3,134 research outputs found

    Voltage-Modulated Direct Power Control for a Weak Grid-Connected Voltage Source Inverters

    Get PDF

    Direct usage of photovoltaic solar panels to supply a freezer motor with variable DC input voltage

    Get PDF
    In this paper, a single-phase photovoltaic (PV) inverter fed by a boost converter to supply a freezer motor with variable DC input is investigated. The proposed circuit has two stages. Firstly, the DC output of the PV panel that varies between 150 and 300 V will be applied to the boost converter. The boost converter will boost the input voltage to a fixed 300 V DC. Next, this voltage is supplied to the single-phase full-bridge inverter to obtain 230 V AC. In the end, The output of the inverter will feed a freezer motor. The PV panels can be stand-alone or grid-connected. The grid-connected PV is divided into two categories, such as with a transformer and without a transformer, a transformer type has galvanic isolation resulting in increasing the security and also provides no further DC current toward the grid, but it is expensive, heavy and bulky. The transformerless type holds high efficiency and it is cheaper, but it suffers from leakage current between PV and the grid. This paper proposes a stand-alone direct use of PV to supply a freezer; therefore, no grid connection will result in no leakage current between the PV and Grid. The proposed circuit has some features such as no filtering circuit at the output of the inverter, no battery in the system, DC-link instead of AC link that reduces no-loads, having a higher efficiency, and holding enough energy in the DC-link capacitor to get the motor started. The circuit uses no transformers, thus, it is cheaper and has a smaller size. In addition, the system does not require a complex pulse width modulation (PWM) technique, because the motor can operate with a pulsed waveform. The control strategy uses the PWM signal with the desired timing. With this type of square wave, the harmonics (5th and 7th) of the voltage are reduced. The experimental and simulation results are presented to verify the feasibility of the proposed strategy

    Analysis and mitigation of dead time harmonics in the single-phase full-bridge PWM converters with repetitive controllers

    Get PDF
    In order to prevent the power switching devices (e.g., the Insulated-Gate-Bipolar-Transistor, IGBT) from shoot through in voltage source converters during a switching period, the dead time is added either in the hardware driver circuits of the IGBTs or implemented in software in Pulse-Width Modulation (PWM) schemes. Both solutions will contribute to a degradation of the injected current quality. As a consequence, the harmonics induced by the dead time (referred to as "dead time harmonics" hereafter) have to be compensated in order to achieve a satisfactory current quality as required by standards. In this paper, the emission mechanism of dead time harmonics in single-phase PWM inverters is thus presented considering the modulation schemes in details. More importantly, a repetitive controller has been adopted to eliminate the dead time effect in single-phase grid-connected PWM converters. The repetitive controller has been plugged into a proportional resonant-based fundamental current controller so as to mitigate the dead time harmonics and also maintain the control of the fundamental frequency grid current in terms of dynamics. Simulations and experiments are provided, which confirm that the repetitive controller can effectively compensate the dead time harmonics and other low-order distortions, and also it is a simple method without hardware modifications

    Multilevel Converters: An Enabling Technology for High-Power Applications

    Get PDF
    | Multilevel converters are considered today as the state-of-the-art power-conversion systems for high-power and power-quality demanding applications. This paper presents a tutorial on this technology, covering the operating principle and the different power circuit topologies, modulation methods, technical issues and industry applications. Special attention is given to established technology already found in industry with more in-depth and self-contained information, while recent advances and state-of-the-art contributions are addressed with useful references. This paper serves as an introduction to the subject for the not-familiarized reader, as well as an update or reference for academics and practicing engineers working in the field of industrial and power electronics.Ministerio de Ciencia y Tecnología DPI2001-3089Ministerio de Eduación y Ciencia d TEC2006-0386

    New Control Algorithms for the Distributed Generation Interface in Grid-Connected and Micro-grid Systems

    Get PDF
    Driven by economic, technical, and environmental reasons, the energy sector is moving into an era where large portions of increases in electrical energy demand will be met through widespread installation of distributed resources or what's known as distributed generation (DG). DG units can operate in parallel to the main grid or in a micro-grid mode. The later is formed by a cluster of DG units connected to a distribution network to maintain the reliability of critical loads, mainly when the grid supply is not available. Distributed resources include variable frequency sources, high frequency sources, and direct energy conversion sources producing dc voltages or currents. The majority of distributed resources are interfaced to the utility grid or to the customer load via dc-ac pulse-width-modulated (PWM) voltage source inverter (VSI) systems. However, these interfaces introduce new issues, such as the absence of the physical inertia, wide-band of dynamics, limited overload capability, susceptibility to parameters variation, and switching harmonics generation. In addition, the uncertain and dynamic nature of the distribution network challenges the stability and control effectiveness of a grid-connected inverter-based DG interface. Generally, difficulties appear in the form of grid impedance and interfacing parameter variations, fast and slow grid-voltage disturbances, grid distortion and unbalance, and interactions between the inverter ac-side filter and the grid. On the other hand, a micro-grid system will be dominated by inverter-based DG units. Unlike conventional power system generators, inverter-based DG units have no physical inertia. This fact makes the micro-grid system potentially susceptible to oscillations resulting from system disturbances. Severe and random disturbances might be initiated in a micro-grid system, due to load changes, the power sharing mechanism of the inverters and other generators, and interactions between the DG interface and the network. Motivated by the aforementioned difficulties, this thesis presents new control algorithms for the DG interface that guarantee stable and high power quality injection under the occurrence of network disturbances and uncertainties, in both the grid-connected and micro-grid systems. The control architecture of the proposed DG interface relies on the following subsystems. First, a newly designed deadbeat current regulation scheme is proposed. The proposed design guarantees high power quality current injection under the presence of different disturbing parameters such as grid voltage distortion, interfacing parameter variation, and inverter system delays. Further, it utilizes the maximum dynamic performance of the inverter in a way that provides a high bandwidth and decoupled control performance for the outer control loops. Different topologies of the ac-side filter are considered for the current control design. Second, a novel adaptive discrete-time grid-voltage sensorless interfacing scheme for DG inverters is proposed. The adaptive interface relies on a new interface-monitoring unit that is developed to facilitate accurate and fast estimation of the interfacing impedance parameters and the grid voltage vector (magnitude and position) at the point of common coupling. The estimated grid voltage is utilized to realize a grid-voltage sensorless interfacing scheme, whereas the interfacing parameters are utilized for the self-tuning control and interface-parameter monitoring. Further, a simple and robust synchronization algorithm and a voltage-sensorless average power control loop are proposed to realize an adaptive voltage-sensorless DG interface. The voltage-sensorless interface positively contributes to the elimination of the residual negative sequence and voltage feed-forward compensation errors, and to the robustness of the power sharing mechanism in paralleled inverter systems, where the power-sharing mechanism is generally based on open-loop controllers. Third, a new voltage control scheme for the DG interface featuring fast load voltage regulation and effective mitigation of fast voltage disturbances is proposed. The proposed voltage control scheme targets the problem of fast and large-signal-based voltage disturbances, which is common in typical distribution feeders. A hybrid voltage controller combining a linear with a variable-structure-control element is proposed for the DG interface. Positive and dual-sequence versions of the proposed voltage controller are developed to address the issue of unbalanced voltage disturbances. The proposed voltage controller successfully embeds a wide band of frequency modes through an equivalent internal model. Subsequently, wide range of balanced and unbalanced voltage perturbations, including capacitor-switching disturbances, can be effectively mitigated. Fourth, to constrain the drift of the low frequency modes in a conventional droop-controlled micro-grid, a new transient-based droop controller with adaptive transient-gains is proposed. The proposed power-sharing controller offers an active damping feature that is designed to preserve the dynamic performance and stability of each inverter unit at different loading conditions. Unlike conventional droop controllers, the proposed droop controller yields two-degree of freedom tunable controller. Subsequently, the dynamic performance of the power-sharing mechanism can be adjusted, without affecting the static droop gain, to damp the oscillatory modes of the power-sharing controller. The overall robust DG interface facilitates a robust micro-grid operation and safe plug-and-play integration of DG units on existing distribution systems; hence increasing the system penetration of DG. The direct result of this development is huge financial saving for utilities by capturing the salient features of deploying DG into existing utility networks. Further, these developments are significant to the industry as they provide the blue print for reliable control algorithms in future DG units, which are expected to operate under challenging system conditions

    Frequency Control of Wind and PV Based Isolated Microgrid

    Get PDF
    The wind and solar PV based isolated microgrid can be economical and reliable for the remote area where the grid is not available. The frequency and voltage fluctuation are major problems in such remote microgrid due to intermittent nature of renewable resources like wind and solar PV. The frequency fluctuation should remain within acceptable limits for stable operation of the remote microgrid. This thesis work focuses on frequency control of wind and photovoltaic (PV) based isolated micro-grid using traditional droop control technique. The battery system acts as a master unit which is responsible for setting up the common AC bus voltage and frequency. The proportionalresonant (PR) voltage and current controllers are designed to control the current and voltage output of the voltage source inverter (VSI) connected with the DC battery. The better control performance can be obtained by using PR controller which easily tracks reference signal and eliminates steady state error in resonant frequency. The traditional droop control method is applied to generate voltage and the frequency reference set points for the VSI controller to control frequency of the AC micro-grid. The detailed analysis of the frequency control is performed by conducting two different case studies and load sharing between inverters is also presented to observe power shared by different inverters in isolated microgrid. In all the cases, system frequency is maintained within the acceptable range for the stable operation of wind and solar PV based isolated microgrid

    Requirements to Testing of Power System Services Provided by DER Units

    Get PDF
    The present report forms the Project Deliverable ‘D 2.2’ of the DERlab NoE project, supported by the EC under Contract No. SES6-CT-518299 NoE DERlab. The present document discuss the power system services that may be provided from DER units and the related methods to test the services actually provided, both at component level and at system level

    Reliability analysis of single-phase photovoltaic inverters with reactive power support

    Get PDF
    Reactive power support is expected to be an emerging ancillary requirement for single-phase photovoltaic (PV) inverters. This work assesses related reliability issues and focuses on the second stage or inversion process in PV inverters. Three PV inverter topologies are analyzed and their reliability is determined on a component-by-component level. Limiting operating points are considered for each of these topologies. The capacitor in the dc link, the MOSFETs in the inverting bridge, and the output filter are the components affected. Studies show that varying power-factor operation with a constant real power output increases the energy storage requirement as well as the capacitance required in the dc link in order to produce the double-frequency power ripple. The overall current rating of the MOSFETs and output filter must also be sized to accommodate the current for the apparent power output. Modeling of the inverter verifies the conditions for each of the components under varying reactive power support commands. It is shown that the production of reactive power can significantly increase the capacitance requirement, but the limiting reliability issue comes from the increased output current rating of the MOSFETs
    corecore