791 research outputs found

    Intra-Body Communications for Nervous System Applications: Current Technologies and Future Directions

    Full text link
    The Internet of Medical Things (IoMT) paradigm will enable next generation healthcare by enhancing human abilities, supporting continuous body monitoring and restoring lost physiological functions due to serious impairments. This paper presents intra-body communication solutions that interconnect implantable devices for application to the nervous system, challenging the specific features of the complex intra-body scenario. The presented approaches include both speculative and implementative methods, ranging from neural signal transmission to testbeds, to be applied to specific neural diseases therapies. Also future directions in this research area are considered to overcome the existing technical challenges mainly associated with miniaturization, power supply, and multi-scale communications.Comment: https://www.sciencedirect.com/science/article/pii/S138912862300163

    A survey on wireless body area networks for eHealthcare systems in residential environments

    Get PDF
    The progress in wearable and implanted health monitoring technologies has strong potential to alter the future of healthcare services by enabling ubiquitous monitoring of patients. A typical health monitoring system consists of a network of wearable or implanted sensors that constantly monitor physiological parameters. Collected data are relayed using existing wireless communication protocols to the base station for additional processing. This article provides researchers with information to compare the existing low-power communication technologies that can potentially support the rapid development and deployment of WBAN systems, and mainly focuses on remote monitoring of elderly or chronically ill patients in residential environments

    In-body Communications Exploiting Light:A Proof-of-concept Study Using ex vivo Tissue Samples

    Get PDF
    This article presents a feasibility study on the transmission of information through the biological tissues exploiting light. The experimental results demonstrating the potentials of optical wireless communications through biological tissues (OCBT) are presented. The main application of the proposed technology is in-body communications, where wireless connectivity needs to be provided to implanted electronic devices, such as pacemakers, cardiac defibrillators, and smart pills, for instance. Traditionally, in-body communications are performed using radio and acoustic waves. However, light has several fundamental advantages making the proposed technology highly attractive for this purpose. In particular, optical communications are highly secure, private, safe, and in many cases, extremely simple with the potential of low-power implementation. In the experiments, near-infrared light was used, as the light propagation in biotissues is more favorable in this part of the spectrum. The amount of light exposure given to biotissues was controlled to keep it within the safety limits. Information transmission experiments were carried out with the temperature-controlled ex vivo samples of porcine tissue. The tissue temperature was found to be significantly affecting the light propagation process. Communication performance with respect to the biotissue thickness and light direction was assessed. The results showed that optical channels to and from the possible implant are nearly reciprocal. Communication links were established to the deepness of more than four centimeters, and the data rates of up to 100 Kbps were obtained. The encouraging results of this study allow us to anticipate the potential applications of the proposed light-based technology to communicate with the various electronic devices implanted at different depths in the human body

    EMC, RF, and Antenna Systems in Miniature Electronic Devices

    Get PDF

    On the Recognition of Emotion from Physiological Data

    Get PDF
    This work encompasses several objectives, but is primarily concerned with an experiment where 33 participants were shown 32 slides in order to create ‗weakly induced emotions‘. Recordings of the participants‘ physiological state were taken as well as a self report of their emotional state. We then used an assortment of classifiers to predict emotional state from the recorded physiological signals, a process known as Physiological Pattern Recognition (PPR). We investigated techniques for recording, processing and extracting features from six different physiological signals: Electrocardiogram (ECG), Blood Volume Pulse (BVP), Galvanic Skin Response (GSR), Electromyography (EMG), for the corrugator muscle, skin temperature for the finger and respiratory rate. Improvements to the state of PPR emotion detection were made by allowing for 9 different weakly induced emotional states to be detected at nearly 65% accuracy. This is an improvement in the number of states readily detectable. The work presents many investigations into numerical feature extraction from physiological signals and has a chapter dedicated to collating and trialing facial electromyography techniques. There is also a hardware device we created to collect participant self reported emotional states which showed several improvements to experimental procedure

    Vehicle electrification: technologies, challenges and a global perspective for smart grids

    Get PDF
    Nowadays, due to economic and climate concerns, the private transportation sector is shifting for the vehicle electrification, mainly supported by electric and hybrid plug-in vehicles. For this new reality, new challenges about operation modes are emerging, demanding a cooperative and dynamic operation with the electrical power grid, guaranteeing a stable integration without omitting the power quality for the grid-side and for the vehicle-side. Besides the operation modes, new attractive and complementary technologies are offered by the vehicle electrification in the context of smart grids, which are valid for both on-board and off-board systems. In this perspective, this book chapter presents a global perspective and deals with challenges for the vehicle electrification, covering the key technologies toward a sustainable future. Among others, the flowing topics are covered: (1) Overview of power electronics structures for battery charging systems, including on-board and off-board systems; (2) State-of-the-art of communication technologies for application in the context of vehicular electrification, smart grids and smart homes; (3) Challenges and opportunities concerning wireless power transfer with bidirectional interface to the electrical grid; (4) Future perspectives about bidirectional power transfer between electric vehicles (vehicle-to-vehicle operation mode); (5) Unified technologies, allowing to combine functionalities of a bidirectional interface with the electrical grid and motor driver based on a single system; and (6) Smart grids and smart homes scenarios and accessible opportunities about operation modes.Fundação para a Ciência e Tecnologia (FCT

    Revealing the Secrets of Radio-Enabled Embedded Systems: on extraction of raw information from any on-board signal through RF

    Get PDF
    In this work we are interested in evaluating the possibility of extracting information from radio-enabled embedded-systems from a long distance. That is, our focus is capturing information from sources in the micrometer to tens of centimeters scale, such as intra- or inter- device busses, board-level routing traces etc. Moreover, we focus on distances in the range of millimeters to tens of centimeters from the (on-chip or on-board) embedded-system Tx Antenna to the signal source. Side-channels denotes presence of information in illegitimate channels. Side-channel analysis (SCA) attacks typically require statistical analysis and many leakage traces, focusing on micrometer level signals (sources) which emanate direct Near-Field information up to centimeters-level distances. In the same context (Near-Field and micrometer-level) simple power analysis (SPA) like attacks typically extract either direct raw information from one or few leakages or utilize statistical analysis on various samples from the same trace, similarly to horizontal attacks. Lately, radio-enabled systems were shown to emanate to a large distance (Far-Field), information from micrometer level sources, such as CPU processing, through the RF Tx Antenna: so far, SCA-like statistical analysis were shown. On the other hand, various reports exist on direct information eavesdropping/ sniffing or data exfiltration, emanated from centimeter to tens of centimeters scale sources, e.g., SATA, USB, Power-lines, Serial interface, Air-Gap systems, Screens and even optical fibers. All these elements are typically being used as a source and a direct Tx Antenna (huge, several to tens of centimeters) of the sensitive information. These antennas typically transmit information to short distances and the decay is very steep (proportional to r2r^{-2}-r3r^{-3} depending on various factors and models). To the best of our knowledge, we report here for the first time an alarming security challenge: any signal in the embedded system, from serial ports, DMA-controlled memory-access, JTAG and SPI interfaces, on-board signals with galvanic connection to the Tx Antenna-chip and \emph{on-board signals without galvanic connection to the Tx Antenna-chip itself, all leak direct information up to tens of centimeters from source to the Tx Antenna}. This alarming situation induce signal-integrity implications within the embedded system, and significant implications relating to device-isolation and user-isolation, it may also affect standards and specifications for e.g., electromagnetic compatibility (EMC), on-board signal shielding, electromagnetic and RF interference (EMI, RFI), cross-talk, and generally design-for-manufacturing (DFM) guidelines for both intra-IC and PCB board. We demonstrate such direct readout of signals with commercial and low-cost equipment indicating how problematic the situation is. The existence of such leakage is demonstrated both over an ultra-low-cost platform such as the nRF52832(nRF) embedded-system and on a more advanced ESP32-c3-devkitc-02 board which is far more widespread in ISM radio applications and meets certification like FCC and CE (as compared to the nRF device). We have constructed an experiment to demonstrate leakage scenarios from (1) on- and (2) off-chip, on-board or (3) signals without galvanic connection to the RF front-end chip, showing the severity of the leakage, repetitively and systematic nature of the phenomena over various devices. We further demonstrate how sophisticated adversaries can build a code-injection Gadget which can carry sensitive-data and modulate it to be best extracted by the RF-channel. The main observation we push forward is that unless concrete interference and isolation standards appear with security metrics in mind, which are significantly different than ones needed for communication, it would be hard to prevent such leakages
    corecore