11 research outputs found

    Registration accuracy of the optical navigation system for image-guided surgery

    Get PDF
    Abstract. During the last decades, image-guided surgery has been a vastly growing method during medical operations. It provides a new opportunity to perform surgical operations with higher accuracy and reliability than before. In image-guided surgery, a navigation system is used to track the instrument’s location and orientation during the surgery. These navigation systems can track the instrument in many ways, the most common of which are optical tracking, mechanical tracking, and electromagnetic tracking. Usually, the navigation systems are used primarily in surgical operations located in the head and spine area. For this reason, it is essential to know the registration accuracy and thus the navigational accuracy of the navigation system, and how different registration methods might affect them. In this research, the registration accuracy of the optical navigation system is investigated by using a head phantom whose coordinate values of holes in the surface are measured during the navigation after different registration scenarios. Reference points are determined using computed tomography images taken from the head phantom. The absolute differences of the measured points to the corresponding reference points are calculated and the results are illustrated using bar graphs and three-dimensional point clouds. MATLAB is used to analyze and present the results. Results show that registration accuracy and thus also navigation accuracy are primarily affected by how the first three registration points are determined for the navigation system at the beginning of the registration. This should be considered in future applications where the navigation system is used in image-guided surgery.Kuvaohjatun kirurgian optisen navigointilaitteen rekisteröintitarkkuus. Tiivistelmä. Viimeisten vuosikymmenien aikana kuvaohjattu kirurgia on yleistynyt laajalti lääketieteellisten toimenpiteiden aikana ja se tarjoaa entistä paremman mahdollisuuden tarkkaan ja luotettavaan hoitoon. Kuvaohjatussa kirurgiassa navigointilaitteisto seuraa käytetyn instrumentin paikkaa ja orientaatiota operaation aikana. Navigointilaitteistoilla on erilaisia toimintaperiaatteita, joiden perusteella ne seuraavat instrumenttia. Yleisimmin käytetyt navigointilaitteistot perustuvat optiseen, mekaaniseen, tai sähkömagneettiseen seurantaan. Yleensä kuvaohjattua kirurgiaa käytetään pään ja selkärangan alueen kirurgisissa operaatioissa, joten on erittäin tärkeää, että navigointilaitteiston rekisteröinti- ja siten myös navigointitarkkuus tunnetaan, sekä erilaisten rekisteröintitapojen mahdolliset vaikutukset kyseisiin tarkkuuksiin. Tässä tutkimuksessa optisen navigointilaitteen rekisteröintitarkkuutta tutkitaan päämallin avulla, jonka pintaan luotujen reikien koordinaattiarvot mitataan navigointitilanteessa erilaisten rekisteröintitapojen jälkeen. Referenssipisteet kyseisille mittauspisteille määritetään päämallin tietokonetomografiakuvista. Mitattujen pisteiden, sekä vastaavien referenssipisteiden väliset absoluuttiset erot lasketaan ja tulokset esitetään palkkikuvaajien, sekä kolmiulotteisten pistepilvien avulla käyttäen apuna MATLAB-ohjelmistoa. Tulokset osoittavat, että rekisteröintitarkkuuteen ja siten navigointitarkkuuteen vaikuttaa eniten rekisteröintitilanteen alussa määritettävien kolmen ensimmäisen rekisteröintipisteen sijainti ja tämä tuleekin ottaa huomioon jatkossa tilanteissa, joissa navigointilaitetta käytetään kuvaohjatussa kirurgiassa

    Interfaces for Modular Surgical Planning and Assistance Systems

    Get PDF
    Modern surgery of the 21st century relies in many aspects on computers or, in a wider sense, digital data processing. Department administration, OR scheduling, billing, and - with increasing pervasion - patient data management are performed with the aid of so called Surgical Information Systems (SIS) or, more general, Hospital Information Systems (HIS). Computer Assisted Surgery (CAS) summarizes techniques which assist a surgeon in the preparation and conduction of surgical interventions. Today still predominantly based on radiology images, these techniques include the preoperative determination of an optimal surgical strategy and intraoperative systems which aim at increasing the accuracy of surgical manipulations. CAS is a relatively young field of computer science. One of the unsolved "teething troubles" of CAS is the absence of technical standards for the interconnectivity of CAS system. Current CAS systems are usually "islands of information" with no connection to other devices within the operating room or hospital-wide information systems. Several workshop reports and individual publications point out that this situation leads to ergonomic, logistic, and economic limitations in hospital work. Perioperative processes are prolonged by the manual installation and configuration of an increasing amount of technical devices. Intraoperatively, a large amount of the surgeons'' attention is absorbed by the requirement to monitor and operate systems. The need for open infrastructures which enable the integration of CAS devices from different vendors in order to exchange information as well as commands among these devices through a network has been identified by numerous experts with backgrounds in medicine as well as engineering. This thesis contains two approaches to the integration of CAS systems: - For perioperative data exchange, the specification of new data structures as an amendment to the existing DICOM standard for radiology image management is presented. The extension of DICOM towards surgical application allows for the seamless integration of surgical planning and reporting systems into DICOM-based Picture Archiving and Communication Systems (PACS) as they are installed in most hospitals for the exchange and long-term archival of patient images and image-related patient data. - For the integration of intraoperatively used CAS devices, such as, e.g., navigation systems, video image sources, or biosensors, the concept of a surgical middleware is presented. A c++ class library, the TiCoLi, is presented which facilitates the configuration of ad-hoc networks among the modules of a distributed CAS system as well as the exchange of data streams, singular data objects, and commands between these modules. The TiCoLi is the first software library for a surgical field of application to implement all of these services. To demonstrate the suitability of the presented specifications and their implementation, two modular CAS applications are presented which utilize the proposed DICOM extensions for perioperative exchange of surgical planning data as well as the TiCoLi for establishing an intraoperative network of autonomous, yet not independent, CAS modules.Die moderne Hochleistungschirurgie des 21. Jahrhunderts ist auf vielerlei Weise abhängig von Computern oder, im weiteren Sinne, der digitalen Datenverarbeitung. Administrative Abläufe, wie die Erstellung von Nutzungsplänen für die verfügbaren technischen, räumlichen und personellen Ressourcen, die Rechnungsstellung und - in zunehmendem Maße - die Verwaltung und Archivierung von Patientendaten werden mit Hilfe von digitalen Informationssystemen rationell und effizient durchgeführt. Innerhalb der Krankenhausinformationssysteme (KIS, oder englisch HIS) stehen für die speziellen Bedürfnisse der einzelnen Fachabteilungen oft spezifische Informationssysteme zur Verfügung. Chirurgieinformationssysteme (CIS, oder englisch SIS) decken hierbei vor allen Dingen die Bereiche Operationsplanung sowie Materialwirtschaft für spezifisch chirurgische Verbrauchsmaterialien ab. Während die genannten HIS und SIS vornehmlich der Optimierung administrativer Aufgaben dienen, stehen die Systeme der Computerassistierten Chirugie (CAS) wesentlich direkter im Dienste der eigentlichen chirugischen Behandlungsplanung und Therapie. Die CAS verwendet Methoden der Robotik, digitalen Bild- und Signalverarbeitung, künstlichen Intelligenz, numerischen Simulation, um nur einige zu nennen, zur patientenspezifischen Behandlungsplanung und zur intraoperativen Unterstützung des OP-Teams, allen voran des Chirurgen. Vor allen Dingen Fortschritte in der räumlichen Verfolgung von Werkzeugen und Patienten ("Tracking"), die Verfügbarkeit dreidimensionaler radiologischer Aufnahmen (CT, MRT, ...) und der Einsatz verschiedener Robotersysteme haben in den vergangenen Jahrzehnten den Einzug des Computers in den Operationssaal - medienwirksam - ermöglicht. Weniger prominent, jedoch keinesfalls von untergeordnetem praktischen Nutzen, sind Beispiele zur automatisierten Überwachung klinischer Messwerte, wie etwa Blutdruck oder Sauerstoffsättigung. Im Gegensatz zu den meist hochgradig verteilten und gut miteinander verwobenen Informationssystemen für die Krankenhausadministration und Patientendatenverwaltung, sind die Systeme der CAS heutzutage meist wenig oder überhaupt nicht miteinander und mit Hintergrundsdatenspeichern vernetzt. Eine Reihe wissenschaftlicher Publikationen und interdisziplinärer Workshops hat sich in den vergangen ein bis zwei Jahrzehnten mit den Problemen des Alltagseinsatzes von CAS Systemen befasst. Mit steigender Intensität wurde hierbei auf den Mangel an infrastrukturiellen Grundlagen für die Vernetzung intraoperativ eingesetzter CAS Systeme miteinander und mit den perioperativ eingesetzten Planungs-, Dokumentations- und Archivierungssystemen hingewiesen. Die sich daraus ergebenden negativen Einflüsse auf die Effizienz perioperativer Abläufe - jedes Gerät muss manuell in Betrieb genommen und mit den spezifischen Daten des nächsten Patienten gefüttert werden - sowie die zunehmende Aufmerksamkeit, welche der Operateur und sein Team auf die Überwachung und dem Betrieb der einzelnen Geräte verwenden muss, werden als eine der "Kinderkrankheiten" dieser relativ jungen Technologie betrachtet und stehen einer Verbreitung über die Grenzen einer engagierten technophilen Nutzergruppe hinaus im Wege. Die vorliegende Arbeit zeigt zwei parallel von einander (jedoch, im Sinne der Schnittstellenkompatibilität, nicht gänzlich unabhängig voneinander) zu betreibende Ansätze zur Integration von CAS Systemen. - Für den perioperativen Datenaustausch wird die Spezifikation zusätzlicher Datenstrukturen zum Transfer chirurgischer Planungsdaten im Rahmen des in radiologischen Bildverarbeitungssystemen weit verbreiteten DICOM Standards vorgeschlagen und an zwei Beispielen vorgeführt. Die Erweiterung des DICOM Standards für den perioperativen Einsatz ermöglicht hierbei die nahtlose Integration chirurgischer Planungssysteme in existierende "Picture Archiving and Communication Systems" (PACS), welche in den meisten Fällen auf dem DICOM Standard basieren oder zumindest damit kompatibel sind. Dadurch ist einerseits der Tatsache Rechnung getragen, dass die patientenspezifische OP-Planung in hohem Masse auf radiologischen Bildern basiert und andererseits sicher gestellt, dass die Planungsergebnisse entsprechend der geltenden Bestimmungen langfristig archiviert und gegen unbefugten Zugriff geschützt sind - PACS Server liefern hier bereits wohlerprobte Lösungen. - Für die integration intraoperativer CAS Systeme, wie etwa Navigationssysteme, Videobildquellen oder Sensoren zur Überwachung der Vitalparameter, wird das Konzept einer "chirurgischen Middleware" vorgestellt. Unter dem Namen TiCoLi wurde eine c++ Klassenbibliothek entwickelt, auf deren Grundlage die Konfiguration von ad-hoc Netzwerken während der OP-Vorbereitung mittels plug-and-play Mechanismen erleichtert wird. Nach erfolgter Konfiguration ermöglicht die TiCoLi den Austausch kontinuierlicher Datenströme sowie einzelner Datenpakete und Kommandos zwischen den Modulen einer verteilten CAS Anwendung durch ein Ethernet-basiertes Netzwerk. Die TiCoLi ist die erste frei verfügbare Klassenbibliothek welche diese Funktionalitäten dediziert für einen Einsatz im chirurgischen Umfeld vereinigt. Zum Nachweis der Tauglichkeit der gezeigten Spezifikationen und deren Implementierungen, werden zwei modulare CAS Anwendungen präsentiert, welche die vorgeschlagenen DICOM Erweiterungen zum perioperativen Austausch von Planungsergebnissen sowie die TiCoLi zum intraoperativen Datenaustausch von Messdaten unter echzeitnahen Anforderungen verwenden

    Intraoperative Endoscopic Augmented Reality in Third Ventriculostomy

    Get PDF
    In neurosurgery, as a result of the brain-shift, the preoperative patient models used as a intraoperative reference change. A meaningful use of the preoperative virtual models during the operation requires for a model update. The NEAR project, Neuroendoscopy towards Augmented Reality, describes a new camera calibration model for high distorted lenses and introduces the concept of active endoscopes endowed with with navigation, camera calibration, augmented reality and triangulation modules

    Factors affecting accuracy and fusion rate in lumbosacral fusion surgery - a preclinical and clinical study

    Get PDF
    Lumbosacral fusion surgery is indicated in symptomatic degenerative lumbosacral disorder, when the origin of pain is demonstrated to lie within the restricted number of functional spinal units and when the pain is refractory to the conservative treatment, to eliminate painful motion of the spinal units. Inaccurate placement of pedicle screws may cause neurological symptoms, and result in early hardware failure and return of spinal instability symptoms. All spinal instrumentation eventually fails without solid bony fusion, and the presence of symptomatic bony non-union at least a year after fusion surgery is defined as pseudoarthrosis. Bioactive glasses (BAGs) are synthetic, biocompatible, osteoconductive and osteostimulative materials with angiogenic and antibacterial properties, able to bond to bone. In a study of 147 patients and 837 pedicle screws placed due to degenerative lumbosacral spine disorder, 14.3 % breached the pedicle. New neurological symptoms corresponding to the breach were observed in 25.9 % of patients with pedicle breach, and 89.2 % of the symptomatic breaches were either medially or inferiorly. A preclinical controlled study of novel BAG S53P4 putty showed good biocompatibility, slightly higher intramedullary ossification of putty group compared to the control group, and that the binder agent did not disturb formation of new bone in vivo. The interbody fusion rate was 95.8 % with BAG S53P4 putty as bone graft expander with autograft in clinical lumbosacral interbody fusion, indicating at least as good interbody fusion results as the presently used materials. One early operative subsidence remaining unchanged over the study period was observed with putty.Lannerangan luudutusleikkausten tarkkuuteen ja luutumiseen vaikuttavat tekijät Lannerangan luudutusleikkaus voidaan tehdä oireisessa lannerangan rappeumasairaudessa, kun kivun syyn on osoitettu sijaitsevan rajallisessa määrässä selkärangan toiminnallisia yksikköjä ja kun kipu ei vähene leikkauksettomilla hoidoilla. Leikkauksella voidaan poistaa kipua tuottava selkärangan toiminnallisten yksikköjen liike. Epätarkka pedikkeliruuvien asettaminen voi aiheuttaa neurologisia oireita ja johtaa nopeaan kiinnitysosien irtoamiseen ja rangan epätukevuusoireiden palaamiseen. Suuri osa selkärangan kiinnityslaitteista irtoaa lopulta, jollei luutumista kiinnitettyjen kohtien välillä tapahdu. Vuoden kuluttua luudutusleikkauksesta oireista luutumatonta kiinnityskohtaa nimitetään pseudoartroosiksi. Bioaktiiviset lasit ovat synteettisiä, bioyhteensopivia, osteokonduktiivisia ja osteostimulatiivisia materiaaleja, joilla on angiogeenisiä ja antibakteerisia ominaisuuksia, ja ne voivat sitoutua suoraan luuhun. 147 potilaalle lannerangan rappeumasairauden vuoksi asetetut 837 pedikkeliruuvia käsittävän tutkimuksen mukaan 14.3 % ruuveista rikkoi luisen pedikkelin seinämän. 25.9 %:lla potilaista, joilla ruuvi läpäisi pedikkelin seinämän, ilmeni uusia neurologisia oireita, ja 89.2 %:lla oireisista potilaista pedikkeliruuvi läpäisi pedikkelin seinämän mediaalisesti tai inferiorisesti. Prekliinisessä kontrolloidussa tutkimuksessa uudenlainen bioaktiivisesta lasista valmistettu S53P4 luunkorviketahna todettiin bioyhteensopivaksi, ja sen avulla saavutettiin hieman vertailuryhmää parempi luutuminen luuydinontelossa. Tahnan sidosaineen ei eläinkokeessa todettu häiritsevän luun muodostumista. Kliinisessä tutkimuksessa saavutettiin 95.8 %:n luutuminen käytettäessä S53P4 biolasitahnaa yhdessä oman luun kanssa lannerangan nikamasolmujen välisessä luudutuksessa. Siten yhdessä oman luun kanssa käytettäessä S53P4 biolasitahnalla saadaan aikaan vähintään yhtä hyvä nikamasolmujen välinen luutuminen kuin nykyisin käytettävillä synteettisillä luunkorvikkeilla. Tutkimuksessa todettiin yksi leikkauksen yhteydessä tapahtunut nikamasolmujen välisen implantin päätelevyyn painuminen, jonka suuruus ei muuttunut seurantakuvantamisissa

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not

    CT Scanning

    Get PDF
    Since its introduction in 1972, X-ray computed tomography (CT) has evolved into an essential diagnostic imaging tool for a continually increasing variety of clinical applications. The goal of this book was not simply to summarize currently available CT imaging techniques but also to provide clinical perspectives, advances in hybrid technologies, new applications other than medicine and an outlook on future developments. Major experts in this growing field contributed to this book, which is geared to radiologists, orthopedic surgeons, engineers, and clinical and basic researchers. We believe that CT scanning is an effective and essential tools in treatment planning, basic understanding of physiology, and and tackling the ever-increasing challenge of diagnosis in our society

    Development of an augmented reality guided computer assisted orthopaedic surgery system

    Get PDF
    Previously held under moratorium from 1st December 2016 until 1st December 2021.This body of work documents the developed of a proof of concept augmented reality guided computer assisted orthopaedic surgery system – ARgCAOS. After initial investigation a visible-spectrum single camera tool-mounted tracking system based upon fiducial planar markers was implemented. The use of visible-spectrum cameras, as opposed to the infra-red cameras typically used by surgical tracking systems, allowed the captured image to be streamed to a display in an intelligible fashion. The tracking information defined the location of physical objects relative to the camera. Therefore, this information allowed virtual models to be overlaid onto the camera image. This produced a convincing augmented experience, whereby the virtual objects appeared to be within the physical world, moving with both the camera and markers as expected of physical objects. Analysis of the first generation system identified both accuracy and graphical inadequacies, prompting the development of a second generation system. This too was based upon a tool-mounted fiducial marker system, and improved performance to near-millimetre probing accuracy. A resection system was incorporated into the system, and utilising the tracking information controlled resection was performed, producing sub-millimetre accuracies. Several complications resulted from the tool-mounted approach. Therefore, a third generation system was developed. This final generation deployed a stereoscopic visible-spectrum camera system affixed to a head-mounted display worn by the user. The system allowed the augmentation of the natural view of the user, providing convincing and immersive three dimensional augmented guidance, with probing and resection accuracies of 0.55±0.04 and 0.34±0.04 mm, respectively.This body of work documents the developed of a proof of concept augmented reality guided computer assisted orthopaedic surgery system – ARgCAOS. After initial investigation a visible-spectrum single camera tool-mounted tracking system based upon fiducial planar markers was implemented. The use of visible-spectrum cameras, as opposed to the infra-red cameras typically used by surgical tracking systems, allowed the captured image to be streamed to a display in an intelligible fashion. The tracking information defined the location of physical objects relative to the camera. Therefore, this information allowed virtual models to be overlaid onto the camera image. This produced a convincing augmented experience, whereby the virtual objects appeared to be within the physical world, moving with both the camera and markers as expected of physical objects. Analysis of the first generation system identified both accuracy and graphical inadequacies, prompting the development of a second generation system. This too was based upon a tool-mounted fiducial marker system, and improved performance to near-millimetre probing accuracy. A resection system was incorporated into the system, and utilising the tracking information controlled resection was performed, producing sub-millimetre accuracies. Several complications resulted from the tool-mounted approach. Therefore, a third generation system was developed. This final generation deployed a stereoscopic visible-spectrum camera system affixed to a head-mounted display worn by the user. The system allowed the augmentation of the natural view of the user, providing convincing and immersive three dimensional augmented guidance, with probing and resection accuracies of 0.55±0.04 and 0.34±0.04 mm, respectively

    Infective/inflammatory disorders

    Get PDF

    The radiological investigation of musculoskeletal tumours : chairperson's introduction

    No full text