3,807 research outputs found

    Full waveform analysis for long-range 3D imaging laser radar

    Get PDF
    The new generation of 3D imaging systems based on laser radar (ladar) offers significant advantages in defense and security applications. In particular, it is possible to retrieve 3D shape information directly from the scene and separate a target from background or foreground clutter by extracting a narrow depth range from the field of view by range gating, either in the sensor or by postprocessing. We discuss and demonstrate the applicability of full-waveform ladar to produce multilayer 3D imagery, in which each pixel produces a complex temporal response that describes the scene structure. Such complexity caused by multiple and distributed reflection arises in many relevant scenarios, for example in viewing partially occluded targets, through semitransparent materials (e.g., windows) and through distributed reflective media such as foliage. We demonstrate our methodology on 3D image data acquired by a scanning time-of-flight system, developed in our own laboratories, which uses the time-correlated single-photon counting technique

    Improved linearity using harmonic error rejection in a full-field range imaging system

    Get PDF
    Full field range imaging cameras are used to simultaneously measure the distance for every pixel in a given scene using an intensity modulated illumination source and a gain modulated receiver array. The light is reflected from an object in the scene, and the modulation envelope experiences a phase shift proportional to the target distance. Ideally the waveforms are sinusoidal, allowing the phase, and hence object range, to be determined from four measurements using an arctangent function. In practice these waveforms are often not perfectly sinusoidal, and in some cases square waveforms are instead used to simplify the electronic drive requirements. The waveforms therefore commonly contain odd harmonics which contribute a nonlinear error to the phase determination, and therefore an error in the range measurement. We have developed a unique sampling method to cancel the effect of these harmonics, with the results showing an order of magnitude improvement in the measurement linearity without the need for calibration or lookup tables, while the acquisition time remains unchanged. The technique can be applied to existing range imaging systems without having to change or modify the complex illumination or sensor systems, instead only requiring a change to the signal generation and timing electronics

    Multiple return separation for a full-field ranger via continuous waveform modelling

    Get PDF
    We present two novel Poisson noise Maximum Likelihood based methods for identifying the individual returns within mixed pixels for Amplitude Modulated Continuous Wave rangers. These methods use the convolutional relationship between signal returns and the recorded data to determine the number, range and intensity of returns within a pixel. One method relies on a continuous piecewise truncated-triangle model for the beat waveform and the other on linear interpolation between translated versions of a sampled waveform. In the single return case both methods provide an improvement in ranging precision over standard Fourier transform based methods and a decrease in overall error in almost every case. We find that it is possible to discriminate between two light sources within a pixel, but local minima and scattered light have a significant impact on ranging precision. Discrimination of two returns requires the ability to take samples at less than 90 phase shifts

    Frequency-modulated continuous-wave LiDAR compressive depth-mapping

    Get PDF
    We present an inexpensive architecture for converting a frequency-modulated continuous-wave LiDAR system into a compressive-sensing based depth-mapping camera. Instead of raster scanning to obtain depth-maps, compressive sensing is used to significantly reduce the number of measurements. Ideally, our approach requires two difference detectors. % but can operate with only one at the cost of doubling the number of measurments. Due to the large flux entering the detectors, the signal amplification from heterodyne detection, and the effects of background subtraction from compressive sensing, the system can obtain higher signal-to-noise ratios over detector-array based schemes while scanning a scene faster than is possible through raster-scanning. %Moreover, we show how a single total-variation minimization and two fast least-squares minimizations, instead of a single complex nonlinear minimization, can efficiently recover high-resolution depth-maps with minimal computational overhead. Moreover, by efficiently storing only 2m2m data points from m<nm<n measurements of an nn pixel scene, we can easily extract depths by solving only two linear equations with efficient convex-optimization methods

    Full waveform LiDAR for adverse weather conditions

    Get PDF

    Lidar waveform based analysis of depth images constructed using sparse single-photon data

    Get PDF
    This paper presents a new Bayesian model and algorithm used for depth and intensity profiling using full waveforms from the time-correlated single photon counting (TCSPC) measurement in the limit of very low photon counts. The model proposed represents each Lidar waveform as a combination of a known impulse response, weighted by the target intensity, and an unknown constant background, corrupted by Poisson noise. Prior knowledge about the problem is embedded in a hierarchical model that describes the dependence structure between the model parameters and their constraints. In particular, a gamma Markov random field (MRF) is used to model the joint distribution of the target intensity, and a second MRF is used to model the distribution of the target depth, which are both expected to exhibit significant spatial correlations. An adaptive Markov chain Monte Carlo algorithm is then proposed to compute the Bayesian estimates of interest and perform Bayesian inference. This algorithm is equipped with a stochastic optimization adaptation mechanism that automatically adjusts the parameters of the MRFs by maximum marginal likelihood estimation. Finally, the benefits of the proposed methodology are demonstrated through a serie of experiments using real data

    Computational multi-depth single-photon imaging

    Full text link
    We present an imaging framework that is able to accurately reconstruct multiple depths at individual pixels from single-photon observations. Our active imaging method models the single-photon detection statistics from multiple reflectors within a pixel, and it also exploits the fact that a multi-depth profile at each pixel can be expressed as a sparse signal. We interpret the multi-depth reconstruction problem as a sparse deconvolution problem using single-photon observations, create a convex problem through discretization and relaxation, and use a modified iterative shrinkage-thresholding algorithm to efficiently solve for the optimal multi-depth solution. We experimentally demonstrate that the proposed framework is able to accurately reconstruct the depth features of an object that is behind a partially-reflecting scatterer and 4 m away from the imager with root mean-square error of 11 cm, using only 19 signal photon detections per pixel in the presence of moderate background light. In terms of root mean-square error, this is a factor of 4.2 improvement over the conventional method of Gaussian-mixture fitting for multi-depth recovery.This material is based upon work supported in part by a Samsung Scholarship, the US National Science Foundation under Grant No. 1422034, and the MIT Lincoln Laboratory Advanced Concepts Committee. We thank Dheera Venkatraman for his assistance with the experiments. (Samsung Scholarship; 1422034 - US National Science Foundation; MIT Lincoln Laboratory Advanced Concepts Committee)Accepted manuscrip

    Video-rate or high-precision: A flexible range imaging camera

    Get PDF
    A range imaging camera produces an output similar to a digital photograph, but every pixel in the image contains distance information as well as intensity. This is useful for measuring the shape, size and location of objects in a scene, hence is well suited to certain machine vision applications. Previously we demonstrated a heterodyne range imaging system operating in a relatively high resolution (512-by-512) pixels and high precision (0.4 mm best case) configuration, but with a slow measurement rate (one every 10 s). Although this high precision range imaging is useful for some applications, the low acquisition speed is limiting in many situations. The system’s frame rate and length of acquisition is fully configurable in software, which means the measurement rate can be increased by compromising precision and image resolution. In this paper we demonstrate the flexibility of our range imaging system by showing examples of high precision ranging at slow acquisition speeds and video-rate ranging with reduced ranging precision and image resolution. We also show that the heterodyne approach and the use of more than four samples per beat cycle provides better linearity than the traditional homodyne quadrature detection approach. Finally, we comment on practical issues of frame rate and beat signal frequency selection

    Persepsi pelajar sarjana muda kejuruteraan elektrik terhadap program latihan industri, Kolej Universiti Teknologi Tun Hussein Onn

    Get PDF
    Kajian ini dijalankan bertujuan untuk mengetahui persepsi Pelajar Sarjana Muda Kejuruteraan Elektrik Terhadap Program Latihan Industri, KUiTTHO berdasarkan kepada 4 faktor iaitu kesesuaian penempatan program latihan industri, kesesuaian pendedahan pelajaran teori di KUiTTHO dan amali di tempat program latihan industri, tahap kerjasama yang diberikan oleh pihak industri kepada pelajar d a n kesediaan pelajar melakukan kerja yang diberi semasa program latihan industri. Sampel kajian adalah terdiri daripada pelajar-pelajar Sarjana Mud a Kejuruteraan Elektrik di KUITTHO yang telah menjalani program latihan industri. Set soal selidik terdiri daripada 3 bahagian iaitu bahagian A yang bertujuan untuk mendapatkan maklumat diri responden manakala bahagian Bertujuan untuk mengetahui kesesuaian program latihan industri yang telah diikuti oleh pelajar dan bahagian C adalah cadangan untuk meningkatkan mutu program latihan industri. Data - data yang diperolehi dianalisis menggunakan perisisan SPSS 10.0 for Windows (Statistical Package for the Social Science version 10) dan dipersembahkan dalam bentuk peratusan, carta dan keterangan analisis. Dapatan kajian secara umumnya menunjukkan reaksi positif dimana bagi semua aspek menunjukkan min keseluruhan yang tingg
    corecore