83 research outputs found

    Drift Correction Methods for gas Chemical Sensors in Artificial Olfaction Systems: Techniques and Challenges

    Get PDF
    In this chapter the authors introduce the main challenges faced when developing drift correction techniques and will propose a deep overview of state-of-the-art methodologies that have been proposed in the scientific literature trying to underlying pros and cons of these techniques and focusing on challenges still open and waiting for solution

    Design Issues and Challenges of File Systems for Flash Memories

    Get PDF
    This chapter discusses how to properly address the issues of using NAND flash memories as mass-memory devices from the native file system standpoint. We hope that the ideas and the solutions proposed in this chapter will be a valuable starting point for designers of NAND flash-based mass-memory devices

    Exploiting Evolution for an Adaptive Drift-Robust Classifier in Chemical Sensing

    Get PDF
    Gas chemical sensors are strongly affected by drift, i.e., changes in sensors' response with time, that may turn statistical models commonly used for classification completely useless after a period of time. This paper presents a new classifier that embeds an adaptive stage able to reduce drift effects. The proposed system exploits a state-of-the-art evolutionary strategy to iteratively tweak the coefficients of a linear transformation able to transparently transform raw measures in order to mitigate the negative effects of the drift. The system operates continuously. The optimal correction strategy is learnt without a-priori models or other hypothesis on the behavior of physical-chemical sensors. Experimental results demonstrate the efficacy of the approach on a real problem

    Non-linear Machine Learning with Active Sampling for MOX Drift Compensation

    Get PDF
    Abstract—Metal oxide (MOX) gas detectors based on SnO2 provide low-cost solutions for real-time sensing of complex gas mixtures for indoor ambient monitoring. With high sensitivity under ideal conditions, MOX detectors may have poor longterm response accuracy due to environmental factors (humidity and temperature) along with sensor aging, leading to calibration drifts. Finding a simple and efficient solution to correct such calibration drifts has been the subject of numerous studies but remains an open problem. In this work, we present an efficient approach to MOX calibration using active and transfer sampling techniques coupled with non-linear machine learning algorithms, namely neural networks, extreme gradient boosting (XGBoost) and radial kernel support vector machines (SVM). Applied on the UCI’s HT detectors dataset, the study evaluates methods for active sampling, makes an assessment of suitable neural networks architectures and compares the performance of neural networks, XGBoost and radial kernel SVM to classify gas mixtures (banana and wine odours, clean air) in the presence of humidity and temperature changes. The results show high classification accuracy levels (above 90%) and confirm that active sampling can provide a suitable solution. Index Terms—Neural Networks, Extreme Gradient Boosting, XGBoost, Support Vector Machines, Non-Linear Learning Methods, Machine Learnin

    Signal and data processing for machine olfaction and chemical sensing: A review

    Get PDF
    Signal and data processing are essential elements in electronic noses as well as in most chemical sensing instruments. The multivariate responses obtained by chemical sensor arrays require signal and data processing to carry out the fundamental tasks of odor identification (classification), concentration estimation (regression), and grouping of similar odors (clustering). In the last decade, important advances have shown that proper processing can improve the robustness of the instruments against diverse perturbations, namely, environmental variables, background changes, drift, etc. This article reviews the advances made in recent years in signal and data processing for machine olfaction and chemical sensing

    Orthogonal Signal Correction to Improve Stability Regression Model in Gas Sensor Systems

    Get PDF
    Metal oxide sensors are the most often used in electronic nose devices because of their high sensitivity, long lifetime, and low cost. However, these sensors suffer from a lack of response stability making the electronic nose systems useless in industrial applications. The sensor instabilities are particularly caused by incomplete recovery process producing gradual drifts in the sensor responses. This paper focuses on a signal processing method combining baseline manipulation and orthogonal signal correction technique in order to reduce effectively the drift impact from the sensor outputs. The proposed signal processing is explored using experimental data obtained from a gas sensor array responding to various concentrations of pine essential oil vapors. Partial Least Square method is then applied on the corrected dataset to establish a regression model for the estimation of gas concentration. In this work, we show essentially how our drift correction approach can help to improve significantly the stability of the regression model, while ensuring good accuracy

    Artificial Olfaction in the 21st Century

    Get PDF
    The human olfactory system remains one of the most challenging biological systems to replicate. Humans use it without thinking, where it can measure offer protection from harm and bring enjoyment in equal measure. It is the system's real-time ability to detect and analyze complex odors that makes it difficult to replicate. The field of artificial olfaction has recruited and stimulated interdisciplinary research and commercial development for several applications that include malodor measurement, medical diagnostics, food and beverage quality, environment and security. Over the last century, innovative engineers and scientists have been focused on solving a range of problems associated with measurement and control of odor. The IEEE Sensors Journal has published Special Issues on olfaction in 2002 and 2012. Here we continue that coverage. In this article, we summarize early work in the 20th Century that served as the foundation upon which we have been building our odor-monitoring instrumental and measurement systems. We then examine the current state of the art that has been achieved over the last two decades as we have transitioned into the 21st Century. Much has been accomplished, but great progress is needed in sensor technology, system design, product manufacture and performance standards. In the final section, we predict levels of performance and ubiquitous applications that will be realized during in the mid to late 21st Century

    Calibration transfer and drift counteraction in chemical sensor arrays using Direct Standardization

    Get PDF
    Inherent variability of chemical sensors makes it necessary to calibrate chemical detection systems individually. This shortcoming has traditionally limited usability of systems based on metal oxide gas sensor arrays and prevented mass-production for some applications. Here, aiming at exploring calibration transfer between chemical sensor arrays, we exposed five twin 8-sensor detection units to different concentration levels of ethanol, ethylene, carbon monoxide, or methane. First, we built calibration models using data acquired with a master unit. Second, to explore the transferability of the calibration models, we used Direct Standardization to map the signals of a slave unit to the space of the master unit in calibration. In particular, we evaluated the transferability of the calibration models to other detection units, and within the same unit measuring days apart. Our results show that signals acquired with one unit can be successfully mapped to the space of a reference unit. Hence, calibration models trained with a master unit can be extended to slave units using a reduced number of transfer samples, diminishing thereby calibration costs. Similarly, signals of a sensing unit can be transformed to match sensor behavior in the past to mitigate drift effects. Therefore, the proposed methodology can reduce calibration costs in mass-production and delay recalibrations due to sensor aging. Acquired dataset is made publicly available

    Classification of Two Volatiles Using an eNose Composed by an Array of 16 Single-Type Miniature Micro-Machined Metal-Oxide Gas Sensors

    Get PDF
    The artificial replication of an olfactory system is currently an open problem. The development of a portable and low-cost artificial olfactory system, also called electronic nose or eNose, is usually based on the use of an array of different gas sensors types, sensitive to different target gases. Low-cost Metal-Oxide semiconductor (MOX) gas sensors are widely used in such arrays. MOX sensors are based on a thin layer of silicon oxide with embedded heaters that can operate at different temperature set points, which usually have the disadvantages of different volatile sensitivity in each individual sensor unit and also different crossed sensitivity to different volatiles (unspecificity). This paper presents and eNose composed by an array of 16 low-cost BME680 digital miniature sensors embedding a miniature MOX gas sensor proposed to unspecifically evaluate air quality. In this paper, the inherent variability and unspecificity that must be expected from the 16 embedded MOX gas sensors, combined with signal processing, are exploited to classify two target volatiles: ethanol and acetone. The proposed eNose reads the resistance of the sensing layer of the 16 embedded MOX gas sensors, applies PCA for dimensional reduction and k-NN for classification. The validation results have shown an instantaneous classification success higher than 94% two days after the calibration and higher than 70% two weeks after, so the majority classification of a sequence of measures has been always successful in laboratory conditions. These first validation results and the low-power consumption of the eNose (0.9 W) enables its future improvement and its use in portable and battery-operated applications
    corecore