24,756 research outputs found

    Systemdienstleistungserbringung durch intelligente GebÀude

    Get PDF
    Within the ongoing transition of energy systems, new technologies are integrated into electrical distribution systems—e. g. distributed generation, electrical storage, electric vehicles and automated building energy management—which transform buildings into actively participating components inside the grid. This thesis analyses the influences of those intelligent buildings’ capabilities of optimizing their in-house energy flows on low-voltage grids and discusses the usability of those capabilities to provide system services. In order to minimize the limitations which arise for the economic acting on energy markets for the inhabitants of such buildings, the traffic light concept is shaped as an approach to provide necessary needed system services. Firstly, a technical traffic light is introduced to determine critical situations in the grid. Secondly, a topological traffic light identifies active components that can reasonably participate in the clearance of a critical situation. Thirdly, aspects of coordination by the traffic light are tackled by a closed-loop feedback mechanism that controls utility equipment and intelligent buildings by utilizing a two-staged mechanism for demand response. The three parts of the proposed traffic light approach are implemented in a Regional Energy Management System that utilizes a proposed Extended Generic Observer/Controller-Architecture. For a close-to-reality evaluation three reference grids for a rural, village, and suburban residential low voltage grid are derived from literature as well as three scenarios for the distribution of active components. In particular distributed generation, electrical storage and electric vehicles. The simulation of intelligent buildings, utility equipment, and the low voltage grid as well as the Regional Energy Management System are implemented in a Co-Simulation environment that extends the Organic Smart Home to a microgrid simulation. Furthermore, this simulation is extended towards a Software-in-a-Hardware-Loop-Environment comprising the Co-Simulation and the KIT Energy Smart Home Lab as a real intelligent building, to comply with the necessity of evaluating the Regional Energy Management System with real hardware. Here, a loose coupling of software and hardware components is established by using event-based communication schemes utilizing a message bus and an artificial mains is used to align the environmental conditions between simulation and real building. The capabilities of the Regional Energy Management System to stabilize low voltage systems, especially in future scenarios, are investigated in simulation studies and its operation is successfully demonstrated in the presented Software-in-a-Hardware-Loop-Environment during a six-day test phase in the real intelligent building

    ERIGrid Holistic Test Description for Validating Cyber-Physical Energy Systems

    Get PDF
    Smart energy solutions aim to modify and optimise the operation of existing energy infrastructure. Such cyber-physical technology must be mature before deployment to the actual infrastructure, and competitive solutions will have to be compliant to standards still under development. Achieving this technology readiness and harmonisation requires reproducible experiments and appropriately realistic testing environments. Such testbeds for multi-domain cyber-physical experiments are complex in and of themselves. This work addresses a method for the scoping and design of experiments where both testbed and solution each require detailed expertise. This empirical work first revisited present test description approaches, developed a newdescription method for cyber-physical energy systems testing, and matured it by means of user involvement. The new Holistic Test Description (HTD) method facilitates the conception, deconstruction and reproduction of complex experimental designs in the domains of cyber-physical energy systems. This work develops the background and motivation, offers a guideline and examples to the proposed approach, and summarises experience from three years of its application.This work received funding in the European Community’s Horizon 2020 Program (H2020/2014–2020) under project “ERIGrid” (Grant Agreement No. 654113)

    International White Book on DER Protection : Review and Testing Procedures

    Get PDF
    This white book provides an insight into the issues surrounding the impact of increasing levels of DER on the generator and network protection and the resulting necessary improvements in protection testing practices. Particular focus is placed on ever increasing inverter-interfaced DER installations and the challenges of utility network integration. This white book should also serve as a starting point for specifying DER protection testing requirements and procedures. A comprehensive review of international DER protection practices, standards and recommendations is presented. This is accompanied by the identiïŹ cation of the main performance challenges related to these protection schemes under varied network operational conditions and the nature of DER generator and interface technologies. Emphasis is placed on the importance of dynamic testing that can only be delivered through laboratory-based platforms such as real-time simulators, integrated substation automation infrastructure and ïŹ‚ exible, inverter-equipped testing microgrids. To this end, the combination of ïŹ‚ exible network operation and new DER technologies underlines the importance of utilising the laboratory testing facilities available within the DERlab Network of Excellence. This not only informs the shaping of new protection testing and network integration practices by end users but also enables the process of de-risking new DER protection technologies. In order to support the issues discussed in the white paper, a comparative case study between UK and German DER protection and scheme testing practices is presented. This also highlights the level of complexity associated with standardisation and approval mechanisms adopted by different countries

    Smart Power Grid Synchronization With Fault Tolerant Nonlinear Estimation

    Get PDF
    Effective real-time state estimation is essential for smart grid synchronization, as electricity demand continues to grow, and renewable energy resources increase their penetration into the grid. In order to provide a more reliable state estimation technique to address the problem of bad data in the PMU-based power synchronization, this paper presents a novel nonlinear estimation framework to dynamically track frequency, voltage magnitudes and phase angles. Instead of directly analyzing in abc coordinate frame, symmetrical component transformation is employed to separate the positive, negative, and zero sequence networks. Then, Clarke\u27s transformation is used to transform the sequence networks into the αÎČ stationary coordinate frame, which leads to system model formulation. A novel fault tolerant extended Kalman filter based real-time estimation framework is proposed for smart grid synchronization with noisy bad data measurements. Computer simulation studies have demonstrated that the proposed fault tolerant extended Kalman filter (FTEKF) provides more accurate voltage synchronization results than the extended Kalman filter (EKF). The proposed approach has been implemented with dSPACE DS1103 and National Instruments CompactRIO hardware platforms. Computer simulation and hardware instrumentation results have shown the potential applications of FTEKF in smart grid synchronization

    Realization of a 10 kW MES power to methane plant based on unified AC/DC converter

    Get PDF
    This paper presents a galvanic isolated multi output AC/DC topology that is suitable for Microbial electrosynthesis (MES) based Power to Methane energy storage systems. The presented scheme utilizes a three phase back to back converters, a single-input and multiple-output three phase transformer, single diode rectifiers and buck converters that employ a proper interconnection between MES cells and the mains. The proposed topology merges all the required single phase AC/DC converters as a unified converter which reduces the overall system size and provides system integrity and overall controllability. The proposed control scheme allows to achieve the following desired goals:1) Simultaneous control of all cells; 2) Absorbing power from the grid and covert to methane when the electricity price goes down; 3) the power factor and the quality of grid current is under control; 4) Supplying MES cells at the optimal operating point. For verification of system performance, Real time simulation results that are obtained from a 10-kW MES energy storage are presented.Postprint (author's final draft

    Ancillary service provision by demand side management : a real-time power hardware-in-the-loop co-simulation demonstration

    Get PDF
    The role of demand side management in providing ancillary services to the network is an active topic of research. However, their implementation is limited due to lack of practical demonstrations and tests that can rigorously quantify their ability to support the grid’s integrity. In this paper, provision of time critical frequency control ancillary service is demonstrated by means of integrating PowerMatcher, a well discussed demand side management mechanism in literature, with real-time power hardware. The co-simulation platform enables testing of demand side management techniques to provide ancillary services

    Measurement-based network clustering for active distribution systems

    Get PDF
    ©2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.This paper presents a network clustering (NC) method for active distribution networks (ADNs). Following the outage of a section of an ADN, the method identifies and forms an optimum cluster of microgrids within the section. The optimum cluster is determined from a set of candidate microgrid clusters by estimating the following metrics: total power loss, voltage deviations, and minimum load shedding. To compute these metrics, equivalent circuits of the clusters are estimated using measured data provided by phasor measurement units (PMUs). Hence, the proposed NC method determines the optimum microgrid cluster without requiring information about the network’s topology and its components. The proposed method is tested by simulating a study network in a real-time simulator coupled to physical PMUs and a prototype algorithm implementation, also executing in real time.Peer ReviewedPostprint (author's final draft
    • 

    corecore