318 research outputs found

    Haptic data reduction through dynamic perceptual analysis and event-based communication

    Full text link
    This research presents an adjustable and flexible framework for haptic data compression and communication that can be used in a robotic teleoperation session. The framework contains a customized event-driven transmission control protocol, several dynamically adaptive perceptual and prediction methods for haptic sample reduction, and last but not the least, an architecture for the data flow

    Character Recognition

    Get PDF
    Character recognition is one of the pattern recognition technologies that are most widely used in practical applications. This book presents recent advances that are relevant to character recognition, from technical topics such as image processing, feature extraction or classification, to new applications including human-computer interfaces. The goal of this book is to provide a reference source for academic research and for professionals working in the character recognition field

    Human-robot interaction using a behavioural control strategy

    Get PDF
    PhD ThesisA topical and important aspect of robotics research is in the area of human-robot interaction (HRI), which addresses the issue of cooperation between a human and a robot to allow tasks to be shared in a safe and reliable manner. This thesis focuses on the design and development of an appropriate set of behaviour strategies for human-robot interactive control by first understanding how an equivalent human-human interaction (HHI) can be used to establish a framework for a robotic behaviour-based approach. To achieve the above goal, two preliminary HHI experimental investigations were initiated in this study. The first of which was designed to evaluate the human dynamic response using a one degree-of-freedom (DOF) HHI rectilinear test where the handler passes a compliant object to the receiver along a constrained horizontal path. The human dynamic response while executing the HHI rectilinear task has been investigated using a Box-Behnken design of experiments [Box and Hunter, 1957] and was based on the McRuer crossover model [McRuer et al. 1995]. To mimic a real-world human-human object handover task where the handler is able to pass an object to the receiver in a 3D workspace, a second more substantive one DOF HHI baton handover task has been developed. The HHI object handover tests were designed to understand the dynamic behavioural characteristics of the human participants, in which the handler was required to dexterously pass an object to the receiver in a timely and natural manner. The profiles of interactive forces between the handler and receiver were measured as a function of time, and how they are modulated whilst performing the tasks, was evaluated. Three key parameters were used to identify the physical characteristics of the human participants, including: peak interactive force (fmax), transfer time (Ttrf), and work done (W). These variables were subsequently used to design and develop an appropriate set of force and velocity control strategies for a six DOF Stäubli robot manipulator arm (TX60) working in a human-robot interactive environment. The optimal design of the software and hardware controller implementation for the robot system has been successfully established in keeping with a behaviour-based approach. External force control based on proportional plus integral (PI) and fuzzy logic control (FLC) algorithms were adopted to control the robot end effector velocity and interactive force in real-time. ii The results of interactive experiments with human-to-robot and robot-to-human handover tasks allowed a comparison of the PI and FLC control strategies. It can be concluded that the quantitative measurement of the performance of robot velocity and force control can be considered acceptable for human-robot interaction. These can provide effective performance during the robot-human object handover tasks, where the robot was able to successfully pass the object from/to the human in a safe, reliable and timely manner. However, after careful analysis with regard to human-robot handover test results, the FLC scheme was shown to be superior to PI control by actively compensating for the dynamics in the non-linear system and demonstrated better overall performance and stability. The FLC also shows superior performance in terms of improved sensitivity to small error changes compared to PI control, which is an advantage in establishing effective robot force control. The results of survey responses from the participants were in agreement with the parallel test outcomes, demonstrating significant satisfaction with the overall performance of the human-robot interactive system, as measured by an average rating of 4.06 on a five point scale. In brief, this research has contributed the foundations for long-term research, particularly in the development of an interactive real-time robot-force control system, which enables the robot manipulator arm to cooperate with a human to facilitate the dextrous transfer of objects in a safe and speedy manner.Thai government and Prince of Songkla University (PSU

    Computational Intelligence in Electromyography Analysis

    Get PDF
    Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. EMG may be used clinically for the diagnosis of neuromuscular problems and for assessing biomechanical and motor control deficits and other functional disorders. Furthermore, it can be used as a control signal for interfacing with orthotic and/or prosthetic devices or other rehabilitation assists. This book presents an updated overview of signal processing applications and recent developments in EMG from a number of diverse aspects and various applications in clinical and experimental research. It will provide readers with a detailed introduction to EMG signal processing techniques and applications, while presenting several new results and explanation of existing algorithms. This book is organized into 18 chapters, covering the current theoretical and practical approaches of EMG research

    U-Limb: A multi-modal, multi-center database on arm motion control in healthy and post-stroke conditions

    Get PDF
    BACKGROUND: Shedding light on the neuroscientific mechanisms of human upper limb motor control, in both healthy and disease conditions (e.g., after a stroke), can help to devise effective tools for a quantitative evaluation of the impaired conditions, and to properly inform the rehabilitative process. Furthermore, the design and control of mechatronic devices can also benefit from such neuroscientific outcomes, with important implications for assistive and rehabilitation robotics and advanced human-machine interaction. To reach these goals, we believe that an exhaustive data collection on human behavior is a mandatory step. For this reason, we release U-Limb, a large, multi-modal, multi-center data collection on human upper limb movements, with the aim of fostering trans-disciplinary cross-fertilization. CONTRIBUTION: This collection of signals consists of data from 91 able-bodied and 65 post-stroke participants and is organized at 3 levels: (i) upper limb daily living activities, during which kinematic and physiological signals (electromyography, electro-encephalography, and electrocardiography) were recorded; (ii) force-kinematic behavior during precise manipulation tasks with a haptic device; and (iii) brain activity during hand control using functional magnetic resonance imaging

    Active haptic exploration for 3D shape reconstruction.

    Get PDF
    by Fung Wai Keung.Thesis (M.Phil.)--Chinese University of Hong Kong, 1996.Includes bibliographical references (leaves 146-151).Acknowledgements --- p.viiiAbstract --- p.1Chapter 1 --- Overview --- p.3Chapter 1.1 --- Tactile Sensing in Human and Robot --- p.4Chapter 1.1.1 --- Human Hands and Robotic Hands --- p.4Chapter 1.1.2 --- Mechanoreceptors in skin and Tactile Sensor Arrays --- p.7Chapter 1.2 --- Motivation --- p.12Chapter 1.3 --- Objectives --- p.13Chapter 1.4 --- Related Work --- p.14Chapter 1.4.1 --- Using Vision Alone --- p.15Chapter 1.4.2 --- Integration of Vision and Touch --- p.15Chapter 1.4.3 --- Using Touch Sensing Alone --- p.17Chapter 1.4.3.1 --- Ronald S. Fearing's Work --- p.18Chapter 1.4.3.2 --- Peter K. Allen's Work --- p.22Chapter 1.5 --- Outline --- p.26Chapter 2 --- Geometric Models --- p.27Chapter 2.1 --- Introduction --- p.27Chapter 2.2 --- Superquadrics --- p.27Chapter 2.2.1 --- 2D Superquadrics --- p.27Chapter 2.2.2 --- 3D Superquadrics --- p.29Chapter 2.3 --- Model Recovery of Superquadric Models --- p.31Chapter 2.3.1 --- Problem Formulation --- p.31Chapter 2.3.2 --- Least Squares Optimization --- p.33Chapter 2.4 --- Free-Form Deformations --- p.34Chapter 2.4.1 --- Bernstein Basis --- p.36Chapter 2.4.2 --- B-Spline Basis --- p.38Chapter 2.5 --- Other Geometric Models --- p.41Chapter 2.5.1 --- Generalized Cylinders --- p.41Chapter 2.5.2 --- Hyperquadrics --- p.42Chapter 2.5.3 --- Polyhedral Models --- p.44Chapter 2.5.4 --- Function Representation --- p.45Chapter 3 --- Sensing Strategy --- p.54Chapter 3.1 --- Introduction --- p.54Chapter 3.2 --- Sensing Algorithm --- p.55Chapter 3.2.1 --- Assumption of objects --- p.55Chapter 3.2.2 --- Haptic Exploration Procedures --- p.56Chapter 3.3 --- Contour Tracing --- p.58Chapter 3.4 --- Tactile Sensor Data Preprocessing --- p.59Chapter 3.4.1 --- Data Transformation and Sensor Calibration --- p.60Chapter 3.4.2 --- Noise Filtering --- p.61Chapter 3.5 --- Curvature Determination --- p.64Chapter 3.6 --- Step Size Determination --- p.73Chapter 4 --- 3D Shape Reconstruction --- p.80Chapter 4.1 --- Introduction --- p.80Chapter 4.2 --- Correspondence Problem --- p.81Chapter 4.2.1 --- Affine Invariance Property of B-splines --- p.84Chapter 4.2.2 --- Point Inversion Problem --- p.87Chapter 4.3 --- Parameter Triple Interpolation --- p.91Chapter 4.4 --- 3D Object Shape Reconstruction --- p.94Chapter 4.4.1 --- Heuristic Approach --- p.94Chapter 4.4.2 --- Closed Contour Recovery --- p.97Chapter 4.4.3 --- Control Lattice Recovery --- p.102Chapter 5 --- Implementation --- p.105Chapter 5.1 --- Introduction --- p.105Chapter 5.2 --- Implementation Tool - MATLAB --- p.105Chapter 5.2.1 --- Optimization Toolbox --- p.107Chapter 5.2.2 --- Splines Toolbox --- p.108Chapter 5.3 --- Geometric Model Implementation --- p.109Chapter 5.3.1 --- FFD Examples --- p.111Chapter 5.4 --- Shape Reconstruction Implementation --- p.112Chapter 5.5 --- 3D Model Reconstruction Examples --- p.120Chapter 5.5.1 --- Example 1 --- p.120Chapter 5.5.2 --- Example 2 --- p.121Chapter 6 --- Conclusion --- p.128Chapter 6.1 --- Future Work --- p.129Appendix --- p.133Bibliography --- p.14

    Navigation system based in motion tracking sensor for percutaneous renal access

    Get PDF
    Tese de Doutoramento em Engenharia BiomédicaMinimally-invasive kidney interventions are daily performed to diagnose and treat several renal diseases. Percutaneous renal access (PRA) is an essential but challenging stage for most of these procedures, since its outcome is directly linked to the physician’s ability to precisely visualize and reach the anatomical target. Nowadays, PRA is always guided with medical imaging assistance, most frequently using X-ray based imaging (e.g. fluoroscopy). Thus, radiation on the surgical theater represents a major risk to the medical team, where its exclusion from PRA has a direct impact diminishing the dose exposure on both patients and physicians. To solve the referred problems this thesis aims to develop a new hardware/software framework to intuitively and safely guide the surgeon during PRA planning and puncturing. In terms of surgical planning, a set of methodologies were developed to increase the certainty of reaching a specific target inside the kidney. The most relevant abdominal structures for PRA were automatically clustered into different 3D volumes. For that, primitive volumes were merged as a local optimization problem using the minimum description length principle and image statistical properties. A multi-volume Ray Cast method was then used to highlight each segmented volume. Results show that it is possible to detect all abdominal structures surrounding the kidney, with the ability to correctly estimate a virtual trajectory. Concerning the percutaneous puncturing stage, either an electromagnetic or optical solution were developed and tested in multiple in vitro, in vivo and ex vivo trials. The optical tracking solution aids in establishing the desired puncture site and choosing the best virtual puncture trajectory. However, this system required a line of sight to different optical markers placed at the needle base, limiting the accuracy when tracking inside the human body. Results show that the needle tip can deflect from its initial straight line trajectory with an error higher than 3 mm. Moreover, a complex registration procedure and initial setup is needed. On the other hand, a real-time electromagnetic tracking was developed. Hereto, a catheter was inserted trans-urethrally towards the renal target. This catheter has a position and orientation electromagnetic sensor on its tip that function as a real-time target locator. Then, a needle integrating a similar sensor is used. From the data provided by both sensors, one computes a virtual puncture trajectory, which is displayed in a 3D visualization software. In vivo tests showed a median renal and ureteral puncture times of 19 and 51 seconds, respectively (range 14 to 45 and 45 to 67 seconds). Such results represent a puncture time improvement between 75% and 85% when comparing to state of the art methods. 3D sound and vibrotactile feedback were also developed to provide additional information about the needle orientation. By using these kind of feedback, it was verified that the surgeon tends to follow a virtual puncture trajectory with a reduced amount of deviations from the ideal trajectory, being able to anticipate any movement even without looking to a monitor. Best results show that 3D sound sources were correctly identified 79.2 ± 8.1% of times with an average angulation error of 10.4º degrees. Vibration sources were accurately identified 91.1 ± 3.6% of times with an average angulation error of 8.0º degrees. Additionally to the EMT framework, three circular ultrasound transducers were built with a needle working channel. One explored different manufacture fabrication setups in terms of the piezoelectric materials, transducer construction, single vs. multi array configurations, backing and matching material design. The A-scan signals retrieved from each transducer were filtered and processed to automatically detect reflected echoes and to alert the surgeon when undesirable anatomical structures are in between the puncture path. The transducers were mapped in a water tank and tested in a study involving 45 phantoms. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Hereupon, it is expected that the introduction of the proposed system on the PRA procedure, will allow to guide the surgeon through the optimal path towards the precise kidney target, increasing surgeon’s confidence and reducing complications (e.g. organ perforation) during PRA. Moreover, the developed framework has the potential to make the PRA free of radiation for both patient and surgeon and to broad the use of PRA to less specialized surgeons.Intervenções renais minimamente invasivas são realizadas diariamente para o tratamento e diagnóstico de várias doenças renais. O acesso renal percutâneo (ARP) é uma etapa essencial e desafiante na maior parte destes procedimentos. O seu resultado encontra-se diretamente relacionado com a capacidade do cirurgião visualizar e atingir com precisão o alvo anatómico. Hoje em dia, o ARP é sempre guiado com recurso a sistemas imagiológicos, na maior parte das vezes baseados em raios-X (p.e. a fluoroscopia). A radiação destes sistemas nas salas cirúrgicas representa um grande risco para a equipa médica, aonde a sua remoção levará a um impacto direto na diminuição da dose exposta aos pacientes e cirurgiões. De modo a resolver os problemas existentes, esta tese tem como objetivo o desenvolvimento de uma framework de hardware/software que permita, de forma intuitiva e segura, guiar o cirurgião durante o planeamento e punção do ARP. Em termos de planeamento, foi desenvolvido um conjunto de metodologias de modo a aumentar a eficácia com que o alvo anatómico é alcançado. As estruturas abdominais mais relevantes para o procedimento de ARP, foram automaticamente agrupadas em volumes 3D, através de um problema de optimização global com base no princípio de “minimum description length” e propriedades estatísticas da imagem. Por fim, um procedimento de Ray Cast, com múltiplas funções de transferência, foi utilizado para enfatizar as estruturas segmentadas. Os resultados mostram que é possível detetar todas as estruturas abdominais envolventes ao rim, com a capacidade para estimar corretamente uma trajetória virtual. No que diz respeito à fase de punção percutânea, foram testadas duas soluções de deteção de movimento (ótica e eletromagnética) em múltiplos ensaios in vitro, in vivo e ex vivo. A solução baseada em sensores óticos ajudou no cálculo do melhor ponto de punção e na definição da melhor trajetória a seguir. Contudo, este sistema necessita de uma linha de visão com diferentes marcadores óticos acoplados à base da agulha, limitando a precisão com que a agulha é detetada no interior do corpo humano. Os resultados indicam que a agulha pode sofrer deflexões à medida que vai sendo inserida, com erros superiores a 3 mm. Por outro lado, foi desenvolvida e testada uma solução com base em sensores eletromagnéticos. Para tal, um cateter que integra um sensor de posição e orientação na sua ponta, foi colocado por via trans-uretral junto do alvo renal. De seguida, uma agulha, integrando um sensor semelhante, é utilizada para a punção percutânea. A partir da diferença espacial de ambos os sensores, é possível gerar uma trajetória de punção virtual. A mediana do tempo necessário para puncionar o rim e ureter, segundo esta trajetória, foi de 19 e 51 segundos, respetivamente (variações de 14 a 45 e 45 a 67 segundos). Estes resultados representam uma melhoria do tempo de punção entre 75% e 85%, quando comparados com o estado da arte dos métodos atuais. Além do feedback visual, som 3D e feedback vibratório foram explorados de modo a fornecer informações complementares da posição da agulha. Verificou-se que com este tipo de feedback, o cirurgião tende a seguir uma trajetória de punção com desvios mínimos, sendo igualmente capaz de antecipar qualquer movimento, mesmo sem olhar para o monitor. Fontes de som e vibração podem ser corretamente detetadas em 79,2 ± 8,1% e 91,1 ± 3,6%, com erros médios de angulação de 10.4º e 8.0 graus, respetivamente. Adicionalmente ao sistema de navegação, foram também produzidos três transdutores de ultrassom circulares com um canal de trabalho para a agulha. Para tal, foram exploradas diferentes configurações de fabricação em termos de materiais piezoelétricos, transdutores multi-array ou singulares e espessura/material de layers de suporte. Os sinais originados em cada transdutor foram filtrados e processados de modo a detetar de forma automática os ecos refletidos, e assim, alertar o cirurgião quando existem variações anatómicas ao longo do caminho de punção. Os transdutores foram mapeados num tanque de água e testados em 45 phantoms. Os resultados mostraram que o feixe de área em corte transversal oscila em torno do raio de cerâmica, e que os ecos refletidos são detetados em phantoms com comprimentos superiores a 80 mm. Desta forma, é expectável que a introdução deste novo sistema a nível do ARP permitirá conduzir o cirurgião ao longo do caminho de punção ideal, aumentado a confiança do cirurgião e reduzindo possíveis complicações (p.e. a perfuração dos órgãos). Além disso, de realçar que este sistema apresenta o potencial de tornar o ARP livre de radiação e alarga-lo a cirurgiões menos especializados.The present work was only possible thanks to the support by the Portuguese Science and Technology Foundation through the PhD grant with reference SFRH/BD/74276/2010 funded by FCT/MEC (PIDDAC) and by Fundo Europeu de Desenvolvimento Regional (FEDER), Programa COMPETE - Programa Operacional Factores de Competitividade (POFC) do QREN

    Towards parameter-less 3D mesh segmentation

    Full text link
    This thesis focuses on the 3D mesh segmentation process. The research demonstrated how the process can be done in a parameterless approach which allows full automation with accurate results. Applications of this research include, but not limited to, 3D search engines, 3D character animation, robotics environment recognition, and augmented reality

    Red blood cell segmentation and classification method using MATLAB

    Get PDF
    Red blood cells (RBCs) are the most important kind of blood cell. Its diagnosis is very important process for early detection of related disease such as malaria and anemia before suitable follow up treatment can be proceed. Some of the human disease can be showed by counting the number of red blood cells. Red blood cell count gives the vital information that help diagnosis many of the patient’s sickness. Conventional method under blood smears RBC diagnosis is applying light microscope conducted by pathologist. This method is time-consuming and laborious. In this project an automated RBC counting is proposed to speed up the time consumption and to reduce the potential of the wrongly identified RBC. Initially the RBC goes for image pre-processing which involved global thresholding. Then it continues with RBCs counting by using two different algorithms which are the watershed segmentation based on distance transform, and the second one is the artificial neural network (ANN) classification with fitting application depend on regression method. Before applying ANN classification there are step needed to get feature extraction data that are the data extraction using moment invariant. There are still weaknesses and constraints due to the image itself such as color similarity, weak edge boundary, overlapping condition, and image quality. Thus, more study must be done to handle those matters to produce strong analysis approach for medical diagnosis purpose. This project build a better solution and help to improve the current methods so that it can be more capable, robust, and effective whenever any sample of blood cell is analyzed. At the end of this project it conducted comparison between 20 images of blood samples taken from the medical electronic laboratory in Universiti Tun Hussein Onn Malaysia (UTHM). The proposed method has been tested on blood cell images and the effectiveness and reliability of each of the counting method has been demonstrated

    Haptics: Science, Technology, Applications

    Get PDF
    This open access book constitutes the proceedings of the 12th International Conference on Human Haptic Sensing and Touch Enabled Computer Applications, EuroHaptics 2020, held in Leiden, The Netherlands, in September 2020. The 60 papers presented in this volume were carefully reviewed and selected from 111 submissions. The were organized in topical sections on haptic science, haptic technology, and haptic applications. This year's focus is on accessibility
    corecore