    Myoelectric forearm prostheses: State of the art from a user-centered perspective

    Get PDF
    User acceptance of myoelectric forearm prostheses is currently low. Awkward control, lack of feedback, and difficult training are cited as primary reasons. Recently, researchers have focused on exploiting the new possibilities offered by advancements in prosthetic technology. Alternatively, researchers could focus on prosthesis acceptance by developing functional requirements based on activities users are likely to perform. In this article, we describe the process of determining such requirements and then the application of these requirements to evaluating the state of the art in myoelectric forearm prosthesis research. As part of a needs assessment, a workshop was organized involving clinicians (representing end users), academics, and engineers. The resulting needs included an increased number of functions, lower reaction and execution times, and intuitiveness of both control and feedback systems. Reviewing the state of the art of research in the main prosthetic subsystems (electromyographic [EMG] sensing, control, and feedback) showed that modern research prototypes only partly fulfill the requirements. We found that focus should be on validating EMG-sensing results with patients, improving simultaneous control of wrist movements and grasps, deriving optimal parameters for force and position feedback, and taking into account the psychophysical aspects of feedback, such as intensity perception and spatial acuity

    Towards Bidirectional Lower Limb Prostheses: Restoring Proprioception Using EMG Based Vibrotactile Feedback

    Get PDF
    As a result, they do not effectively replace the lost limb. Electromyography (EMG) control has been widely implemented in upper limb prostheses but is still underdeveloped in lower limb prostheses. The aim of this thesis is to design, develop, and evaluate a novel vibrotactile feedback system in combination with an EMG-controlled powered knee or ankle prosthesis to restore proprioception. This thesis demonstrates that discrete localised vibrations enable proprioceptive sensing for the user through the described sensory feedback system. Three subjects with a major lower limb amputation performed level ground and inclined walking tests under various conditions. The experiments reported in the thesis compare the effects of EMG control with and without sensory feedback on temporal gait symmetry and psychosocial metrics, i.e. cognitive workload assessment, prosthesis embodiment, and confidence. The key results from this thesis are the following: temporal gait symmetry and psychosocial measures tended to improve within and between session, though the results varied widely between subjects. Interference in the rest EMG signal was found when the vibrotactors were activated. Further, subjects were able to distinguish between sensory feedback levels. EMG control initially reduced gait symmetry, but gait symmetry was later increased with sensory feedback. Higher symmetry scores were measured after sensory feedback was turned off, demonstrating learning retention. Similar trends were measured in psychosocial metrics, indicating that the sensory feedback system contributed to perceived improvements of the prosthesis. In summary, results show promising effects of using vibrotactile feedback in combination with EMG control in lower limb prostheses, despite the need to improve system robustness. Longer training with EMG and sensory feedback might improve quality of life of prosthesis users even more

    An exploration of grip force regulation with a low-impedance myoelectric prosthesis featuring referred haptic feedback

    Get PDF
    Abstract Background Haptic display technologies are well suited to relay proprioceptive, force, and contact cues from a prosthetic terminal device back to the residual limb and thereby reduce reliance on visual feedback. The ease with which an amputee interprets these haptic cues, however, likely depends on whether their dynamic signal behavior corresponds to expected behaviors—behaviors consonant with a natural limb coupled to the environment. A highly geared motor in a terminal device along with the associated high back-drive impedance influences dynamic interactions with the environment, creating effects not encountered with a natural limb. Here we explore grasp and lift performance with a backdrivable (low backdrive impedance) terminal device placed under proportional myoelectric position control that features referred haptic feedback. Methods We fabricated a back-drivable terminal device that could be used by amputees and non-amputees alike and drove aperture (or grip force, when a stiff object was in its grasp) in proportion to a myoelectric signal drawn from a single muscle site in the forearm. In randomly ordered trials, we assessed the performance of N=10 participants (7 non-amputee, 3 amputee) attempting to grasp and lift an object using the terminal device under three feedback conditions (no feedback, vibrotactile feedback, and joint torque feedback), and two object weights that were indiscernible by vision. Results Both non-amputee and amputee participants scaled their grip force according to the object weight. Our results showed only minor differences in grip force, grip/load force coordination, and slip as a function of sensory feedback condition, though the grip force at the point of lift-off for the heavier object was significantly greater for amputee participants in the presence of joint torque feedback. An examination of grip/load force phase plots revealed that our amputee participants used larger safety margins and demonstrated less coordination than our non-amputee participants. Conclusions Our results suggest that a backdrivable terminal device may hold advantages over non-backdrivable devices by allowing grip/load force coordination consistent with behaviors observed in the natural limb. Likewise, the inconclusive effect of referred haptic feedback on grasp and lift performance suggests the need for additional testing that includes adequate training for participants.http://deepblue.lib.umich.edu/bitstream/2027.42/116041/1/12984_2015_Article_98.pd

    Human-centered Electric Prosthetic (HELP) Hand

    Get PDF
    In developing countries such as India, there is a higher rate of amputations among the population but a lack of viable, low cost solutions. Through a partnership with Indian non-profit Bhagwan Mahaveer Viklang Sahayata Samiti (BMVSS), the team designed a functional, robust, and low cost electrically powered prosthetic hand that communicates with people with unilateral, transradial amputations in urban India through a biointerface. The device uses compliant tendon actuation, small linear servos, and a wearable sleeve outfitted with electromyography (EMG) sensors to produce a device that, once placed inside a prosthetic glove, is anthropomorphic in both look and feel. The hand is capable of forming three grips through the use of a manually adjustable opposable thumb: the key, pinch, and wrap grips. The hand also provides vibrotactile user feedback upon completion of a grip. The design includes a prosthetic gel liner to provide a layer of cushion and comfort for safe use by the user. These results show that it is possible to create a low cost, electrically powered prosthetic hand for users in developing countries without sacrificing functionality. In order for this design to be truly adjustable to each user, the creation of an easily navigable graphical user interface (GUI) will have to be a future goal. The prosthesis prototype was developed such that future groups can design for manufacturing and distribution in India

    Hap-Pro: a wearable haptic device for proprioceptive feedback

    Get PDF
    Objective: Myolectric hand prostheses have reached a considerable technological level and gained an increasing attention in assistive robotics. However, their abandonment rate remains high, with unintuitive control and lack of sensory feedback being major causes. Among the different types of sensory information, proprioception, e.g. information on hand aperture, is crucial to successfully perform everyday actions. Despite the many attempts in literature to restore and convey this type of feedback, much remains to be done to close the action-perception loop in prosthetic devices. Methods: With this as motivation, in this work we introduce HapPro, a wearable, non-invasive haptic device that can convey proprioceptive information for a prosthetic hand. The device was used with an under-actuated, simple to control anthropomorphic robotic hand, providing information on the level of hand aperture by mapping it to the position of a wheel that can run on the user's forearm. Tests with 43 able bodied subjects and one amputee subject were conducted in order to quantify the effectiveness of HapPro as a feedback device. Results: HapPro provided a good level of accuracy for item discrimination. Participants also reported the device to be intuitive and effective in conveying proprioceptive cues. Similar results were obtained in the proof-of-concept experiment with an amputee subject. Conclusions: Results show that HapPro is able to convey information on the opening of a prosthetic hand in a non-invasive way. Significance: Using this device for proprioceptive feedback could improve usability of myoelectric prostheses, potentially reducing abandonment and increasing quality of life for their users

    Human-centered Electric Prosthetic (HELP) Hand

    Get PDF
    Through a partnership with Indian non-profit Bhagwan Mahaveer Viklang Sahayata Samiti, we designed a functional, robust, and and low cost electrically powered prosthetic hand that communicates with unilateral, transradial, urban Indian amputees through a biointerface. The device uses compliant tendon actuation, a small linear servo, and a wearable garment outfitted with flex sensors to produce a device that, once placed inside a prosthetic glove, is anthropomorphic in both look and feel. The prosthesis was developed such that future groups can design for manufacturing and distribution in India

    Study and development of sensorimotor interfaces for robotic human augmentation

    Get PDF
    This thesis presents my research contribution to robotics and haptics in the context of human augmentation. In particular, in this document, we are interested in bodily or sensorimotor augmentation, thus the augmentation of humans by supernumerary robotic limbs (SRL). The field of sensorimotor augmentation is new in robotics and thanks to the combination with neuroscience, great leaps forward have already been made in the past 10 years. All of the research work I produced during my Ph.D. focused on the development and study of fundamental technology for human augmentation by robotics: the sensorimotor interface. This new concept is born to indicate a wearable device which has two main purposes, the first is to extract the input generated by the movement of the user's body, and the second to provide the somatosensory system of the user with an haptic feedback. This thesis starts with an exploratory study of integration between robotic and haptic devices, intending to combine state-of-the-art devices. This allowed us to realize that we still need to understand how to improve the interface that will allow us to feel the agency when using an augmentative robot. At this point, the path of this thesis forks into two alternative ways that have been adopted to improve the interaction between the human and the robot. In this regard, the first path we presented tackles two aspects conerning the haptic feedback of sensorimotor interfaces, which are the choice of the positioning and the effectiveness of the discrete haptic feedback. In the second way we attempted to lighten a supernumerary finger, focusing on the agility of use and the lightness of the device. One of the main findings of this thesis is that haptic feedback is considered to be helpful by stroke patients, but this does not mitigate the fact that the cumbersomeness of the devices is a deterrent to their use. Preliminary results here presented show that both the path we chose to improve sensorimotor augmentation worked: the presence of the haptic feedback improves the performance of sensorimotor interfaces, the co-positioning of haptic feedback and the input taken from the human body can improve the effectiveness of these interfaces, and creating a lightweight version of a SRL is a viable solution for recovering the grasping function

    A Review of Non-Invasive Haptic Feedback stimulation Techniques for Upper Extremity Prostheses

    Get PDF
    A sense of touch is essential for amputees to reintegrate into their social and work life. The design of the next generation of the prostheses will have the ability to effectively convey the tactile information between the amputee and the artificial limbs. This work reviews non-invasive haptic feedback stimulation techniques to convey the tactile information from the prosthetic hand to the amputee’s brain. Various types of actuators that been used to stimulate the patient’s residual limb for different types of artificial prostheses in previous studies have been reviewed in terms of functionality, effectiveness, wearability and comfort. The non-invasive hybrid feedback stimulation system was found to be better in terms of the stimulus identification rate of the haptic prostheses’ users. It can be conclude that integrating hybrid haptic feedback stimulation system with the upper limb prostheses leads to improving its acceptance among users

    Combined spatial and frequency encoding for electrotactile feedback of myoelectric signals

    Get PDF
    Electrotactile stimulation has been commonly used in human–machine interfaces to provide feedback to the user, thereby closing the control loop and improving performance. The encoding approach, which defines the mapping of the feedback information into stimulation profiles, is a critical component of an electrotactile interface. Ideally, the encoding will provide a high-fidelity representation of the feedback variable while being easy to perceive and interpret by the subject. In the present study, we performed a closed-loop experiment wherein discrete and continuous coding schemes are combined to exploit the benefits of both techniques. Subjects performed a muscle activation-matching task relying solely on electrotactile feedback representing the generated myoelectric signal (EMG). In particular, we investigated the performance of two different coding schemes (spatial and spatial combined with frequency) at two feedback resolutions (low: 3 and high: 5 intervals). In both schemes, the stimulation electrodes were placed circumferentially around the upper arm. The magnitude of the normalized EMG was divided into intervals, and each electrode was associated with one interval. When the generated EMG entered one of the intervals, the associated electrode started stimulating. In the combined encoding, the additional frequency modulation of the active electrode also indicated the momentary magnitude of the signal within the interval. The results showed that combined coding decreased the undershooting rate, variability and absolute deviation when the resolution was low but not when the resolution was high, where it actually worsened the performance. This demonstrates that combined coding can improve the effectiveness of EMG feedback, but that this effect is limited by the intrinsic variability of myoelectric control. Our findings, therefore, provide important insights as well as elucidate limitations of the information encoding methods when using electrotactile stimulation to convey a feedback signal characterized by high variability (EMG biofeedback)