111 research outputs found

    Toward certifiable optimal motion planning for medical steerable needles

    Get PDF
    Medical steerable needles can follow 3D curvilinear trajectories to avoid anatomical obstacles and reach clinically significant targets inside the human body. Automating steerable needle procedures can enable physicians and patients to harness the full potential of steerable needles by maximally leveraging their steerability to safely and accurately reach targets for medical procedures such as biopsies. For the automation of medical procedures to be clinically accepted, it is critical from a patient care, safety, and regulatory perspective to certify the correctness and effectiveness of the planning algorithms involved in procedure automation. In this paper, we take an important step toward creating a certifiable optimal planner for steerable needles. We present an efficient, resolution-complete motion planner for steerable needles based on a novel adaptation of multi-resolution planning. This is the first motion planner for steerable needles that guarantees to compute in finite time an obstacle-avoiding plan (or notify the user that no such plan exists), under clinically appropriate assumptions. Based on this planner, we then develop the first resolution-optimal motion planner for steerable needles that further provides theoretical guarantees on the quality of the computed motion plan, that is, global optimality, in finite time. Compared to state-of-the-art steerable needle motion planners, we demonstrate with clinically realistic simulations that our planners not only provide theoretical guarantees but also have higher success rates, have lower computation times, and result in higher quality plans

    Multi Degree of Freedom Hinge Joints Embedded on Tubes for Miniature Steerable Medical Devices

    Get PDF
    With the proliferation of successful minimally invasive surgical techniques, comes the challenge of shrinking the size of surgical instruments further to facilitate use in applications such as neurosurgery, pediatric surgery, and needle procedures. The present thesis introduces laser machined, multi-degree-of-freedom (DoF) hinge joints embedded on tubes, as a possible means to realize such miniature instruments without the need for any assembly. A method to design such a joint for an estimated range of motion is explored by using geometric principles. A geometric model is developed to characterize the joint and relate it to the laser machining parameters, design parameters, and the workpiece parameters. The extent of interference between the moving parts of the joint can be used to predict the range of motion of the joint for rigid tubes and for future design optimization. The total usable workspace is estimated using kinematic principles for joints in series and for two sets of orthogonal joints. The predicted range of motion was compared to the measured values for fabricated samples of different hinge sizes and kerf dimensions, and it was shown that the predicted values are close to the measured ranges across samples. The embedded hinge joints described in this thesis could be used for micro-robotic applications and minimally invasive surgical devices for neurosurgery and pediatric surgery. Our work can open up avenues to a new class of miniature robotic medical devices with hinge joints and a usable channel for drug delivery

    Tendon-Driven Notched Needle for Robot-Assisted Prostate Interventions

    Get PDF
    M.S

    A Novel Bio-Inspired Insertion Method for Application to Next Generation Percutaneous Surgical Tools

    No full text
    The use of minimally invasive techniques can dramatically improve patient outcome from neurosurgery, with less risk, faster recovery, and better cost effectiveness when compared to conventional surgical intervention. To achieve this, innovative surgical techniques and new surgical instruments have been developed. Nevertheless, the simplest and most common interventional technique for brain surgery is needle insertion for either diagnostic or therapeutic purposes. The work presented in this thesis shows a new approach to needle insertion into soft tissue, focussing on soft tissue-needle interaction by exploiting microtextured topography and the unique mechanism of a reciprocating motion inspired by the ovipositor of certain parasitic wasps. This thesis starts by developing a brain-like phantom which I was shown to have mechanical properties similar to those of neurological tissue during needle insertion. Secondly, a proof-of-concept of the bio-inspired insertion method was undertaken. Based on this finding, the novel method of a multi-part probe able to penetrate a soft substrate by reciprocal motion of each segment is derived. The advantages of the new insertion method were investigated and compared with a conventional needle insertion in terms of needle-tissue interaction. The soft tissue deformation and damage were also measured by exploiting the method of particle image velocimetry. Finally, the thesis proposes the possible clinical application of a biologically-inspired surface topography for deep brain electrode implantation. As an adjunct to this work, the reciprocal insertion method described here fuelled the research into a novel flexible soft tissue probe for percutaneous intervention, which is able to steer along curvilinear trajectories within a compliant medium. Aspects of this multi-disciplinary research effort on steerable robotic surgery are presented, followed by a discussion of the implications of these findings within the context of future work

    A Novel Flexible and Steerable Probe for Minimally Invasive Soft Tissue Intervention

    No full text
    Current trends in surgical intervention favour a minimally invasive (MI) approach, in which complex procedures are performed through increasingly small incisions. Specifically, in neurosurgery, there is a need for minimally invasive keyhole access, which conflicts with the lack of maneuverability of conventional rigid instruments. In an attempt to address this fundamental shortcoming, this thesis describes the concept design, implementation and experimental validation of a novel flexible and steerable probe, named “STING” (Soft Tissue Intervention and Neurosurgical Guide), which is able to steer along curvilinear trajectories within a compliant medium. The underlying mechanism of motion of the flexible probe, based on the reciprocal movement of interlocked probe segments, is biologically inspired and was designed around the unique features of the ovipositor of certain parasitic wasps. Such insects are able to lay eggs by penetrating different kinds of “host” (e.g. wood, larva) with a very thin and flexible multi-part channel, thanks to a micro-toothed surface topography, coupled with a reciprocating “push and pull” motion of each segment. This thesis starts by exploring these foundations, where the “microtexturing” of the surface of a rigid probe prototype is shown to facilitate probe insertion into soft tissue (porcine brain), while gaining tissue purchase when the probe is tensioned outwards. Based on these findings, forward motion into soft tissue via a reciprocating mechanism is then demonstrated through a focused set of experimental trials in gelatine and agar gel. A flexible probe prototype (10 mm diameter), composed of four interconnected segments, is then presented and shown to be able to steer in a brain-like material along multiple curvilinear trajectories on a plane. The geometry and certain key features of the probe are optimised through finite element models, and a suitable actuation strategy is proposed, where the approach vector of the tip is found to be a function of the offset between interlocked segments. This concept of a “programmable bevel”, which enables the steering angle to be chosen with virtually infinite resolution, represents a world-first in percutaneous soft tissue surgery. The thesis concludes with a description of the integration and validation of a fully functional prototype within a larger neurosurgical robotic suite (EU FP7 ROBOCAST), which is followed by a summary of the corresponding implications for future work

    Biomechanics of a parasitic wasp ovipositor : Probing for answers

    Get PDF
    Insects such as mosquitoes, true bugs, and parasitic wasps, probe for resources hidden in various substrates. The resources are often, located deep within the substrate and can only be reached with long and thin (slender) probes. Such probes can, however, easily bend or break (buckle) when pushed inside the substrate, which makes probing a challenging task. Nevertheless, the mentioned insects use their probes repeatedly throughout their lifetime without apparent damage. Furthermore, the probes are also used for sensing the targets, can be steered during insertion, and can transport both fluids (e.g. blood, phloem sap) and eggs. Insect probes seem highly versatile structures that satisfy many functional requirements, including buckling avoidance, steering, sensing, and transport. Similar requirements also hold for minimally invasive medical procedures, where slender tools are used to minimize damage to the patient. Understanding the probing process in insects can bring insights in the insect ecology and evolution and it may also help in the development of novel surgical tools. In this thesis, I focus on the mechanical and motor adaptations of insect probing, while other aspects are only briefly discussed. In chapter 2, we review the literature on the probing structures and their operating principles across mosquitoes, parasitic wasps, and hemipterans. Probes are either modified mouthparts (mosquitoes, true bugs) or special tubular outgrowths of the abdomen (parasitic wasps). Despite having different developmental origins, the probes share three major morphological characteristics, which may reflect the shared functional requirements of buckling avoidance and steering: (i) the probes consist of multiple, interconnected elements that can slide along each other, (ii) the probe diameters are very small, which leaves no space for internal musculature, and (iii) the distal ends (tips) of the probe elements are asymmetric and often bear various serrations, hooks, bulges, or notches. How such slender multi-element probes avoid buckling during insertion has been hypothesized in the so-called push–pull mechanism. According to this mechanism, the probe is inserted into the substrate by reciprocal movements of the elements. The insects therefore simultaneously push on some of the probe elements, while pulling on the others. The tip serrations are directed such, that they primarily increase the friction upon pulling of the elements. This puts the pulled elements under tension and makes them effectively stiffer in bending (like when pulling a rope). The elements under tension can serve as guides along which the other elements are pushed inside the substrate without the risk of buckling. The insect alternates the pushing and pulling between the elements to incrementally insert the probe in the substrate. This mechanism has, however, never been quantified in insects and it was hitherto unknown whether the animals rely on it during probing. The probe tip asymmetry presumably facilitates steering. The asymmetric tip geometry leads to asymmetric reaction forces from the substrate on the tip during insertion, which push the probe tip sideways into a curved path. Controlling the tip geometry therefore allows for control of probing direction. Although offsetting the elements by sliding already changes the shape of the probe tip, these changes might be too small to induce the necessary change of probing direction. A number of mechanisms that enhance the tip asymmetry during the sliding of the elements have been suggested. However, few mechanisms have been observed or studied in vivo, so it is not completely clear how insects steer with their probes. Additionally, the effect of the substrate on both the steering and insertion mechanisms is unknown. To understand the biomechanics of insect probing, we investigated the probing behaviour of the braconid parasitic wasp Diachasmimorpha longicaudata. This is an ideal species for studying the buckling avoidance and steering, because it: (i) possess a slender ovipositor several millimetres in length, (ii) probes into solid material (e.g. citrus fruits), and (iii) attack fruit-fly larvae that are freely moving within the substrate (i.e. steering can be expected). The ovipositor of D. longicaudata is similar to other hymenopterans and consists of three interconnected elements (valves), one dorsal and two ventral ones. The interconnection is a tongue-and-groove mechanism, which allows for sliding of the valves, but prevents their separation. The ovipositor has an asymmetric tip—the distal end of the dorsal valve is enlarged (bulge), while the ventral valve tips have harpoon-like serrations. Additionally, just proximal to the bulge of the dorsal valve, the ovipositor is characteristically bent in an S-shape. This seems to be a feature present only in D. longicaudata and closely related species. The wasps also possess a pair of sheaths that envelop the ovipositor at rest and throughout most of the probing process, but do not penetrate into the substrate. In chapter 3, we studied the kinematics of ovipositor insertion into translucent, artificial substrates of various stiffnesses. Ovipositor insertion was filmed in a three camera setup, which allowed us to reconstruct the ovipositor insertion in 3D, while also monitoring the orientation of the insect’s body. We discovered that the wasps can explore a wide range of the substrate by probing in any direction with respect to their body orientation from a single puncture point. Probing range and speed decreased with increasing substrate stiffness. Wasps used two strategies of ovipositor insertion. In soft substrates, all ovipositor valves were pushed inside the substrate at the same time. In stiff substrates, wasps always moved the valves alternatively, presumably employing the hypothesized push–pull mechanism. We observed that ovipositors can follow curved trajectories inside the substrate. Detailed kinematic analysis revealed that the ovipositors followed a curved path during probing with protracted ventral valve(s). In contrast, probing with protracted dorsal valve resulted in straight trajectories. We linked the changes in the probing direction to the shape changes in the ovipositor tip. When the ventral valves were protracted, they curved towards the dorsal valve, resulting in an enhanced bevel which presumably caused a change in insertion direction. In chapter 4, we investigated the above described steering mechanism by quantifying the bending stiffness (three point bend test) and the geometry (high-resolution computer tomography) of the ovipositor in D. longicaudata. Additionally, we qualitatively assessed the material composition of the valves using fluorescence imaging. The thick dorsal valve bulge might be stiff and could straighten the S-shaped region of the ovipositor during the valve offset, causing bending of the tip. We discovered that the S-shaped region of the ovipositor is significantly softer than its neighbouring regions, which is mostly due to the presence of resilin in the S-shaped region of the ventral valve. Resilin is a rubber-like protein and reduces the stiffness of the otherwise heavily sclerotized valves. Additionally, we showed that the ventral valves have a higher bending stiffness than the dorsal valve along most of their length. The exception is presumably the bulge on the dorsal valve—although we could not directly measure its bending stiffness, its geometrical properties show that it is the thickest (and therefore stiffest) region in the distal end of the ovipositor. Outside the substrate, offsetting of the valves in any direction (i.e. pro- or retraction of the ventral valves) caused a straightening of the S-shaped region of the ovipositor and a curving towards the dorsal side. However, during probing in a substrate, such curving was only observed upon protraction of the ventral valves. We hypothesize this is due to the interaction of the ovipositor with the substrate. Namely, the bevelled ventral valve tips generate substrate reaction forces that promote dorsal curving, while the bevelled tip of the dorsal valve generates substrate forces that promote ventral bending. The interaction between the ventral and dorsal valves straightens the S-shaped region of the ovipositor and enhances dorsal curving. This therefore facilitates strong shape changes of the tip only upon protraction of the ventral valves, while counteracting the ventral curving of the dorsal valve. These opposing mechanisms presumably result in an approximately straight protraction of the dorsal valve. In chapters 2 and 3 we describe how the wasps use the reciprocal valve movements when probing in stiff substrates. As such substrates presumably require strong forces during insertion, the reciprocal valve movements may indeed serve to avoid buckling. However, how the valves are actuated or the forces generated during probing have never been quantified. In chapter 5, we therefore investigated the ovipositor base and the muscles driving the movements of the valves. At the base, the valves attach to plate-like structures that are interconnected with a series of linkages. The muscles attach to these plates and can move them with respect to each other. Such movements also result in the movements of the valves. To analyse the mechanics of this linked system, we performed high-resolution computer tomography scans of wasps in different stages of the probing cycle. This allowed us to compare the configurational changes of the basal plates to the valve offset, and measure the muscle cross-sections and attachment sites. We also calculated the muscle moment arms and estimated the forces and moments of the most relevant musculature actuating the ovipositor movements, by assuming a tensile muscle stress previously reported for insect muscles. For the ventral valves only, we also calculated the forces the valves can exert onto the substrate. The dorsal valve can only be moved by moving the base that is linked inside the abdomen, and therefore force estimation could not be made. The displacement magnitude of the basal plates corresponded to the valve offset, indicating that the valves are indeed moved due to the changes in the arrangement of the basal plates. We also showed that the ventral valve plates move most during the probing cycle, while the magnitude of the dorsal valve plate movements is much smaller. This suggests that the ventral valves move along the dorsal valve, while the dorsal valve moves together with the abdomen during probing. Additionally, in the situation where the animal keeps its abdomen stationary, we estimated the maximal forces actuating the ventral valves. The estimated maximal pushing forces can be higher than the estimated buckling load of the unsupported ovipositor outside the substrate. Assuming the maximal pushing forces are required during probing, antibuckling mechanisms are needed to avoid damaging the ovipositor. Buckling can be limited (prevented) by either supporting the ovipositor outside the substrate with additional sheaths, employing the push–pull mechanism, or both. Subtracting the maximal estimated pushing and pulling forces on the ventral valves, results in a net pushing force that is very close to the buckling threshold of the ovipositor, albeit still slightly higher. The sheaths, although being flexible, might provide the additional support if needed. In this thesis, I show that multi-element probes are inserted into the substrate using reciprocal movements of the individual elements. These movements appear to be necessary in stiff substrates, which presumably require high pushing forces on a single element during probing. This is in accordance with the hypothesis that reciprocal valve movements serve as an anti-buckling mechanism. Additionally, such valve movements are also important for steering of the probe during insertion. The valve offset controls the shape of the probe tip and therefore the net substrate reaction forces that result in bending of the probe. Wasps evolved special structures that enhance the shape changes of their ovipositor tips and facilitate steering. Our findings may be interesting for a broad range of audiences. Entomologists, evolutionary biologists, and ecologists may find them useful when studying the diversification of probing insects, their evolutionary success, or their ecological interactions (e.g. insect–plant, parasite–host). The anti-buckling and steering mechanisms may be helpful when developing novel, man-made probes. These mechanisms allow for minimization of the probe thickness and accurate steering control, which minimizes substrate damage during probing. Our findings may be particularly useful in the development of slender, steerable needles for minimally invasive surgery.</p

    Efficient Motion and Inspection Planning for Medical Robots with Theoretical Guarantees

    Get PDF
    Medical robots enable faster and safer patient care. Continuum medical robots (e.g., steerable needles) have great potential to accomplish procedures with less damage to patients compared to conventional instruments (e.g., reducing puncturing and cutting of tissues). Due to their complexity and degrees of freedom, such robots are often harder and less intuitive for physicians to operate directly. Automating robot-assisted medical procedures can enable physicians and patients to harness the full potential of medical robots in terms of safety, efficiency, accuracy, and precision.Motion planning methods compute motions for a robot that satisfy various constraints and accomplish a specific task, e.g., plan motions for a mobile robot to move to a target spot while avoiding obstacles. Inspection planning is the task of planning motions for a robot to inspect a set of points of interest, and it has applications in domains such as industrial, field, and medical robotics. With motion and inspection planning, medical robots would be able to automatically accomplish tasks like biopsy and endoscopy while minimizing safety risks and damage to the patient. Computing a motion or inspection plan can be computationally hard since we have to consider application-specific constraints, which come from the robotic system due to the mechanical properties of the robot or come from the environment, such as the requirement to avoid critical anatomical structures during the procedure.I develop motion and inspection planning algorithms that focus on efficiency and effectiveness. Given the same computing power, higher efficiency would shorten the procedure time, thus reducing costs and improving patient outcomes. Additionally, for the automation of medical procedures to be clinically accepted, it is critical from a patient care, safety, and regulatory perspective to certify the correctness and effectiveness of the algorithms involved in procedure automation. Therefore, I focus on providing theoretical guarantees to certify the performance of planners. More specifically, it is important to certify if a planner is able to find a plan if one exists (i.e., completeness) and if a planner is able to find a globally optimal plan according to a given metric (i.e., optimality).Doctor of Philosoph

    Challenges of continuum robots in clinical context: a review

    Get PDF
    With the maturity of surgical robotic systems based on traditional rigid-link principles, the rate of progress slowed as limits of size and controllable degrees of freedom were reached. Continuum robots came with the potential to deliver a step change in the next generation of medical devices, by providing better access, safer interactions and making new procedures possible. Over the last few years, several continuum robotic systems have been launched commercially and have been increasingly adopted in hospitals. Despite the clear progress achieved, continuum robots still suffer from design complexity hindering their dexterity and scalability. Recent advances in actuation methods have looked to address this issue, offering alternatives to commonly employed approaches. Additionally, continuum structures introduce significant complexity in modelling, sensing, control and fabrication; topics which are of particular focus in the robotics community. It is, therefore, the aim of the presented work to highlight the pertinent areas of active research and to discuss the challenges to be addressed before the potential of continuum robots as medical devices may be fully realised

    Transcatheter tricuspid valve implantation: A multicentre French study

    Get PDF
    SummaryBackgroundTranscatheter valve-in-valve (VIV) implantation in failing bioprosthesis is an emerging field in cardiology.AimTo report on a French multicentre experience and a literature review of tricuspid VIV implantation.MethodsWe approached different institutions and collected 10 unpublished cases; a literature review identified 71 patients, including our 10 cases. Clinical aspects and haemodynamic data are discussed.ResultsAmong our 10 unpublished cases, the reason for implantation was significant tricuspid stenosis (n=4), significant tricuspid regurgitation (n=1) or mixed lesion (n=5). Implantation was performed under general anaesthesia at mean age 28±17 years. The 22mm Melody valve was implanted in seven patients; the Edwards SAPIEN valve was implanted in three patients. The procedure succeeded in all cases, despite two embolizations in the right cardiac chambers; in both cases, the valve was stabilized close to the tricuspid annulus using a self-expandable stent, before implantation of a second Edwards SAPIEN valve. Functional class improved in all but one case. Mean diastolic gradient decreased from 9±2.45mmHg to 3.65±0.7mmHg (p=0.007); no more than trivial regurgitation was noticed. Among the published cases, the Melody valve was implanted in 41 patients, the Edwards SAPIEN valve in 29 patients and the Braile valve in one patient. Short-term results were similar for our 10 cases, but mid-term results are not yet available.ConclusionsTricuspid VIV implantation using the Melody or Edwards SAPIEN valves is a feasible and effective procedure for selected patients with failing bioprosthesis
    • 

    corecore