1,326 research outputs found
A robotic microsurgical forceps for transoral laser microsurgery
Purpose:
In transoral laser microsurgery (TLM), the close curved cylindrical structure of the laryngeal region offers functional challenges to surgeons who operate on its malignancies with rigid, single degree-of-freedom (DOF) forceps. These challenges include surgeon hand tremors, poor reachability, poor tissue surface perception, and reduced ergonomy in design. The integrated robotic microsurgical forceps presented here is capable of addressing the above challenges through tele-operated tissue manipulation in TLM.
Methods:
The proposed device is designed in compliance with the spatial constraints in TLM. It incorporates a novel 2-DOF motorized microsurgical forceps end-effector, which is integrated with a commercial 6-DOF serial robotic manipulator. The integrated device is tele-operated through the haptic master interface, Omega.7. The device is augmented with a force sensor to measure tissue gripping force. The device is called RMF-2F, i.e. robotic microsurgical forceps with 2-DOF end-effector and force sensing. RMF-2F is evaluated through validation trials and pick-n-place experiments with subjects. Furthermore, the device is trialled with expert surgeons through preliminary tasks in a simulated surgical scenario.
Results:
RMF-2F shows a motion tracking error of less than 400 μm. User trials demonstrate the device’s accuracy in task completion and ease of manoeuvrability using the Omega.7 through improved trajectory following and execution times. The tissue gripping force shows better regulation with haptic feedback (1.624 N) than without haptic feedback (2.116 N). Surgeons positively evaluated the device with appreciation for improved access in the larynx and gripping force feedback.
Conclusions:
RMF-2F offers an ergonomic and intuitive interface for intraoperative tissue manipulation in TLM. The device performance, usability, and haptic feedback capability were positively evaluated by users as well as expert surgeons. RMF-2F introduces the benefits of robotic teleoperation including, (i) overcoming hand tremors and wrist excursions, (ii) improved reachability and accuracy, and (iii) tissue gripping feedback for safe tissue manipulation
Evaluation of Haptic Patterns on a Steering Wheel
Infotainment Systems can increase mental workload and divert
visual attention away from looking ahead on the roads.
When these systems give information to the driver, provide
it through the tactile channel on the steering, it wheel might
improve driving behaviour and safety. This paper describes an
investigation into the perceivability of haptic feedback patterns
using an actuated surface on a steering wheel. Six solenoids
were embedded along the rim of the steering wheel creating
three bumps under each palm. Maximally, four of the six
solenoids were actuated simultaneously, resulting in 56 patterns
to test. Participants were asked to keep in the middle
road of the driving simulator as good as possible. Overall
recognition accuracy of the haptic patterns was 81.3%, where
identification rate increased with decreasing number of active
solenoids (up to 92.2% for a single solenoid). There was no
significant increase in lane deviation or steering angle during
haptic pattern presentation. These results suggest that drivers
can reliably distinguish between cutaneous patterns presented
on the steering wheel. Our findings can assist in delivering
non-critical messages to the driver (e.g. driving performance,
incoming text messages, etc.) without decreasing driving performance
or increasing perceived mental workload
A Cost-Effective Haptic Device for Assistive and Rehabilitation Purposes
With the growing population of elderly, the need for assistance has also increased considerably especially for the tasks such as cleaning, reaching and grasping objects among others. There are numerous assistive devices in the market for this group of people. However, they are either too expensive or require overwhelming user effort for manipulation. Therefore, the presented research is primarily concerned with developing a low-cost, easy to use assistive device for elderly to reach and grasp objects through intuitive interface for the control of a slave anthropomorphic robotic arm (tele operator). The system also implements haptic feedback technology that enables the user to maneuver the grasping task in a realistic manner. A bilateral master-slave robotic system combined with the haptic feedback technology has been designed, built and tested to determine the suitability of this device for the chosen application. The final prototype consists of primarily off the shelf components programmed in such a way as to provide accurate teleoperation and haptic feedback to the user. While the nature of the project as a prototype precluded any patient trials, testing of the final system has shown that a fairly low cost device can be capable of providing the user an ability to remotely control a robotic arm for reaching and grasping objects with accurate force feedback
Design of a haptic device for teleoperation and virtual reality systems
IEEE International Conference on Systems, Man and Cybernetics, SMC 2009; San Antonio, TX; United States; 11 October 2009 through 14 October 2009Haptics technology has increased the precision and telepresence of the teleoperation and precision of the in-house robotic applications by force and surface information feedback. Force feedback is achieved through sending back the pressure and force information via a haptic device as the information is created or measured at the point of interest. In order to configure such a system, design, analysis and production processes of a haptic device, which is suitable for that specific application, becomes important. Today, haptic devices find use in assistive surgical robotics and most of the teleoperation systems. These devices are also extensively utilized in simulators to train medical and military personnel. The objective of this work is to design a haptic device with a new structure that has the potential to increase the precision of the robotic operation. Thus, literature is reviewed and possible robot manipulator designs are investigated to increase the precision in haptics applications. As a result of the investigations, conceptual designs are developed. Ultimately, final design is selected and produced after it is investigated in computer-aided- design (CAD) environment and its kinematic and structural analyses are carried out
Recommended from our members
fMRI-compatible rehabilitation hand device
BACKGROUND: Functional magnetic resonance imaging (fMRI) has been widely used in studying human brain functions and neurorehabilitation. In order to develop complex and well-controlled fMRI paradigms, interfaces that can precisely control and measure output force and kinematics of the movements in human subjects are needed. Optimized state-of-the-art fMRI methods, combined with magnetic resonance (MR) compatible robotic devices for rehabilitation, can assist therapists to quantify, monitor, and improve physical rehabilitation. To achieve this goal, robotic or mechatronic devices with actuators and sensors need to be introduced into an MR environment. The common standard mechanical parts can not be used in MR environment and MR compatibility has been a tough hurdle for device developers. METHODS: This paper presents the design, fabrication and preliminary testing of a novel, one degree of freedom, MR compatible, computer controlled, variable resistance hand device that may be used in brain MR imaging during hand grip rehabilitation. We named the device MR_CHIROD (Magnetic Resonance Compatible Smart Hand Interfaced Rehabilitation Device). A novel feature of the device is the use of Electro-Rheological Fluids (ERFs) to achieve tunable and controllable resistive force generation. ERFs are fluids that experience dramatic changes in rheological properties, such as viscosity or yield stress, in the presence of an electric field. The device consists of four major subsystems: a) an ERF based resistive element; b) a gearbox; c) two handles and d) two sensors, one optical encoder and one force sensor, to measure the patient induced motion and force. The smart hand device is designed to resist up to 50% of the maximum level of gripping force of a human hand and be controlled in real time. RESULTS: Laboratory tests of the device indicate that it was able to meet its design objective to resist up to approximately 50% of the maximum handgrip force. The detailed compatibility tests demonstrated that there is neither an effect from the MR environment on the ERF properties and performance of the sensors, nor significant degradation on MR images by the introduction of the MR_CHIROD in the MR scanner. CONCLUSION: The MR compatible hand device was built to aid in the study of brain function during generation of controllable and tunable force during handgrip exercising. The device was shown to be MR compatible. To the best of our knowledge, this is the first system that utilizes ERF in MR environment
Test bed experiments for various telerobotic system characteristics and configurations
Dexterous manipulation and grasping in telerobotic systems depends on the integration of high-performance sensors, displays, actuators and controls into systems in which careful consideration has been given to human perception and tolerance. Research underway at the Wisconsin Center for Space Automation and Robotics (WCSAR) has the objective of enhancing the performance of these systems and their components, and quantifying the effects of the many electrical, mechanical, control, and human factors that affect their performance. This will lead to a fundamental understanding of performance issues which will in turn allow designers to evaluate sensor, actuator, display, and control technologies with respect to generic measures of dexterous performance. As part of this effort, an experimental test bed was developed which has telerobotic components with exceptionally high fidelity in master/slave operation. A Telerobotic Performance Analysis System has also been developed which allows performance to be determined for various system configurations and electro-mechanical characteristics. Both this performance analysis system and test bed experiments are described
Upper Limb Terminal Device with Force and Position Feedback
ME450 Capstone Design and Manufacturing Experience: Winter 2010Current myoelectric prostheses lack the ability to provide sensory feedback, forcing amputees to rely solely on visual feedback. We have developed a prosthetic terminal device capable of relaying grip force back to the touch (haptic) receptors on the amputee’s residual limb. Our device is elemental to an experimental apparatus to test hypotheses in the value of haptic feedback. Our terminal device interfaces with the amputee’s residual limb and will be activated by electromyographic (EMG) signals. The prototype will be used in experimentation to test an amputee’s ability to distinguish object stiffness using haptic cues, in the absence of visual and auditory cues.http://deepblue.lib.umich.edu/bitstream/2027.42/109375/1/me450w10project18_report.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/109375/2/me450w10project18_photo.jp
- …