579 research outputs found

    A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals

    Get PDF
    The noninvasive peripheral oxygen saturation (SpO2) and the pulse rate can be extracted from photoplethysmography (PPG) signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects’ PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO2 and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis

    Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review.

    Get PDF
    Breathing rate (BR) is a key physiological parameter used in a range of clinical settings. Despite its diagnostic and prognostic value, it is still widely measured by counting breaths manually. A plethora of algorithms have been proposed to estimate BR from the electrocardiogram (ECG) and pulse oximetry (photoplethysmogram, PPG) signals. These BR algorithms provide opportunity for automated, electronic, and unobtrusive measurement of BR in both healthcare and fitness monitoring. This paper presents a review of the literature on BR estimation from the ECG and PPG. First, the structure of BR algorithms and the mathematical techniques used at each stage are described. Second, the experimental methodologies that have been used to assess the performance of BR algorithms are reviewed, and a methodological framework for the assessment of BR algorithms is presented. Third, we outline the most pressing directions for future research, including the steps required to use BR algorithms in wearable sensors, remote video monitoring, and clinical practice

    Characterization and processing of novel neck photoplethysmography signals for cardiorespiratory monitoring

    Get PDF
    Epilepsy is a neurological disorder causing serious brain seizures that severely affect the patients' quality of life. Sudden unexpected death in epilepsy (SUDEP), for which no evident decease reason is found after post-mortem examination, is a common cause of mortality. The mechanisms leading to SUDEP are uncertain, but, centrally mediated apneic respiratory dysfunction, inducing dangerous hypoxemia, plays a key role. Continuous physiological monitoring appears as the only reliable solution for SUDEP prevention. However, current seizure-detection systems do not show enough sensitivity and present a high number of intolerable false alarms. A wearable system capable of measuring several physiological signals from the same body location, could efficiently overcome these limitations. In this framework, a neck wearable apnea detection device (WADD), sensing airflow through tracheal sounds, was designed. Despite the promising performance, it is still necessary to integrate an oximeter sensor into the system, to measure oxygen saturation in blood (SpO2) from neck photoplethysmography (PPG) signals, and hence, support the apnea detection decision. The neck is a novel PPG measurement site that has not yet been thoroughly explored, due to numerous challenges. This research work aims to characterize neck PPG signals, in order to fully exploit this alternative pulse oximetry location, for precise cardiorespiratory biomarkers monitoring. In this thesis, neck PPG signals were recorded, for the first time in literature, in a series of experiments under different artifacts and respiratory conditions. Morphological and spectral characteristics were analyzed in order to identify potential singularities of the signals. The most common neck PPG artifacts critically corrupting the signal quality, and other breathing states of interest, were thoroughly characterized in terms of the most discriminative features. An algorithm was further developed to differentiate artifacts from clean PPG signals. Both, the proposed characterization and classification model can be useful tools for researchers to denoise neck PPG signals and exploit them in a variety of clinical contexts. In addition to that, it was demonstrated that the neck also offered the possibility, unlike other body parts, to extract the Jugular Venous Pulse (JVP) non-invasively. Overall, the thesis showed how the neck could be an optimum location for multi-modal monitoring in the context of diseases affecting respiration, since it not only allows the sensing of airflow related signals, but also, the breathing frequency component of the PPG appeared more prominent than in the standard finger location. In this context, this property enabled the extraction of relevant features to develop a promising algorithm for apnea detection in near-real time. These findings could be of great importance for SUDEP prevention, facilitating the investigation of the mechanisms and risk factors associated to it, and ultimately reduce epilepsy mortality.Open Acces

    Blood Pressure Estimation from Electrocardiogram and Photoplethysmography Signals Using Continuous Wavelet Transform and Convolutional Neural Network

    Get PDF
    Cuff-less and continuous blood pressure (BP) measurement has recently become an active research area in the field of remote healthcare monitoring. There is a growing demand for automated BP estimation and monitoring for various long-term and chronic conditions. Automated BP monitoring can produce a good amount of rich health data, which increases the chance of early diagnosis and treatments that are critical for a long-term condition such as hypertension and Cardiovascular diseases (CVDs). However, mining and processing this vast amount of data is challenging, which is aimed to address in this research. We employed a continuous wavelet transform (CWT) and a deep convolutional neural network (CNN) to estimate the BP. The electrocardiogram (ECG), photoplethysmography (PPG) and arterial blood pressure (ABP) signals were extracted from the online Medical Information Mart for Intensive Care (MIMIC III) database. The scalogram of each signal was created and used for training and testing our proposed CNN model that can implicitly learn to extract the descriptive features from the training data. This study achieved a promising BP estimation approach has been achieved without employing engineered feature extraction that is comparable with previous works. Experimental results demonstrated a low root mean squere error (RMSE) rate of 3.36 mmHg and a high accuracy of 86.3% for BP estimations. The proposed CNN-based model can be considered as a reliable and feasible approach to estimate BP for continuous remote healthcare monitoring

    Using Bayesian optimization and wavelet decomposition in GPU for arterial blood pressure estimation

    Get PDF
    Continuous monitoring of arterial blood pressure (ABP) of patients in hospital is currently carried out in an invasive way, which could represent a risk for them. In this paper, a noninvasive methodology to optimize ABP estimators using electrocardiogram and photoplethysmography signals is proposed. For this, the XGBoost machine learning model, optimized with Bayesian techniques, is executed in a Graphics Processing Unit, which drastically reduces execution time. The methodology is evaluated using the MIMIC-III Waveform Database. Systolic and diastolic pressures are estimated with mean absolute error values of 15.85 and 11.59 mmHg, respectively, similar to those of the state of the art. The main advantage of the proposed methodology with respect to others of the current state of the art is that it allows the optimization of the estimator model to be performed automatically and more efficiently at the computational level for the data available. Clinical Relevance— This approach has the advantage of using noninvasive methods to continuously monitor patient's arterial blood pressure, reducing the risk for patientsAgencia Gallega de Innovación | Ref. IN845D-2020/29Agencia Gallega de Innovación | Ref. IN607B-2021/1

    Evaluation of PPG Biometrics for Authentication in different states

    Full text link
    Amongst all medical biometric traits, Photoplethysmograph (PPG) is the easiest to acquire. PPG records the blood volume change with just combination of Light Emitting Diode and Photodiode from any part of the body. With IoT and smart homes' penetration, PPG recording can easily be integrated with other vital wearable devices. PPG represents peculiarity of hemodynamics and cardiovascular system for each individual. This paper presents non-fiducial method for PPG based biometric authentication. Being a physiological signal, PPG signal alters with physical/mental stress and time. For robustness, these variations cannot be ignored. While, most of the previous works focused only on single session, this paper demonstrates extensive performance evaluation of PPG biometrics against single session data, different emotions, physical exercise and time-lapse using Continuous Wavelet Transform (CWT) and Direct Linear Discriminant Analysis (DLDA). When evaluated on different states and datasets, equal error rate (EER) of 0.5%0.5\%-6%6\% was achieved for 4545-6060s average training time. Our CWT/DLDA based technique outperformed all other dimensionality reduction techniques and previous work.Comment: Accepted at 11th IAPR/IEEE International Conference on Biometrics, 2018. 6 pages, 6 figure

    Peak Detection and HRV Feature Evaluation on ECG and PPG Signals

    Get PDF
    Publisher Copyright: © 2022 by the authors. Licensee MDPI, Basel, Switzerland.Heart Rate Variability (HRV) evaluates the autonomic nervous system regulation and can be used as a monitoring tool in conditions such as cardiovascular diseases, neuropathies and sleep staging. It can be extracted from the electrocardiogram (ECG) and the photoplethysmogram (PPG) signals. Typically, the HRV is obtained from the ECG processing. Being the PPG sensor widely used in clinical setups for physiological parameters monitoring such as blood oxygenation and ventilatory rate, the question arises regarding the PPG adequacy for HRV extraction. There is not a consensus regarding the PPG being able to replace the ECG in the HRV estimation. This work aims to be a contribution to this research area by comparing the HRV estimation obtained from simultaneously acquired ECG and PPG signals from forty subjects. A peak detection method is herein introduced based on the Hilbert transform: Hilbert Double Envelope Method (HDEM). Two other peak detector methods were also evaluated: Pan-Tompkins and Wavelet-based. HRV parameters for time, frequency and the non-linear domain were calculated for each algorithm and the Pearson correlation, T-test and RMSE were evaluated. The HDEM algorithm showed the best overall results with a sensitivity of 99.07% and 99.45% for the ECG and the PPG signals, respectively. For this algorithm, a high correlation and no significant differences were found between HRV features and the gold standard, for the ECG and PPG signals. The results show that the PPG is a suitable alternative to the ECG for HRV feature extraction.publishersversionpublishe
    corecore