-noise ratio, than a classical supervised restoration approach using a Metz filter

    Non-uniform resolution and partial volume recovery in tomographic image reconstruction methods

    Get PDF
    Acquired data in tomographic imaging systems are subject to physical or detector based image degrading effects. These effects need to be considered and modeled in order to optimize resolution recovery. However, accurate modeling of the physics of data and acquisition processes still lead to an ill-posed reconstruction problem, because real data is incomplete and noisy. Real images are always a compromise between resolution and noise; therefore, noise processes also need to be fully considered for optimum bias variance trade off. Image degrading effects and noise are generally modeled in the reconstruction methods, while, statistical iterative methods can better model these effects, with noise processes, as compared to the analytical methods. Regularization is used to condition the problem and explicit regularization methods are considered better to model various noise processes with an extended control over the reconstructed image quality. Emission physics through object distribution properties are modeled in form of a prior function. Smoothing and edge-preserving priors have been investigated in detail and it has been shown that smoothing priors over-smooth images in high count areas and result in spatially non-uniform and nonlinear resolution response. Uniform resolution response is desirable for image comparison and other image processing tasks, such as segmentation and registration. This work proposes methods, based on MRPs in MAP estimators, to obtain images with almost uniform and linear resolution characteristics, using nonlinearity of MRPs as a correction tool. Results indicate that MRPs perform better in terms of response linearity, spatial uniformity and parameter sensitivity, as compared to QPs and TV priors. Hybrid priors, comprised of MRPs and QPs, have been developed and analyzed for their activity recovery performance in two popular PVC methods and for an analysis of list-mode data reconstruction methods showing that MPRs perform better than QPs in different situations

    Fast Predictions of Variance Images for Fan-Beam Transmission Tomography With Quadratic Regularization

    Full text link
    Accurate predictions of image variances can be useful for reconstruction algorithm analysis and for the design of regularization methods. Computing the predicted variance at every pixel using matrix-based approximations is impractical. Even most recently adopted methods that are based on local discrete Fourier approximations are impractical since they would require a forward and backprojection and two fast Fourier transform (FFT) calculations for every pixel, particularly for shift-variant systems like fan-beam tomography. This paper describes new "analytical" approaches to predicting the approximate variance maps of 2-D images that are reconstructed by penalized-likelihood estimation with quadratic regularization in fan-beam geometries. The simplest of the proposed analytical approaches requires computation equivalent to one backprojection and some summations, so it is computationally practical even for the data sizes in X-ray computed tomography (CT). Simulation results show that it gives accurate predictions of the variance maps. The parallel-beam geometry is a simple special case of the fan-beam analysis. The analysis is also applicable to 2-D positron emission tomography (PET).Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/86007/1/Fessler37.pd
    corecore