4,906 research outputs found

    Thermal dosimetry for bladder hyperthermia treatment. An overview.

    Get PDF
    The urinary bladder is a fluid-filled organ. This makes, on the one hand, the internal surface of the bladder wall relatively easy to heat and ensures in most cases a relatively homogeneous temperature distribution; on the other hand the variable volume, organ motion, and moving fluid cause artefacts for most non-invasive thermometry methods, and require additional efforts in planning accurate thermal treatment of bladder cancer. We give an overview of the thermometry methods currently used and investigated for hyperthermia treatments of bladder cancer, and discuss their advantages and disadvantages within the context of the specific disease (muscle-invasive or non-muscle-invasive bladder cancer) and the heating technique used. The role of treatment simulation to determine the thermal dose delivered is also discussed. Generally speaking, invasive measurement methods are more accurate than non-invasive methods, but provide more limited spatial information; therefore, a combination of both is desirable, preferably supplemented by simulations. Current efforts at research and clinical centres continue to improve non-invasive thermometry methods and the reliability of treatment planning and control software. Due to the challenges in measuring temperature across the non-stationary bladder wall and surrounding tissues, more research is needed to increase our knowledge about the penetration depth and typical heating pattern of the various hyperthermia devices, in order to further improve treatments. The ability to better determine the delivered thermal dose will enable clinicians to investigate the optimal treatment parameters, and consequentially, to give better controlled, thus even more reliable and effective, thermal treatments

    Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla

    Get PDF
    This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0>/=7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B0 = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B0 which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (DeltaT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19x23x32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device

    Mathematical methods for magnetic resonance based electric properties tomography

    Get PDF
    Magnetic resonance-based electric properties tomography (MREPT) is a recent quantitative imaging technique that could provide useful additional information to the results of magnetic resonance imaging (MRI) examinations. Precisely, MREPT is a collective name that gathers all the techniques that elaborate the radiofrequency (RF) magnetic field B1 generated and measured by a MRI scanner in order to map the electric properties inside a human body. The range of uses of MREPT in clinical oncology, patient-specific treatment planning and MRI safety motivates the increasing scientific interest in its development. The main advantage of MREPT with respect to other techniques for electric properties imaging is the knowledge of the input field inside the examined body, which guarantees the possibility of achieving high-resolution. On the other hand, MREPT techniques rely on just the incomplete information that MRI scanners can measure of the RF magnetic field, typically limited to the transmit sensitivity B1+. In this thesis, the state of art is described in detail by analysing the whole bibliography of MREPT, started few years ago but already rich of contents. With reference to the advantages and drawbacks of each technique proposed for MREPT, the particular implementation based on the contrast source inversion method is selected as the most promising approach for MRI safety applications and is denoted by the symbol csiEPT. Motivated by this observation, a substantial part of the thesis is devoted to a thoroughly study of csiEPT. Precisely, a generalised framework based on a functional point of view is proposed for its implementation. In this way, it is possible to adapt csiEPT to various physical situations. In particular, an original formulation, specifically developed to take into account the effects of the conductive shield always employed in RF coils, shows how an accurate modelling of the measurement system leads to more precise estimations of the electric properties. In addition, a preliminary study for the uncertainty assessment of csiEPT, an imperative requirement in order to make the method reliable for in vivo applications, is performed. The uncertainty propagation through csiEPT is studied using the Monte Carlo method as prescribed by the Supplement 1 to GUM (Guide to the expression of Uncertainty in Measurement). The robustness of the method when measurements are performed by multi-channel TEM coils for parallel transmission confirms the eligibility of csiEPT for MRI safety applications

    LC Sensor for biological tissue characterization

    Get PDF
    Over the past few decades, there has been growing interest and increased research on bio-implantable devices using RF telemetry links, enabling the continuous monitoring and recording of physiological data. However the dispersive properties of tissues make this a formidable task. In the present work, a novel technique for tissue characterization using an LC sensor is developed which allows for the extraction of the relative permittivity, and the conductivity of dispersive tissues. The resonant frequency of the sensor is monitored by measuring the input impedance of an external antenna, and correlated to the desired quantities. The impact of multi-layered dispersive tissues on the setup of the telemetry link is demonstrated where the role of the capacitor is analyzed. The sensor consists of a planar inductor, and an interdigital capacitor. Using an equivalent circuit model of the sensor that accounts for the properties of the encapsulating tissue, analytical expressions have been developed for the extraction of the tissue permittivity and conductivity. In addition, the effect of the thicknesses of the tissue layers on the sensor resonant frequency is studied. It is seen that the resonant frequency is strongly affected by the properties of the first layer, whereas additional layers prove to have little to no effect. A saturation thickness is defined that allows for the sensor to be implanted at a depth where it is only affected by the properties of the layer in which it is embedded. In order to analyze the telemetry system, a single loop antenna is evaluated in proximity to the biological tissue layer and the interaction of the electromagnetic field with the body is assessed in terms of specific absorption rate (SAR). It is studied through different multi-layered models composed of skin, fat and muscle, with typical values of tissue thickness. The introduction of multiple tissue layers as well as the misalignment effect is investigated from the SAR distribution. Finally, experimental validation has been performed with a telemetry link that consists of a loop antenna and a fabricated LC sensor immersed in single and multiple dispersive regions

    Development Of An Accurate Benchmarking System For Microwave Breast Imaging

    Get PDF
    This thesis is a discussion of the design and implementation of benchmarking system for microwave imaging systems. The current benchmarking tools for microwave imaging setups are not adaptable. A novel method for of the development of a dielectric phantom using regression analysis is presented. This is followed by a discussion of the design of a novel sensor for the purpose of in vivo dielectric properties measurements. The goal is to provide information for microwave tomography algorithms and phantom development based on in vivo dielectric properties of breast tissues Through the progress of this research two major novel advances have been made toward producing a better microwave imaging benchmark. First, a technique for systematically developing a breast phantom using regression analysis has been developed. This defines a process for researchers to produce a phantom quickly and easily, avoiding the simple trial and error development techniques of the past. Secondly, a method for measuring dielectric constant of a material through an embedded sensor was developed. Both advances are very important in producing accurate phantoms, providing in vivo tissue properties for tomography algorithms and designing matching materials for microwave imaging

    Imaging of the Breast

    Get PDF
    Early detection of breast cancer combined with targeted therapy offers the best outcome for breast cancer patients. This volume deal with a wide range of new technical innovations for improving breast cancer detection, diagnosis and therapy. There is a special focus on improvements in mammographic image quality, image analysis, magnetic resonance imaging of the breast and molecular imaging. A chapter on targeted therapy explores the option of less radical postoperative therapy for women with early, screen-detected breast cancers

    Inverse Problems in Wave Scattering and Impedance Tomography

    Get PDF
    [no abstract available

    Three-Dimensional Impedance Tomographic Mapping of Metabolically Active Endolumen

    Get PDF
    Real-time detection of vulnerable atherosclerotic lesions, characterized by a high content of oxidized low-density lipoprotein (oxLDL)-laden macrophages or foam cells, remains an unmet clinical need. While fractional flow reserve (FFR)-guided revascularization in angiographically intermediate stenoses is utilized to assess hemodynamic significance, in vivo detection of oxLDL-rich plaques may provide a new paradigm for treating metabolically unstable lesions. Herein, we have demonstrated endoluminal mapping of lipid-laden lesions using 3-D electrical impedance spectroscopy-derived impedance tomography (EIT) in a pre-clinical swine model. We performed surgical banding of the right carotid arteries of Yucatan mini-pigs, followed by 16 weeks of high-fat diet, to promote the development of lipid-rich lesions. We implemented an intravascular sensor combining an FFR pressure transducer with a 6-point micro-electrode array for electrical impedance spectroscopy (EIS) measurements. 3-D EIT mapping was achieved using an EIS-based reconstruction algorithm. We demonstrated that EIT mapping corresponds to endoluminal histology for oxLDL-laden lesions. We further used computational models to theoretically predict and validate EIS measurements. Thus, our 3-D EIS-derived EIT provides in vivo detection of metabolically active plaques with the goal of guiding optimal intravascular intervention

    Combined brain language connectivity and intraoperative neurophysiologic techniques in awake craniotomy for eloquent-area brain tumor resection

    Get PDF
    Speech processing can be disturbed by primary brain tumors (PBT). Improvement of presurgical planning techniques decrease neurological morbidity associated to tumor resection during awake craniotomy. The aims of this work were: 1. To perform Diffusion Kurtosis Imaging based tractography (DKI-tract) in the detection of brain tracts involved in language; 2. To investigate which factors contribute to functional magnetic resonance imaging (fMRI) maps in predicting eloquent language regional reorganization; 3. To determine the technical aspects of accelerometric (ACC) recording of speech during surgery. DKI-tracts were streamlined using a 1.5T magnetic resonance scanner. Number of tracts and fiber pathways were compared between DKI and standard Diffusion Tensor Imaging (DTI) in healthy subjects (HS) and PBT patients. fMRI data were acquired using task-specific and resting-state paradigms during language and motor tasks. After testing intraoperative fMRI’s influence on direct cortical stimulation (DCS) number of stimuli, graph-theory measures were extracted and analyzed. Regarding speech recording, ACC signals were recorded after evaluating neck positions and filter bandwidths. To test this method, language disturbances were recorded in patients with dysphonia and after applying DCS in the inferior frontal gyrus. In contrast, HS reaction time was recorded during speech execution. DKI-tract showed increased number of arcuate fascicle tracts in PBT patients. Lower spurious tracts were identified with DKI-tract. Intraoperative fMRI and DCS showed similar stimuli in comparison with DCS alone. Increased local centrality accompanied language ipsilateral and contralateral reorganization. ACC recordings showed minor artifact contamination when placed at the suprasternal notch using a 20-200 Hz filter bandwidth. Patients with dysphonia showed decreased amplitude and frequency in comparison with HS. ACC detected an additional 11% disturbances after DCS, and a shortening of latency within the presence of a loud stimuli during speech execution. This work improved current knowledge on presurgical planning techniques based on brain structural and functional neuroimaging connectivity, and speech recordingA função linguística do ser humano pode ser afetada pela presença de tumores cerebrais (TC) A melhoria de técnicas de planeamento pré-cirurgico diminui a morbilidade neurológica iatrogénica associada ao seu tratamento cirúrgico. O objetivo deste trabalho é: 1. Testar a fiabilidade da tractografia estimada por difusor de kurtose (tract-DKI), dos feixes cerebrais envolvidos na linguagem 2. Identificar os fatores que contribuem para o mapeamento linguagem por ressonância magnética funcional (RMf) na predição da neuroplasticidade. 3. Identificar aspetos técnicos do registo da linguagem por accelerometria (ACC). A DKI-tract foi estimada após realização de RM cerebral com 1.5T. O número e percurso das fibras foi avaliado. A RMf foi adquirida durante realização de tarefas linguísticas, motoras, e em repouso. Foi testada influência dos mapas de ativação calculados por RMf, no número de estímulos realizados durante a estimulação direta cortical (EDC) intraoperatória. Medidas de conectividade foram extraídas de regiões cerebrais. A posição e filtragem de sinal ACC foram estudadas após vocalização de palavras. O sinal ACC obtido em voluntários foi comparado com doentes disfónicos, após estimulação do giro inferior frontal, e após a adição de um estímulo sonoro perturbador durante vocalização. A tract-DKI estimou um elevado número de fascículos do feixe arcuato com menos falsos negativos. Os mapas linguísticos de RMf intraoperatória, não influenciou a EDC. Medidas de centralidade aumentaram após neuroplasticidade ipsilateral e contralateral. A posição supraesternal e a filtragem de sinal ACC entre 20-200Hz demonstrou menor ruido de contaminação. Este método identificou diminuição de frequência e amplitude em doentes com disfonia, 11% de erros linguísticos adicionais após estimulação e diminuição do tempo de latência quando presente o sinal sonoro perturbador. Este trabalho promoveu a utilização de novas técnicas no planeamento pré-cirúrgico do doente com tumor cerebral e alterações da linguagem através do estudo de conectividade estrutural, funcional e registo da linguagem

    Brain and Human Body Modeling

    Get PDF
    This open access book describes modern applications of computational human modeling with specific emphasis in the areas of neurology and neuroelectromagnetics, depression and cancer treatments, radio-frequency studies and wireless communications. Special consideration is also given to the use of human modeling to the computational assessment of relevant regulatory and safety requirements. Readers working on applications that may expose human subjects to electromagnetic radiation will benefit from this book’s coverage of the latest developments in computational modelling and human phantom development to assess a given technology’s safety and efficacy in a timely manner. Describes construction and application of computational human models including anatomically detailed and subject specific models; Explains new practices in computational human modeling for neuroelectromagnetics, electromagnetic safety, and exposure evaluations; Includes a survey of modern applications for which computational human models are critical; Describes cellular-level interactions between the human body and electromagnetic fields
    • …
    corecore