325 research outputs found

    Temporal Convolution Networks for Real-Time Abdominal Fetal Aorta Analysis with Ultrasound

    Full text link
    The automatic analysis of ultrasound sequences can substantially improve the efficiency of clinical diagnosis. In this work we present our attempt to automate the challenging task of measuring the vascular diameter of the fetal abdominal aorta from ultrasound images. We propose a neural network architecture consisting of three blocks: a convolutional layer for the extraction of imaging features, a Convolution Gated Recurrent Unit (C-GRU) for enforcing the temporal coherence across video frames and exploiting the temporal redundancy of a signal, and a regularized loss function, called \textit{CyclicLoss}, to impose our prior knowledge about the periodicity of the observed signal. We present experimental evidence suggesting that the proposed architecture can reach an accuracy substantially superior to previously proposed methods, providing an average reduction of the mean squared error from 0.31mm20.31 mm^2 (state-of-art) to 0.09mm20.09 mm^2, and a relative error reduction from 8.1%8.1\% to 5.3%5.3\%. The mean execution speed of the proposed approach of 289 frames per second makes it suitable for real time clinical use.Comment: 10 pages, 2 figure

    Real-time diameter of the fetal aorta from ultrasound

    Get PDF
    The automatic analysis of ultrasound sequences can substantially improve the efficiency of clinical diagnosis. This article presents an attempt to automate the challenging task of measuring the vascular diameter of the fetal abdominal aorta from ultrasound images. We propose a neural network architecture consisting of three blocks: a convolutional neural network (CNN) for the extraction of imaging features, a convolution gated recurrent unit (C-GRU) for exploiting the temporal redundancy of the signal, and a regularized loss function, called CyclicLoss, to impose our prior knowledge about the periodicity of the observed signal. The solution is investigated with a cohort of 25 ultrasound sequences acquired during the third-trimester pregnancy check, and with 1000 synthetic sequences. In the extraction of features, it is shown that a shallow CNN outperforms two other deep CNNs with both the real and synthetic cohorts, suggesting that echocardiographic features are optimally captured by a reduced number of CNN layers. The proposed architecture, working with the shallow CNN, reaches an accuracy substantially superior to previously reported methods, providing an average reduction of the mean squared error from 0.31 (state-of-the-art) to 0.09 ackslashmathrmmm2ackslashmathrmmm^2mm2, and a relative error reduction from 8.1 to 5.3%. The mean execution speed of the proposed approach of 289 frames per second makes it suitable for real-time clinical use

    Deep Learning in Cardiology

    Full text link
    The medical field is creating large amount of data that physicians are unable to decipher and use efficiently. Moreover, rule-based expert systems are inefficient in solving complicated medical tasks or for creating insights using big data. Deep learning has emerged as a more accurate and effective technology in a wide range of medical problems such as diagnosis, prediction and intervention. Deep learning is a representation learning method that consists of layers that transform the data non-linearly, thus, revealing hierarchical relationships and structures. In this review we survey deep learning application papers that use structured data, signal and imaging modalities from cardiology. We discuss the advantages and limitations of applying deep learning in cardiology that also apply in medicine in general, while proposing certain directions as the most viable for clinical use.Comment: 27 pages, 2 figures, 10 table

    Real-time diameter of the fetal aorta from ultrasound

    Get PDF
    The automatic analysis of ultrasound sequences can substantially improve the efficiency of clinical diagnosis. This article presents an attempt to automate the challenging task of measuring the vascular diameter of the fetal abdominal aorta from ultrasound images. We propose a neural network architecture consisting of three blocks: a convolutional neural network (CNN) for the extraction of imaging features, a convolution gated recurrent unit (C-GRU) for exploiting the temporal redundancy of the signal, and a regularized loss function, called CyclicLoss, to impose our prior knowledge about the periodicity of the observed signal. The solution is investigated with a cohort of 25 ultrasound sequences acquired during the third-trimester pregnancy check, and with 1000 synthetic sequences. In the extraction of features, it is shown that a shallow CNN outperforms two other deep CNNs with both the real and synthetic cohorts, suggesting that echocardiographic features are optimally captured by a reduced number of CNN layers. The proposed architecture, working with the shallow CNN, reaches an accuracy substantially superior to previously reported methods, providing an average reduction of the mean squared error from 0.31 (state-of-the-art) to 0.09 mm2, and a relative error reduction from 8.1 to 5.3%. The mean execution speed of the proposed approach of 289 frames per second makes it suitable for real-time clinical use

    Temporal Convolution Networks for Real-Time Abdominal Fetal Aorta Analysis with Ultrasound

    Get PDF
    The automatic analysis of ultrasound sequences can substantially improve the efficiency of clinical diagnosis. In this work we present our attempt to automate the challenging task of measuring the vascular diameter of the fetal abdominal aorta from ultrasound images. We propose a neural network architecture consisting of three blocks: a convolutional layer for the extraction of imaging features, a Convolution Gated Recurrent Unit (C-GRU) for enforcing the temporal coherence across video frames and exploiting the temporal redundancy of a signal, and a regularized loss function, called CyclicLoss, to impose our prior knowledge about the periodicity of the observed signal. We present experimental evidence suggesting that the proposed architecture can reach an accuracy substantially superior to previously proposed methods, providing an average reduction of the mean squared error from 0.31mm2 (state-of-art) to 0.09mm2, and a relative error reduction from 8.1% to 5.3%. The mean execution speed of the proposed approach of 289 frames per second makes it suitable for real time clinical use. © Springer Nature Switzerland AG 2018

    Stable automatic envelope estimation for noisy doppler ultrasound

    Get PDF
    Doppler ultrasound technology is widespread in clinical applications and is principally used for blood flow measurements in the heart, arteries and veins. A commonly extracted parameter is the maximum velocity envelope. However, current methods of extracting it cannot produce stable envelopes in high noise conditions. This can limit clinical and research applications using the technology. In this article, a new method of automatic envelope estimation is presented. The method can handle challenging signals with high levels of noise and variable envelope shapes. Envelopes are extracted from a Doppler spectrogram image generated directly from the Doppler audio signal, making it less device-dependent than existing imageprocessing methods. The method’s performance is assessed using simulated pulsatile flow, a flow phantom and in-vivo ascending aortic flow measurements and is compared with three state-of-the-art methods. The proposed method is the most accurate in noisy conditions, achieving on average for phantom data with SNRs below 10 dB, a bias and standard deviation 0.7% and 3.3% lower than the next-best performing method. In addition, a new method for beat segmentation is proposed. When combined, the two proposed methods exhibited the best performance using invivo data, producing the least number of incorrectly segmented beats and 8.2% more correctly segmented beats than the next best performing method. The ability of the proposed methods to reliably extract timing indices for cardiac cycles across a range of signal quality is of particular significance for research and monitoring applications

    Using averaged models from 4D ultrasound strain imaging allows to signifcantly diferentiate local wall strains in calcifed regions of abdominal aortic aneurysms

    Get PDF
    Abdominal aortic aneurysms are a degenerative disease of the aorta associated with high mortality. To date, in vivo information to characterize the individual elastic properties of the aneurysm wall in terms of rupture risk is lacking. We have used time-resolved 3D ultrasound strain imaging to calculate spatially resolved in-plane strain distributions characterized by mean and local maximum strains, as well as indices of local variations in strains. Likewise, we here present a method to generate averaged models from multiple segmentations. Strains were then calculated for single segmentations and averaged models. After registration with aneurysm geometries based on CT-A imaging, local strains were divided into two groups with and without calcifications and compared. Geometry comparison from both imaging modalities showed good agreement with a root mean squared error of 1.22 ± 0.15 mm and Hausdorff Distance of 5.45 ± 1.56 mm (mean ± sd, respectively). Using averaged models, circumferential strains in areas with calcifications were 23.2 ± 11.7% (mean ± sd) smaller and significantly distinguishable at the 5% level from areas without calcifications. For single segmentations, this was possible only in 50% of cases. The areas without calcifications showed greater heterogeneity, larger maximum strains, and smaller strain ratios when computed by use of the averaged models. Using these averaged models, reliable conclusions can be made about the local elastic properties of individual aneurysm (and long-term observations of their change), rather than just group comparisons. This is an important prerequisite for clinical application and provides qualitatively new information about the change of an abdominal aortic aneurysm in the course of disease progression compared to the diameter criterion
    • …