255 research outputs found

    The OpenPMU Platform for Open Source Phasor Measurements

    Get PDF

    Software Defined Networks based Smart Grid Communication: A Comprehensive Survey

    Get PDF
    The current power grid is no longer a feasible solution due to ever-increasing user demand of electricity, old infrastructure, and reliability issues and thus require transformation to a better grid a.k.a., smart grid (SG). The key features that distinguish SG from the conventional electrical power grid are its capability to perform two-way communication, demand side management, and real time pricing. Despite all these advantages that SG will bring, there are certain issues which are specific to SG communication system. For instance, network management of current SG systems is complex, time consuming, and done manually. Moreover, SG communication (SGC) system is built on different vendor specific devices and protocols. Therefore, the current SG systems are not protocol independent, thus leading to interoperability issue. Software defined network (SDN) has been proposed to monitor and manage the communication networks globally. This article serves as a comprehensive survey on SDN-based SGC. In this article, we first discuss taxonomy of advantages of SDNbased SGC.We then discuss SDN-based SGC architectures, along with case studies. Our article provides an in-depth discussion on routing schemes for SDN-based SGC. We also provide detailed survey of security and privacy schemes applied to SDN-based SGC. We furthermore present challenges, open issues, and future research directions related to SDN-based SGC.Comment: Accepte

    Centralized Disturbance Detection in Smart Microgrids With Noisy and Intermittent Synchrophasor Data

    Get PDF

    Evaluation of the IEC 61850 Communication Solutions

    Get PDF
    Initially, when the IEC 61850 standard was prepared, it was intended to be used within the limits of a substation for information exchange between devices. In the course of time and due to the standard’s advantages, its concepts are nowadays used as well in other application areas of the power utility system. The IEC 61850 is based to the maximum extent on other existing communication standards (IEC/IEEE/ISO/OSI), offering among others: visualization of the real applications through the ASCI interface, standardized messages to be exchanged (GOOSE, SV), one configuration language regardless of the device (IED) type/brand, and mapping to already implemented computing protocols (MMS, TCP/IP, Ethernet). The features mentioned above lead to cost reduction, reliability, and interoperability, making the IEC61850 the dominant standard for intra- and inter-substation communication. The parts 90-1 and 90-5 of the IEC 61850 standard concern the application of the tunneling and routing method in order to extend the communication beyond the substation’s limits. Although they establish the theoretical background, it can be mentioned a lack of information regarding real applications. So, the objective of this thesis was at first to establish the communication link which will allow the communication of devices belonging to different LANs and second, the acquiring of the round trip times from the exchanged messages. The experiments were conducted by a combination of software (Hamachi) and embedded platform (BeagleBone) pinging to each other first via tunneling and next via 4G mobile network. The acquired round-trip times were used to evaluate and compare the tunneling and the 4G routing method, estimating in parallel what are the perspectives of these methods to be used for inter-substation communication.fi=OpinnĂ€ytetyö kokotekstinĂ€ PDF-muodossa.|en=Thesis fulltext in PDF format.|sv=LĂ€rdomsprov tillgĂ€ngligt som fulltext i PDF-format

    The Use of System in the Loop, Hardware in the Loop, and Co-modeling of Cyber-Physical Systems in Developing and Evaluating New Smart Grid Solutions

    Get PDF
    This paper deals with two issues: development of some advanced smart grid applications, and implementation of advanced testbeds to evaluate these applications. In each of the development cases, the role of the testbeds is explained and evaluation results are presented. The applications cover the synchrophasor systems, interfacing of microgrids to the main grid, and cybersecurity solutions. The paper hypothesizes that the use of the advanced testbeds is beneficial for the development process since the solution product-to-market cycle may be shortened due to early real-life demonstrations. In addition, solution users’ feedback to the testbed demonstration can be incorporated at an early stage when making the changes is not as costly as doing it at more mature development stages

    Synchrophasor Based Islanding & Open phase fault Protection in Distribution Systems

    Get PDF
    With the rapid growth of renewable energy resources, energy efficiency initiatives, electric vehicles, energy storage, etc., distribution systems are becoming more complex such that conventional protection, control, and measurement infrastructure – typically concentrated at the main substation, with little to no access to information along the feeder – cannot maintain the reliability of the system without some sort of additional protection, control and measurement functionalities. As an example, a dedicated communication channel for carrying the transfer trip signal from the substation to the Point of Common Coupling (PCC) to prevent islanding operation of alternative resources, has been a requirement for many utilities. In the transformation of the distribution system from a simple radial system to a bidirectional energy flow network, integration of many intelligent devices and applications will also be required. Thus, this situation calls for investment in communication infrastructure, and augmentation of protection, control, and measurement functionalities. The value of power system communication technologies such as synchrophasor measurement technology – which includes the Phasor Measurement Unit (measuring and providing voltage and current phasors in the real time via communication), communication infrastructure, and Phasor Data Concentrator (PDC) – is being recognized through large-scale deployments around the world. However, these implementations are predominantly limited to some monitoring-type applications and are being realized primarily in transmission systems and bulk power systems (≄100 kV), where performance requirements are much more stringent compared to distribution systems. So contrary to transmission systems, the current status of synchrophasor measurement technology can be utilized to its full extent in distribution systems, as shown in current research for anti-islanding and open-phase faults in the distribution feeder protection application, where the number of PMUs and performance required is somewhat lower than the bulk of power energy. Thus, the opportunity to invest in the implementation of synchronized measurement technology in distribution system is timely as it can be coordinated with other investments in feeder modernization, distributed generation (DG) integration, and infrastructure enhancements that are underway, including “smart grid” initiatives. In the first use case of this research, the behavior of the major DG types during islanding is studied through accurate transient modeling of utility type distribution systems using PSCAD-EMTDC and MATLAB. The study proposes augmentation of PMU-based solutions to the current passive islanding protection elements, such as voltage and frequency, and improving the non-detection zone of the passive elements by adapting their settings based on normal loading conditions at closest known instant prior to the fault or islanding occurrence. The solution proposes a system architecture that requires one PMU at each PCC bus and in the main substation. The communication aspect is based on the IEC 6850-90-5 report, where the PMU can subscribe directly to the data stream of the remote PMUs such that the need for PDCs in this application is eliminated, yielding better performance. In the second use case, an open-phase fault – a major concern for distribution utilities from safety of public and equipment perspective – has been studied. Clearing the open-phase fault without identifying the type of fault could result in an attempt by the recloser to reenergize the downed wire; conversely, an undetected open-phase fault could initiate ferro-resonance, thereby stressing equipment and increasing the risk to public safety, both urban and rural. This work discusses comprehensive analysis of symmetrical components of various types of open-phase faults in the distribution feeder with the presence of distributed generators (DGs) and proposes the use of phasor measurement data located at substation and PCC to identify the open-phase fault. The proposed algorithm relies on the rate of change of the various current and voltage sequence components. In the study conducted, the utility type feeder and substation are modeled in PSCAD-EMTDC, and different types of open-phase fault and shunt faults are studied to verify the dependability and security of proposed algorithm
    • 

    corecore