41 research outputs found

    Textural Features in Medical Magnetic Resonance Image Analysis of the Brain and Thigh Muscles

    Get PDF
    Magnetic resonance imaging (MRI) provides high-quality images with excellent contrast detail of soft tissues and anatomic structures. MR images contain a large amount of detailed information – some of which is invisible to the human eye. Detailed information can be analysed with computer-assisted texture analysis (TA), which is based on features describing the grey level relationships between image pixels. The aim of this thesis was to assess the information content of textural features based on the image histogram, grey level co-occurrence matrix, and grey level run-length matrix. The strengths and limitations of the various textural features in medical MR image analysis were evaluated. The study was conducted by analysing different clinical data with TA in the clinical environment, and the results of the learning process were then gathered in this thesis. Our results indicated that all features have limitations in terms of their discrimination capacity in medical MR images and their dependence on the size of the region of interest and MR imaging parameters. By considering these limitations, TA may help in various MR imaging applications by revealing textural information of the images of various human organs. <br/

    MRI-based radiomics: Quantifying the stability and reproducibility of tumour heterogeneity in vivo and in a 3D printed phantom

    Full text link
    Magnetic resonance imaging (MRI) is a key component in the oncology workflow. Radiomics analysis is a new approach that uses standard of care (SOC) magnetic resonance (MR) images to non-invasively characterise tumour heterogeneity. For radiomics to be reliable, the imaging features measured must be stable and reproducible. This thesis aims to quantify the stability and reproducibility of MRI-based radiomics in vivo and in a 3D printed phantom. Chapter 4 explores the feasibility of constructing a 3D printed phantom using an MRI visible material (‘red resin’). The study shows that the material used to construct an anthropomorphic skull phantom mimicked human cortical bone with a T2* of 411 ± 19 µs. The phantom material provided sufficient signal for tissue segmentation however was only visible with an ultrashort echo time sequence, not commonly used in SOC imaging. Chapter 5 investigates a high temperature resin (‘white resin’) where a texture object was developed for analysis. The ‘white resin’ was visible using SOC sequences. The interscanner repeatability measurements of the texture phantom demonstrated high reproducibility with 76% of texture features having an ICC > 0.9. In chapter 6, further texture and shape objects were developed and employed in a multi-centre study assessing inter and intrascanner variation of MRI-based radiomics. The phantom was stable over a period of 12 months, with a T1 and T2 of 150.7 ± 6.7 ms and 56.1 ± 3.9 ms, respectively. The study also found that histogram features were more stable (ICC > 0.8 for 67%) compared to texture (ICC > 0.8 for 58%) and shape texture (ICC > 0.8 for 0%) across the 8 scanners. In chapter 7, phantom measurements found that radiomics features were more sensitive to changes of image resolution and noise. The in vivo test-retest component of chapter 7 detected many unstable features not suitable for use in a radiomics prognostic model. In chapter 8, of the 83 features computed only 19 features had significant changes between the baseline, mid and post radiation treatment and may be informative to assess rectal cancer treatment response. When considering using radiomics analysis for SOC MRI scans, caution must be taken to ensure imaging protocols, imaging equipment including scanners and coils are consistent to improve intra and inter-institutional feature robustness. This can be achieved with regular quality assurance (QA) of imaging protocols using a suitable phantom and appropriate feature selection using phantom and in vivo datasets

    Biomedical Image Processing and Classification

    Get PDF
    Biomedical image processing is an interdisciplinary field involving a variety of disciplines, e.g., electronics, computer science, physics, mathematics, physiology, and medicine. Several imaging techniques have been developed, providing many approaches to the study of the human body. Biomedical image processing is finding an increasing number of important applications in, for example, the study of the internal structure or function of an organ and the diagnosis or treatment of a disease. If associated with classification methods, it can support the development of computer-aided diagnosis (CAD) systems, which could help medical doctors in refining their clinical picture

    Doctor of Philosophy

    Get PDF
    dissertationCongenital heart defects are classes of birth defects that affect the structure and function of the heart. These defects are attributed to the abnormal or incomplete development of a fetal heart during the first few weeks following conception. The overall detection rate of congenital heart defects during routine prenatal examination is low. This is attributed to the insufficient number of trained personnel in many local health centers where many cases of congenital heart defects go undetected. This dissertation presents a system to identify congenital heart defects to improve pregnancy outcomes and increase their detection rates. The system was developed and its performance assessed in identifying the presence of ventricular defects (congenital heart defects that affect the size of the ventricles) using four-dimensional fetal chocardiographic images. The designed system consists of three components: 1) a fetal heart location estimation component, 2) a fetal heart chamber segmentation component, and 3) a detection component that detects congenital heart defects from the segmented chambers. The location estimation component is used to isolate a fetal heart in any four-dimensional fetal echocardiographic image. It uses a hybrid region of interest extraction method that is robust to speckle noise degradation inherent in all ultrasound images. The location estimation method's performance was analyzed on 130 four-dimensional fetal echocardiographic images by comparison with manually identified fetal heart region of interest. The location estimation method showed good agreement with the manually identified standard using four quantitative indexes: Jaccard index, Sørenson-Dice index, Sensitivity index and Specificity index. The average values of these indexes were measured at 80.70%, 89.19%, 91.04%, and 99.17%, respectively. The fetal heart chamber segmentation component uses velocity vector field estimates computed on frames contained in a four-dimensional image to identify the fetal heart chambers. The velocity vector fields are computed using a histogram-based optical flow technique which is formulated on local image characteristics to reduces the effect of speckle noise and nonuniform echogenicity on the velocity vector field estimates. Features based on the velocity vector field estimates, voxel brightness/intensity values, and voxel Cartesian coordinate positions were extracted and used with kernel k-means algorithm to identify the individual chambers. The segmentation method's performance was evaluated on 130 images from 31 patients by comparing the segmentation results with manually identified fetal heart chambers. Evaluation was based on the Sørenson-Dice index, the absolute volume difference and the Hausdorff distance, with each resulting in per patient average values of 69.92%, 22.08%, and 2.82 mm, respectively. The detection component uses the volumes of the identified fetal heart chambers to flag the possible occurrence of hypoplastic left heart syndrome, a type of congenital heart defect. An empirical volume threshold defined on the relative ratio of adjacent fetal heart chamber volumes obtained manually is used in the detection process. The performance of the detection procedure was assessed by comparison with a set of images with confirmed diagnosis of hypoplastic left heart syndrome and a control group of normal fetal hearts. Of the 130 images considered 18 of 20 (90%) fetal hearts were correctly detected as having hypoplastic left heart syndrome and 84 of 110 (76.36%) fetal hearts were correctly detected as normal in the control group. The results show that the detection system performs better than the overall detection rate for congenital heart defect which is reported to be between 30% and 60%

    On-line quality control in polymer processing using hyperspectral imaging

    Get PDF
    L’industrie du plastique se tourne de plus en plus vers les matériaux composites afin d’économiser de la matière et/ou d’utiliser des matières premières à moindres coûts, tout en conservant de bonnes propriétés. L’impressionnante adaptabilité des matériaux composites provient du fait que le manufacturier peut modifier le choix des matériaux utilisés, la proportion selon laquelle ils sont mélangés, ainsi que la méthode de mise en œuvre utilisée. La principale difficulté associée au développement de ces matériaux est l’hétérogénéité de composition ou de structure, qui entraîne généralement des défaillances mécaniques. La qualité des prototypes est normalement mesurée en laboratoire, à partir de tests destructifs et de méthodes nécessitant la préparation des échantillons. La mesure en-ligne de la qualité permettrait une rétroaction quasi-immédiate sur les conditions d’opération des équipements, en plus d’être directement utilisable pour le contrôle de la qualité dans une situation de production industrielle. L’objectif de la recherche proposée consiste à développer un outil de contrôle de qualité pour la qualité des matériaux plastiques de tout genre. Quelques sondes de type proche infrarouge ou ultrasons existent présentement pour la mesure de la composition en-ligne, mais celles-ci ne fournissent qu’une valeur ponctuelle à chaque acquisition. Ce type de méthode est donc mal adapté pour identifier la distribution des caractéristiques de surface de la pièce (i.e. homogénéité, orientation, dispersion). Afin d’atteindre cet objectif, un système d’imagerie hyperspectrale est proposé. À l’aide de cet appareil, il est possible de balayer la surface de la pièce et d’obtenir une image hyperspectrale, c’est-à-dire une image formée de l’intensité lumineuse à des centaines de longueurs d’onde et ce, pour chaque pixel de l’image. L’application de méthodes chimiométriques permettent ensuite d’extraire les caractéristiques spatiales et spectrales de l’échantillon présentes dans ces images. Finalement, les méthodes de régression multivariée permettent d’établir un modèle liant les caractéristiques identifiées aux propriétés de la pièce. La construction d’un modèle mathématique forme donc l’outil d’analyse en-ligne de la qualité des pièces qui peut également prédire et optimiser les conditions de fabrication.The use of plastic composite materials has been increasing in recent years in order to reduce the amount of material used and/or use more economic materials, all of which without compromising the properties. The impressive adaptability of these composite materials comes from the fact that the manufacturer can choose the raw materials, the proportion in which they are blended as well as the processing conditions. However, these materials tend to suffer from heterogeneous compositions and structures, which lead to mechanical weaknesses. Product quality is generally measured in the laboratory, using destructive tests often requiring extensive sample preparation. On-line quality control would allow near-immediate feedback on the operating conditions and may be transferrable to an industrial production context. The proposed research consists of developing an on-line quality control tool adaptable to plastic materials of all types. A number of infrared and ultrasound probes presently exist for on-line composition estimation, but only provide single-point values at each acquisition. These methods are therefore less adapted for identifying the spatial distribution of a sample’s surface characteristics (e.g. homogeneity, orientation, dispersion). In order to achieve this objective, a hyperspectral imaging system is proposed. Using this tool, it is possible to scan the surface of a sample and obtain a hyperspectral image, that is to say an image in which each pixel captures the light intensity at hundreds of wavelengths. Chemometrics methods can then be applied to this image in order to extract the relevant spatial and spectral features. Finally, multivariate regression methods are used to build a model between these features and the properties of the sample. This mathematical model forms the backbone of an on-line quality assessment tool used to predict and optimize the operating conditions under which the samples are processed

    Transform- and statistical-based image analysis for assessment of deterioration in concrete infrastructure

    Get PDF
    The evaluation of the condition of infrastructure requires the development and optimization of alternative inspection methods for assessing surface deterioration in order to obtain accurate and quantitative information to supplement visual inspections. To this end, non-destructive methods that produce image data show great potential and are increasingly being used in concrete applications. These methods, based on IR thermography and greyscale and colour imaging, are generally cost and time effective and are relatively easy to employ. There is, however, a need for efficient image analysis techniques to extract relevant damage information from the imagery. In this context, this research proposes the use of grey level co-occurrence matrix statistical texture analysis in combination with Haar's wavelet analysis for improved defect detection. Two classifiers are proposed, the supervised multi-layer perceptron artificial neural network and the unsupervised K -means clustering approach, for evaluation of their effectiveness in characterizing the deterioration from the imagery. These techniques are applied to thermographic, colour and greyscale imagery of laboratory specimens and field samples exhibiting different levels of concrete deterioration. Further experiments are conducted on borehole acoustic imagery involving the additional techniques of spatial filters and edge-detectors in an effort to determine their efficiency in detecting concrete damage.The results demonstrate that the hybrid texture approach is quite effective for defect discrimination. They also indicate that the lowpass and median spatial filters performed better than the gradient-based and Laplacian edge-detectors; however, the texture approaches outperformed all of the other techniques.The artificial neural network was found to provide better classification accuracies compared with the K -means algorithm. Concerning the imagery, the thermography produced more accurate results than the colour and greyscale imagery.The information derived from the imagery consists of total surface damage; for map-crack imagery, the total length of cracks and range of crack width openings were also computed.The damage quantities obtained for the laboratory specimens show good correlation with test measurements recorded for the specimens, such as expansion and impact-echo velocities

    Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates

    Get PDF
    The study of cerebral anatomy in developing neonates is of great importance for the understanding of brain development during the early period of life. This dissertation therefore focuses on three challenges in the modelling of cerebral anatomy in neonates during brain development. The methods that have been developed all use Magnetic Resonance Images (MRI) as source data. To facilitate study of vascular development in the neonatal period, a set of image analysis algorithms are developed to automatically extract and model cerebral vessel trees. The whole process consists of cerebral vessel tracking from automatically placed seed points, vessel tree generation, and vasculature registration and matching. These algorithms have been tested on clinical Time-of- Flight (TOF) MR angiographic datasets. To facilitate study of the neonatal cortex a complete cerebral cortex segmentation and reconstruction pipeline has been developed. Segmentation of the neonatal cortex is not effectively done by existing algorithms designed for the adult brain because the contrast between grey and white matter is reversed. This causes pixels containing tissue mixtures to be incorrectly labelled by conventional methods. The neonatal cortical segmentation method that has been developed is based on a novel expectation-maximization (EM) method with explicit correction for mislabelled partial volume voxels. Based on the resulting cortical segmentation, an implicit surface evolution technique is adopted for the reconstruction of the cortex in neonates. The performance of the method is investigated by performing a detailed landmark study. To facilitate study of cortical development, a cortical surface registration algorithm for aligning the cortical surface is developed. The method first inflates extracted cortical surfaces and then performs a non-rigid surface registration using free-form deformations (FFDs) to remove residual alignment. Validation experiments using data labelled by an expert observer demonstrate that the method can capture local changes and follow the growth of specific sulcus

    Non-invasive ultrasound monitoring of regional carotid wall structure and deformation in atherosclerosis

    Get PDF
    Thesis (Ph. D.)--Harvard--Massachusetts Institute of Technology Division of Health Sciences and Technology, 2001.Includes bibliographical references (p. 223-242).Atherosclerosis is characterized by local remodeling of arterial structure and distensibility. Developing lesions either progress gradually to compromise tissue perfusion or rupture suddenly to cause catastrophic myocardial infarction or stroke. Reliable measurement of changes in arterial structure and composition is required for assessment of disease progression. Non-invasive carotid ultrasound can image the heterogeneity of wall structure and distensibility caused by atherosclerosis. However, this capability has not been utilized for clinical monitoring because of speckle noise and other artifacts. Clinical measures focus instead on average wall thickness and diameter distension in the distal common carotid to reduce sensitivity to noise. The goal of our research was to develop an effective system for reliable regional structure and deformation measurements since these are more sensitive indicators of disease progression. We constructed a system for freehand ultrasound scanning based on custom software which simultaneously acquires real-time image sequences and 3D frame localization data from an electromagnetic spatial localizer. With finite element modeling, we evaluated candidate measures of regional wall deformation.(cont.) Finally, we developed a multi-step scheme for robust estimation of local wall structure and deformation. This new strategy is based on a directionally-sensitive segmentation functional and a motion-region-of-interest constrained optical flow algorithm. We validated this estimator with simulated images and clinical ultrasound data. The results show structure estimates that are accurate and precise, with inter- and intra-observer reproducibility surpassing existing methods. Estimates of wall velocity and deformation likewise show good overall accuracy and precision. We present results from a proof-of-principle evaluation conducted in a pilot study of normal subjects and clinical patients. For one example, we demonstrate the combination of 2D image processing with 3D frame localization for visualization of the carotid volume. With slice localization, estimates of carotid wall structure and deformation can be derived for all axial positions along the carotid artery. The elements developed here provide the tools necessary for reliable quantification of regional wall structure and composition changes which result from atherosclerosis.by Raymond C. Chan.Ph.D

    Foetal echocardiographic segmentation

    Get PDF
    Congenital heart disease affects just under one percentage of all live births [1]. Those defects that manifest themselves as changes to the cardiac chamber volumes are the motivation for the research presented in this thesis. Blood volume measurements in vivo require delineation of the cardiac chambers and manual tracing of foetal cardiac chambers is very time consuming and operator dependent. This thesis presents a multi region based level set snake deformable model applied in both 2D and 3D which can automatically adapt to some extent towards ultrasound noise such as attenuation, speckle and partial occlusion artefacts. The algorithm presented is named Mumford Shah Sarti Collision Detection (MSSCD). The level set methods presented in this thesis have an optional shape prior term for constraining the segmentation by a template registered to the image in the presence of shadowing and heavy noise. When applied to real data in the absence of the template the MSSCD algorithm is initialised from seed primitives placed at the centre of each cardiac chamber. The voxel statistics inside the chamber is determined before evolution. The MSSCD stops at open boundaries between two chambers as the two approaching level set fronts meet. This has significance when determining volumes for all cardiac compartments since cardiac indices assume that each chamber is treated in isolation. Comparison of the segmentation results from the implemented snakes including a previous level set method in the foetal cardiac literature show that in both 2D and 3D on both real and synthetic data, the MSSCD formulation is better suited to these types of data. All the algorithms tested in this thesis are within 2mm error to manually traced segmentation of the foetal cardiac datasets. This corresponds to less than 10% of the length of a foetal heart. In addition to comparison with manual tracings all the amorphous deformable model segmentations in this thesis are validated using a physical phantom. The volume estimation of the phantom by the MSSCD segmentation is to within 13% of the physically determined volume
    corecore