971 research outputs found

    Comparing Measured and Theoretical Target Registration Error of an Optical Tracking System

    Get PDF
    The goal of this thesis is to experimentally measure the accuracy of an optical tracking system used in commercial surgical navigation systems. We measure accuracy by constructing a mechanism that allows a tracked target to move with spherical motion (i.e., there exists a single point on the mechanism—the center of the sphere—that does not change position when the tracked target is moved). We imagine that the center of the sphere is the tip of a surgical tool rigidly attached to the tracked target. The location of the tool tip cannot be measured directly by the tracking system (because it is impossible to attach a tracking marker to the tool tip) and must be calculated using the measured location and orientation of the tracking target. Any measurement error in the tracking system will cause the calculated position of the tool tip to change as the target is moved; the spread of the calculated tool tip positions is a measurement of tracking error called the target registration error (TRE). The observed TRE will be compared to an analytic model of TRE to assess the predictions of the analytic model

    EchoFusion: Tracking and Reconstruction of Objects in 4D Freehand Ultrasound Imaging without External Trackers

    Get PDF
    Ultrasound (US) is the most widely used fetal imaging technique. However, US images have limited capture range, and suffer from view dependent artefacts such as acoustic shadows. Compounding of overlapping 3D US acquisitions into a high-resolution volume can extend the field of view and remove image artefacts, which is useful for retrospective analysis including population based studies. However, such volume reconstructions require information about relative transformations between probe positions from which the individual volumes were acquired. In prenatal US scans, the fetus can move independently from the mother, making external trackers such as electromagnetic or optical tracking unable to track the motion between probe position and the moving fetus. We provide a novel methodology for image-based tracking and volume reconstruction by combining recent advances in deep learning and simultaneous localisation and mapping (SLAM). Tracking semantics are established through the use of a Residual 3D U-Net and the output is fed to the SLAM algorithm. As a proof of concept, experiments are conducted on US volumes taken from a whole body fetal phantom, and from the heads of real fetuses. For the fetal head segmentation, we also introduce a novel weak annotation approach to minimise the required manual effort for ground truth annotation. We evaluate our method qualitatively, and quantitatively with respect to tissue discrimination accuracy and tracking robustness.Comment: MICCAI Workshop on Perinatal, Preterm and Paediatric Image analysis (PIPPI), 201

    Técnicas de coste reducido para el posicionamiento del paciente en radioterapia percutánea utilizando un sistema de imágenes ópticas

    Get PDF
    Patient positioning is an important part of radiation therapy which is one of the main solutions for the treatment of malignant tissue in the human body. Currently, the most common patient positioning methods expose healthy tissue of the patient's body to extra dangerous radiations. Other non-invasive positioning methods are either not very accurate or are very costly for an average hospital. In this thesis, we explore the possibility of developing a system comprised of affordable hardware and advanced computer vision algorithms that facilitates patient positioning. Our algorithms are based on the usage of affordable RGB-D sensors, image features, ArUco planar markers, and other geometry registration methods. Furthermore, we take advantage of consumer-level computing hardware to make our systems widely accessible. More specifically, we avoid the usage of approaches that need to take advantage of dedicated GPU hardware for general-purpose computing since they are more costly. In different publications, we explore the usage of the mentioned tools to increase the accuracy of reconstruction/localization of the patient in its pose. We also take into account the visualization of the patient's target position with respect to their current position in order to assist the person who performs patient positioning. Furthermore, we make usage of augmented reality in conjunction with a real-time 3D tracking algorithm for better interaction between the program and the operator. We also solve more fundamental problems about ArUco markers that could be used in the future to improve our systems. These include highquality multi-camera calibration and mapping using ArUco markers plus detection of these markers in event cameras which are very useful in the presence of fast camera movement. In the end, we conclude that it is possible to increase the accuracy of 3D reconstruction and localization by combining current computer vision algorithms with fiducial planar markers with RGB-D sensors. This is reflected in the low amount of error we have achieved in our experiments for patient positioning, pushing forward the state of the art for this application.En el tratamiento de tumores malignos en el cuerpo, el posicionamiento del paciente en las sesiones de radioterapia es una cuestión crucial. Actualmente, los métodos más comunes de posicionamiento del paciente exponen tejido sano del mismo a radiaciones peligrosas debido a que no es posible asegurar que la posición del paciente siempre sea la misma que la que tuvo cuando se planificó la zona a radiar. Los métodos que se usan actualmente, o no son precisos o tienen costes que los hacen inasequibles para ser usados en hospitales con financiación limitada. En esta Tesis hemos analizado la posibilidad de desarrollar un sistema compuesto por hardware de bajo coste y métodos avanzados de visión por ordenador que ayuden a que el posicionamiento del paciente sea el mismo en las diferentes sesiones de radioterapia, con respecto a su pose cuando fue se planificó la zona a radiar. La solución propuesta como resultado de la Tesis se basa en el uso de sensores RGB-D, características extraídas de la imagen, marcadores cuadrados denominados ArUco y métodos de registro de la geometría en la imagen. Además, en la solución propuesta, se aprovecha la existencia de hardware convencional de bajo coste para hacer nuestro sistema ampliamente accesible. Más específicamente, evitamos el uso de enfoques que necesitan aprovechar GPU, de mayores costes, para computación de propósito general. Se han obtenido diferentes publicaciones para conseguir el objetivo final. Las mismas describen métodos para aumentar la precisión de la reconstrucción y la localización del paciente en su pose, teniendo en cuenta la visualización de la posición ideal del paciente con respecto a su posición actual, para ayudar al profesional que realiza la colocación del paciente. También se han propuesto métodos de realidad aumentada junto con algoritmos para seguimiento 3D en tiempo real para conseguir una mejor interacción entre el sistema ideado y el profesional que debe realizar esa labor. De forma añadida, también se han propuesto soluciones para problemas fundamentales relacionados con el uso de marcadores cuadrados que han sido utilizados para conseguir el objetivo de la Tesis. Las soluciones propuestas pueden ser empleadas en el futuro para mejorar otros sistemas. Los problemas citados incluyen la calibración y el mapeo multicámara de alta calidad utilizando los marcadores y la detección de estos marcadores en cámaras de eventos, que son muy útiles en presencia de movimientos rápidos de la cámara. Al final, concluimos que es posible aumentar la precisión de la reconstrucción y localización en 3D combinando los actuales algoritmos de visión por ordenador, que usan marcadores cuadrados de referencia, con sensores RGB-D. Los resultados obtenidos con respecto al error que el sistema obtiene al reproducir el posicionamiento del paciente suponen un importante avance en el estado del arte de este tópico

    Ultrasound-Augmented Laparoscopy

    Get PDF
    Laparoscopic surgery is perhaps the most common minimally invasive procedure for many diseases in the abdomen. Since the laparoscopic camera provides only the surface view of the internal organs, in many procedures, surgeons use laparoscopic ultrasound (LUS) to visualize deep-seated surgical targets. Conventionally, the 2D LUS image is visualized in a display spatially separate from that displays the laparoscopic video. Therefore, reasoning about the geometry of hidden targets requires mentally solving the spatial alignment, and resolving the modality differences, which is cognitively very challenging. Moreover, the mental representation of hidden targets in space acquired through such cognitive medication may be error prone, and cause incorrect actions to be performed. To remedy this, advanced visualization strategies are required where the US information is visualized in the context of the laparoscopic video. To this end, efficient computational methods are required to accurately align the US image coordinate system with that centred in the camera, and to render the registered image information in the context of the camera such that surgeons perceive the geometry of hidden targets accurately. In this thesis, such a visualization pipeline is described. A novel method to register US images with a camera centric coordinate system is detailed with an experimental investigation into its accuracy bounds. An improved method to blend US information with the surface view is also presented with an experimental investigation into the accuracy of perception of the target locations in space

    Toward Real-Time Video-Enhanced Augmented Reality for Medical Visualization and Simulation

    Get PDF
    In this work we demonstrate two separate forms of augmented reality environments for use with minimally-invasive surgical techniques. In Chapter 2 it is demonstrated how a video feed from a webcam, which could mimic a laparoscopic or endoscopic camera used during an interventional procedure, can be used to identify the pose of the camera with respect to the viewed scene and augment the video feed with computer-generated information, such as rendering of internal anatomy not visible beyond the image surface, resulting in a simple augmented reality environment. Chapter 3 details our implementation of a similar system to the one previously mentioned, albeit with an external tracking system. Additionally, we discuss the challenges and considerations for expanding this system to support an external tracking system, specifically the Polaris Spectra optical tracker. Because of the relocation of the tracking origin to a point other than the camera center, there is an additional registration step necessary to establish the position of all components within the scene. This modification is expected to increase accuracy and robustness of the system

    Vision-Based Three Dimensional Hand Interaction In Markerless Augmented Reality Environment

    Get PDF
    Kemunculan realiti tambahan membolehkan objek maya untuk wujud bersama dengan dunia sebenar dan ini memberi kaedah baru untuk berinteraksi dengan objek maya. Sistem realiti tambahan memerlukan penunjuk tertentu, seperti penanda untuk menentukan bagaimana objek maya wujud dalam dunia sebenar. Penunjuk tertentu mesti diperolehi untuk menggunakan sistem realiti tambahan, tetapi susah untuk seseorang mempunyai penunjuk tersebut pada bila-bila masa. Tangan manusia, yang merupakan sebahagian dari badan manusia dapat menyelesaikan masalah ini. Selain itu, tangan boleh digunakan untuk berinteraksi dengan objek maya dalam dunia realiti tambahan. Tesis ini membentangkan sebuah sistem realiti tambahan yang menggunakan tangan terbuka untuk pendaftaran objek maya dalam persekitaran sebenar dan membolehkan pengguna untuk menggunakan tangan yang satu lagi untuk berinteraksi dengan objek maya yang ditambahkan dalam tiga-matra. Untuk menggunakan tangan untuk pendaftaran dan interaksi dalam realiti tambahan, postur dan isyarat tangan pengguna perlu dikesan. The advent of augmented reality (AR) enables virtual objects to be superimposed on the real world and provides a new way to interact with the virtual objects. AR system requires an indicator to determine for how the virtual objects aligned in the real world. The indicator must first be obtained to access to a particular AR system. It may be inconvenient to have the indicator in reach at all time. Human hand, which is part of the human body may be a solution for this. Besides, hand is also a promising tool for interaction with virtual objects in AR environment. This thesis presents a markerless Augmented Reality system which utilizes outstretched hand for registration of virtual objects in the real environment and enables the users to have three dimensional (3D) interaction with the augmented virtual objects. To employ the hand for registration and interaction in AR, hand postures and gestures that the user perform has to be recognized

    On uncertainty propagation in image-guided renal navigation: Exploring uncertainty reduction techniques through simulation and in vitro phantom evaluation

    Get PDF
    Image-guided interventions (IGIs) entail the use of imaging to augment or replace direct vision during therapeutic interventions, with the overall goal is to provide effective treatment in a less invasive manner, as an alternative to traditional open surgery, while reducing patient trauma and shortening the recovery time post-procedure. IGIs rely on pre-operative images, surgical tracking and localization systems, and intra-operative images to provide correct views of the surgical scene. Pre-operative images are used to generate patient-specific anatomical models that are then registered to the patient using the surgical tracking system, and often complemented with real-time, intra-operative images. IGI systems are subject to uncertainty from several sources, including surgical instrument tracking / localization uncertainty, model-to-patient registration uncertainty, user-induced navigation uncertainty, as well as the uncertainty associated with the calibration of various surgical instruments and intra-operative imaging devices (i.e., laparoscopic camera) instrumented with surgical tracking sensors. All these uncertainties impact the overall targeting accuracy, which represents the error associated with the navigation of a surgical instrument to a specific target to be treated under image guidance provided by the IGI system. Therefore, understanding the overall uncertainty of an IGI system is paramount to the overall outcome of the intervention, as procedure success entails achieving certain accuracy tolerances specific to individual procedures. This work has focused on studying the navigation uncertainty, along with techniques to reduce uncertainty, for an IGI platform dedicated to image-guided renal interventions. We constructed life-size replica patient-specific kidney models from pre-operative images using 3D printing and tissue emulating materials and conducted experiments to characterize the uncertainty of both optical and electromagnetic surgical tracking systems, the uncertainty associated with the virtual model-to-physical phantom registration, as well as the uncertainty associated with live augmented reality (AR) views of the surgical scene achieved by enhancing the pre-procedural model and tracked surgical instrument views with live video views acquires using a camera tracked in real time. To better understand the effects of the tracked instrument calibration, registration fiducial configuration, and tracked camera calibration on the overall navigation uncertainty, we conducted Monte Carlo simulations that enabled us to identify optimal configurations that were subsequently validated experimentally using patient-specific phantoms in the laboratory. To mitigate the inherent accuracy limitations associated with the pre-procedural model-to-patient registration and their effect on the overall navigation, we also demonstrated the use of tracked video imaging to update the registration, enabling us to restore targeting accuracy to within its acceptable range. Lastly, we conducted several validation experiments using patient-specific kidney emulating phantoms using post-procedure CT imaging as reference ground truth to assess the accuracy of AR-guided navigation in the context of in vitro renal interventions. This work helped find answers to key questions about uncertainty propagation in image-guided renal interventions and led to the development of key techniques and tools to help reduce optimize the overall navigation / targeting uncertainty

    DYNAMIC MEASUREMENT OF THREE-DIMENSIONAL MOTION FROM SINGLE-PERSPECTIVE TWO-DIMENSIONAL RADIOGRAPHIC PROJECTIONS

    Get PDF
    The digital evolution of the x-ray imaging modality has spurred the development of numerous clinical and research tools. This work focuses on the design, development, and validation of dynamic radiographic imaging and registration techniques to address two distinct medical applications: tracking during image-guided interventions, and the measurement of musculoskeletal joint kinematics. Fluoroscopy is widely employed to provide intra-procedural image-guidance. However, its planar images provide limited information about the location of surgical tools and targets in three-dimensional space. To address this limitation, registration techniques, which extract three-dimensional tracking and image-guidance information from planar images, were developed and validated in vitro. The ability to accurately measure joint kinematics in vivo is an important tool in studying both normal joint function and pathologies associated with injury and disease, however it still remains a clinical challenge. A technique to measure joint kinematics from single-perspective x-ray projections was developed and validated in vitro, using clinically available radiography equipmen
    corecore