1,199 research outputs found

    A Fault Diagnosis Scheme Based on the Normalized Indexes of the Images eccentricity for a Multilevel Converter of a Switched Reluctance Motor Drive

    Get PDF
    Trabalho apresentado em ICRERA 2022, 18-21 setembro 2022, Istambul, TurquiaThis paper addresses the fault detection and diagnosis of a fault in the switches of the Switched Reluctance Machine (SRM) power electronic converter. Due to the advantages of using multilevel converters with these machines, a fault detection and diagnosis algorithm is proposed for this converter. The topology under consideration is the asymmetric Neutral Point Clamped (ANPC), and the algorithm was developed to detect open and short circuit faults. The proposed algorithm is based on an approach that discriminates eccentricity of the images formed by the converter voltages. This discrimination is realized through the development of normalized indexes based on the entropy theory. Besides the different fault type the algorithm is also able to detect the transistor under fault. The possibility to implement the proposed approach will be verified through simulation tests.N/

    Short-circuit fault analysis and isolation strategy for matrix converters

    Get PDF
    The behavior of matrix converter (MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses (HSFs) for MC short-circuit faults are examined and their performances are compared. The behavior of MC drive systems during the fuse action time under different operating conditions is explored. The feasibility of fault-tolerant operation during the fuse action time is also studied. The basic selection laws for the HSFs and the requirements for the passive components of the MC drive system from the point view of short-circuit faults are also discussed. Simulation results are used to demonstrate the feasibility of the proposed isolation strategies

    Open circuit fault detection and diagnosis in matrix converters

    Get PDF
    With the increased use of power electronics in aerospace, automotive, industrial, and energy generation sectors, the demand for highly reliable and power dense solutions has increased. Matrix converters become attractive when taking into account demands for high reliability and high power density. With their lack of large bulky DC-link capacitors, high power densities are possible with the capability to operate with high ambient temperatures. When a power converter needs high reliability, under tight weight and volume constraints, it is often not possible to have an entirely redundant system. Taking into account these constraints it is desirable that the power converter continue to operate even under faulty conditions, albeit with diminished performance in some regard. This paper presents an open circuit switch fault detection and diagnosis system for matrix converters, which has been experimentally validated. The presented system requires no load models, averaging windows or additional sensors, this makes the proposed method fast and low cost

    Data Mining Applications to Fault Diagnosis in Power Electronic Systems: A Systematic Review

    Get PDF

    Advances in Electrical Machine, Power Electronic, and Drive Condition Monitoring and Fault Detection: State of the Art

    Full text link
    © 2015 IEEE. Personal use of this material is permitted. Permissíon from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertisíng or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.[EN] Recently, research concerning electrical machines and drives condition monitoring and fault diagnosis has experienced extraordinarily dynamic activity. The increasing importance of these energy conversion devices and their widespread use in uncountable applications have motivated significant research efforts. This paper presents an analysis of the state of the art in this field. The analyzed contributions were published in most relevant journals and magazines or presented in either specific conferences in the area or more broadly scoped events.Riera-Guasp, M.; Antonino-Daviu, J.; Capolino, G. (2015). Advances in Electrical Machine, Power Electronic, and Drive Condition Monitoring and Fault Detection: State of the Art. IEEE Transactions on Industrial Electronics. 62(3):1746-1759. doi:10.1109/TIE.2014.2375853S1746175962

    Open-phase fault operation on multiphase induction 3 motor drives

    Get PDF
    Hugo Guzman, Ignacio Gonzalez, Federico Barrero and Mario Durán (2015). Open-Phase Fault Operation on Multiphase Induction Motor Drives, Induction Motors - Applications, Control and Fault Diagnostics, Dr. Raul Gregor (Ed.), ISBN: 978-953-51-2207-4, InTech, DOI: 10.5772/60810. Available from: http://www.intechopen.com/books/induction-motors-applications-control-and-fault-diagnostics/open-phase-fault-operation-on-multiphase-induction-motor-drivesMultiphase machines have been recognized in the last few years like an attractive alternative to conventional three-phase ones. This is due to their usefulness in a niche of applications where the reduction in the total power per phase and, mainly, the high overall system reliability and the ability of using the multiphase machine in faulty conditions are required. Electric vehicle and railway traction, all-electric ships, more-electric aircraft or wind power generation systems are examples of up-to-date real applications using multiphase machines, most of them taking advantage of the ability of continuing the operation in faulty conditions. Between the available multiphase machines, symmetrical five-phase induction machines are probably one of the most frequently considered multiphase machines in recent research. However, other multiphase machines have also been used in the last few years due to the development of more powerful microprocessors. This chapter analyzes the behavior of generic n-phase machines (beingn any odd number higher than 3) in faulty operation (considering the most common faulty operation, i.e. the open phase fault). The obtained results will be then particularized to the 5-phase case, where some simulation and experimental results will be presented to show the behavior of the entire system in healthy and faulty conditions. The chapter will be organized as follows: First, the different faults in a multiphase machine are analyzed. Fault conditions are de tailed and explained, and the interest of a multiphase machine in the management of faults is stated. The effect of the open-phase fault operation in the machine model is then studied. A generic n-phase machine is considered, being n any odd number greater than three. The analysis is afterwards particularized to the 5-phase machine, where the open phase fault condition is managed using different control methods and the obtained results are compared. Finally, the conclusions are presented in the last section of the chapter

    Open-Phase Fault Operation on Multiphase Induction Motor Drives

    Get PDF
    Multiphase machines have been recognized in the last few years like an attractive alternative to conventional three-phase ones. This is due to their usefulness in a niche of applications where the reduction in the total power per phase and, mainly, the high overall system reliability and the ability of using the multiphase machine in faulty conditions are required. Electric vehicle and railway traction, all-electric ships, more-electric aircraft or wind power generation systems are examples of up-to-date real applications using multiphase machines, most of them taking advantage of the ability of continuing the operation in faulty conditions. Between the available multiphase machines, symmetrical five-phase induction machines are probably one of the most frequently considered multiphase machines in recent research. However, other multiphase machines have also been used in the last few years due to the development of more powerful microprocessors. This chapter analyzes the behavior of generic n-phase machines (being n any odd number higher than 3) in faulty operation (considering the most common faulty operation, i.e. the open-phase fault). The obtained results will be then particularized to the 5-phase case, where some simulation and experimental results will be presented to show the behavior of the entire system in healthy and faulty conditions. The chapter will be organized as follows: First, the different faults in a multiphase machine are analyzed. Fault conditions are detailed and explained, and the interest of a multiphase machine in the management of faults is stated. The effect of the open-phase fault operation in the machine model is then studied. A generic n-phase machine is considered, being n any odd number greater than three. The analysis is afterwards particularized to the 5-phase machine, where the open-phase fault condition is managed using different control methods and the obtained results are compared. Finally, the conclusions are presented in the last section of the chapter

    Remedial Strategies of T-NPC Three-Level Asymmetric Six-Phase PMSM Drives Based on SVM-DTC

    Get PDF
    corecore