21,658 research outputs found

    Vertical facing panel-joint gap analysis for steel-seinforced soil walls

    Get PDF
    This paper reports the results of a numerical parametric study focused on the prediction of vertical load distribution and vertical gap compression between precast concrete facing panel units in steel-reinforced soil walls ranging in height from 6 to 24 m. The vertical compression was accommodated by polymeric bearing pads placed at the horizontal joints between panels during construction. This paper demonstrates how gap compression and magnitude of vertical load transmitted between horizontal joints are influenced by joint location along the height of the wall, joint compressibility, and backfill and foundation soil stiffness. The summary plots in this study can be used to estimate the number and type (stiffness) of the bearing pads to ensure a target minimum gap thickness at the end of construction, to demonstrate the relative influence of wall height and different material component properties on vertical load levels and gap compression, or as a benchmark to test numerical models used for project-specific design. The paper also demonstrates that although the load factor (ratio of vertical load at a horizontal joint to weight of panels above the joint) and joint compression are relatively insensitive to foundation stiffness, the total settlement at the top of the wall facing is very sensitive to foundation stiffness. This paper examines the quantitative consequences of using a simple linear compressive stress–strain model for the bearing pads versus amultilinear model that is better able to capture the response of bearing pads taken to greater compression. The study demonstrates that qualitative trends in vertical load factor are preserved when a more advanced stress-dependent stiffness soil hardening model is used for the backfill soil as compared with the simpler linear elastic Mohr–Coulomb model. Although there were differences in vertical loads and gap compressionwith the use of both soilmodels for the backfill, the differenceswere small and not of practical concern.Peer ReviewedPostprint (author's final draft

    Generic, Geometric Finite Element Analysis of the Transtibial Residual Limb and Prosthetic Socket

    Get PDF
    Finite element analysis was used to investigate the stress distribution between the residual limb and prosthetic socket of persons with transtibial amputation (TTA). The purpose of this study was to develop a tool to provide a quantitative estimate of prosthetic interface pressures to improve our understanding of residual limb/prosthetic socket biomechanics and prosthetic fit. FE models of the residual limb and prosthetic socket were created. In contrast to previous FE models of the prosthetic socket/residual limb system, these models were not based on the geometry of a particular individual, but instead were based on a generic, geometric approximation of the residual limb. These models could then be scaled for the limbs of specific individuals. The material properties of the bulk soft tissues of the residual limb were based upon local in vivo indentor studies. Significant effort was devoted toward the validation of these generic, geometric FE models; prosthetic interface pressures estimated via the FE model were compared to experimentally determined interface pressures for several persons with TTA in a variety of socket designs and static load/alignment states. The FE normal stresses were of the same order of magnitude as the measured stresses (0-200 kPa); however, significant differences in the stress distribution were observed. Although the generic, geometric FE models do not appear to accurately predict the stress distribution for specific subjects, the models have practical applications in comparative stress distribution studies

    Performance of the resurfaced hip. Part 1: the influence of the prosthesis size and positioning on the remodelling and fracture of the femoral neck

    No full text
    Hip resurfacing is an established treatment for osteoarthritis in young active patients. Failure modes include femoral neck fracture and prosthesis loosening, which may be associated with medium-term bone adaptation, including femoral neck narrowing and densification around the prosthesis stem.Finite element modelling was used to indicate the effects of prosthesis sizing and positioning on the bone remodelling and fracture strength under a range of normal and traumatic loads, with the aim of understanding these failure modes better.The simulations predicted increased superior femoral neck stress shielding in young patients with small prostheses, which required shortening of the femoral neck to give an acceptable implant–bone interface. However, with a larger prosthesis, natural femoral head centre recreation in the implanted state was possible; therefore stress shielding was restricted to the prosthesis interior, and its extent was less sensitive to prosthesis orientation. With valgus orientation, the implanted neck strength was, at worst, within 3 per cent of its intact strength.The study suggests that femoral neck narrowing may be linked to a reduction in the horizontal femoral offset, occurring if the prosthesis is excessively undersized. As such, hip resurfacing should aim to reproduce the natural femoral head centre, and, for valgus prosthesis orientation, to avoid femoral neck fracture

    Meso-scale modelling of 3D woven composite T-joints with weave variations

    Get PDF
    A meso-scale modelling framework is proposed to simulate the 3D woven fibre architectures and the mechanical performance of the composite T-joints, subjected to quasi-static tensile pull-off loading. The proposed method starts with building the realistic reinforcement geometries of the 3D woven T-joints at the mesoscale, of which the modelling strategy is applicable for other types of geometries with weave variations at the T-joint junction. Damage modelling incorporates both interface and constituent material damage, in conjunction with a continuum damage mechanics approach to account for the progressive failure behaviour. With a voxel based cohesive zone model, the proposed method is able to model mode I delamination based on the voxel mesh technique, which has advantages in meshing. Predicted results are in good agreement with experimental data beyond initial failure, in terms of load-displacement responses, failure events, damage initiation and propagation. The significant effect of fibre architecture variations on mechanical behaviour is successfully predicted through this modelling method without any further correlation of input parameters in damage model. This predictive method will facilitate the design and optimisation of 3D woven T-joint preforms

    Large-scale structural analysis: The structural analyst, the CSM Testbed and the NAS System

    Get PDF
    The Computational Structural Mechanics (CSM) activity is developing advanced structural analysis and computational methods that exploit high-performance computers. Methods are developed in the framework of the CSM testbed software system and applied to representative complex structural analysis problems from the aerospace industry. An overview of the CSM testbed methods development environment is presented and some numerical methods developed on a CRAY-2 are described. Selected application studies performed on the NAS CRAY-2 are also summarized

    Parametric Analysis Using the Finite Element Method to Investigate Prosthetic Interface Stresses for Persons with Trans-tibial Amputation

    Get PDF
    A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance. This model was based upon geometric approximations of anthropometric residual limb geometry. The model was not specific to an individual with amputation, but could be scaled to approximate the limb of a particular subject. Parametric analyses were conducted to investigate the effects of prosthetic socket design and residual limb geometry on the residual limb/prosthetic socket interface stresses. Behavioral trends were illustrated via sensitivity analysis. The results of the parametric analyses indicate that the residual limb/prosthetic socket interface stresses are affected by variations in both prosthetic design and residual limb geometry. Specifically, the analyses indicate : 1) the residual limb/prosthetic liner interface pressures are relatively insensitive to the socket stiffness ; 2) the stiffness of the prosthetic liner influences the interface stress distribution for both the unrectified and patellar-tendon-bearing (PTB) rectified models-- the external load state appears to influence the interface pressure distribution, while the prosthetic socket rectification appears to influence the interface shear stress distribution ; 3) the interface pressures are - very sensitive to the prosthetic rectification ; 4) the shape and relative bulk of soft tissue may significantly influence the interface pressure distribution ; 5) the interface pressure distribution is also influenced by the residual limb length; and 6) the stiffness/compliance of the residual limb soft tissues may significantly alter the interface pressure distribution
    • …
    corecore