1,621 research outputs found

    Active actuator fault-tolerant control of a wind turbine benchmark model

    Get PDF
    This paper describes the design of an active fault-tolerant control scheme that is applied to the actuator of a wind turbine benchmark. The methodology is based on adaptive filters obtained via the nonlinear geometric approach, which allows to obtain interesting decoupling property with respect to uncertainty affecting the wind turbine system. The controller accommodation scheme exploits the on-line estimate of the actuator fault signal generated by the adaptive filters. The nonlinearity of the wind turbine model is described by the mapping to the power conversion ratio from tip-speed ratio and blade pitch angles. This mapping represents the aerodynamic uncertainty, and usually is not known in analytical form, but in general represented by approximated two-dimensional maps (i.e. look-up tables). Therefore, this paper suggests a scheme to estimate this power conversion ratio in an analytical form by means of a two-dimensional polynomial, which is subsequently used for designing the active fault-tolerant control scheme. The wind turbine power generating unit of a grid is considered as a benchmark to show the design procedure, including the aspects of the nonlinear disturbance decoupling method, as well as the viability of the proposed approach. Extensive simulations of the benchmark process are practical tools for assessing experimentally the features of the developed actuator fault-tolerant control scheme, in the presence of modelling and measurement errors. Comparisons with different fault-tolerant schemes serve to highlight the advantages and drawbacks of the proposed methodology

    Model-based fault detection and isolation for wind turbine

    Get PDF
    In this paper, a quantitative model based method is proposed for early fault detection and diagnosis of wind turbines. The method is based on designing an observer using a model of the system. The observer innovation signal is monitored to detect faults. For application to the wind turbines, a first principles nonlinear model with pitch angle and torque controllers is developed for simulation and then a simplified state space version of the model is derived for design. The fault detection system is designed and optimized to be most sensitive to system faults and least sensitive to system disturbances and noises. A multiobjective optimization method is then employed to solve this dual problem. Simulation results are presented to demonstrate the performance of the proposed method

    Robust fault estimation for wind turbine energy via hybrid systems.

    Get PDF
    The rapid development of modern wind turbine technology has led to increasing demand for improving system reliability and practical concern for robust fault monitoring scheme. This paper presents the investigation of a 5 MW Dynamic Wind Turbine Energy System that was designed to sustain condition monitoring and fault diagnosis with the goal of improving the reliability operations of universal practical control systems. A hybrid stochastic technique is proposed based on an augmented observer combined with eigenstructure assignment for the parameterisation and the genetic algorithm (GA) optimisation to address the attenuation of uncertainty mostly generated by disturbances. Scenarios-based are employed to explore sensor and actuator faults that have direct and indirect impacts on modern wind turbine system, based on monitoring components that are prone to malfunction. The analysis is aimed to determine the effect of concerned simulated faults from uncertainty in respect to environmental disturbances mostly challenged in real-world operations. The efficiency of the proposed approach will improve the reliability performance of wind turbine system states and diagnose uncertain faults simultaneously. The simulation outcomes illustrate the robustness of the dynamic turbine systems with a diagnostic performance to advance the practical solutions for improving reliable systems.N/

    A Markovian jump system approach for the estimation and adaptive diagnosis of decreased power generation in wind farms

    Get PDF
    In this study, a Markovian jump model of the power generation system of a wind turbine is proposed and the authors present a closed-loop model-based observer to estimate the faults related to energy losses. The observer is designed through an H∞-based optimisation problem that optimally fixes the trade-off between the observer fault sensitivity and robustness. The fault estimates are then used in data-based decision mechanisms for achieving fault detection and isolation. The performance of the strategy is then ameliorated in a wind farm (WF) level scheme that uses a bank of the aforementioned observers and decision mechanisms. Finally, the proposed approach is tested using a well-known benchmark in the context of WF fault diagnosis

    Robust fault estimation for stochastic Takagi-Sugeno fuzzy systems

    Get PDF
    Nowadays, industrial plants are calling for high-performance fault diagnosis techniques to meet stringent requirements on system availability and safety in the event of component failures. This paper deals with robust fault estimation problems for stochastic nonlinear systems subject to faults and unknown inputs relying on Takagi-Sugeno fuzzy models. Augmented approach jointly with unknown input observers for stochastic Takagi-Sugeno models is exploited here, which allows one to estimate both considered faults and full system states robustly. The considered unknown inputs can be either completely decoupled or partially decoupled by observers. For the un-decoupled part of unknown inputs, which still influence error dynamics, stochastic input-to-state stability properties are applied to take nonzero inputs into account and sufficient conditions are achieved to guarantee bounded estimation errors under bounded unknown inputs. Linear matrix inequalities are employed to compute gain matrices of the observer, leading to stochastic input-to-state-stable error dynamics and optimization of the estimation performances against un-decoupled unknown inputs. Finally, simulation on wind turbine benchmark model is applied to validate the performances of the suggested fault reconstruction methodologies

    Fault estimation and fault-tolerant control for discrete-time dynamic systems

    Get PDF
    In this paper, a novel discrete-time estimator is proposed, which is employed for simultaneous estimation of system states, and actuator/sensor faults in a discrete-time dynamic system. The existence of the discrete-time simultaneous estimator is proven mathematically. The systematic design procedure for the derivative and proportional observer gains is addressed, enabling the estimation error dynamics to be internally proper and stable, and robust against the effects from the process disturbances, measurement noise, and faults. Based on the estimated fault signals and system states, a discrete-time fault-tolerant design approach is addressed, by which the system may recover the system performance when actuator/sensor faults occur. Finally, the proposed integrated discrete-time fault estimation and fault-tolerant control technique is applied to the vehicle lateral dynamics, which demonstrates the effectiveness of the developed techniques

    Mathematical control of complex systems

    Get PDF
    Copyright © 2013 ZidongWang et al.This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited

    Integrated fault estimation and fault-tolerant control for stochastic systems with Brownian motions

    Get PDF
    This paper presents an integrated robust fault estimation and fault‐tolerant control technique for stochastic systems subjected to Brownian parameter perturbations. The augmented system approach, unknown input observer method, and optimization technique are integrated to achieve robust simultaneous estimates of the system states and the means of faults concerned. Meanwhile, a robust fault‐tolerant control strategy is developed by using actuator and sensor signal compensation techniques. Stochastic linear time‐invariant systems, stochastic systems with Lipschitz nonlinear constraint, and stochastic systems with quadratic inner‐bounded nonlinear constraint are respectively investigated, and the corresponding fault‐tolerant control algorithms are addressed. Finally, the effectiveness of the proposed fault‐tolerant control techniques is demonstrated via the drivetrain system of a 4.8 MW benchmark wind turbine, a 3‐tank system, and a numerical nonlinear model

    Fault estimation and active fault tolerant control for linear parameter varying descriptor systems

    Get PDF
    Starting with the baseline controller design, this paper proposes an integrated approach of active fault tolerant control based on proportional derivative extended state observer (PDESO) for linear parameter varying descriptor systems. The PDESO can simultaneously provide the estimates of the system states, sensor faults, and actuator faults. The L₂ robust performance of the closed-loop system to bounded exogenous disturbance and bounded uncertainty is achieved by a two-step design procedure adapted from the traditional observer-based controller design. Furthermore, an LMI pole-placement region and the L₂ robustness performance are combined into a multiobjective formulation by suitably combing the appropriate LMI descriptions. A parameter-varying system example is given to illustrate the design procedure and the validity of the proposed integrated design approach

    Fault detection and isolation of pitch actuator faults in a floating wind turbine

    Get PDF
    In this work, the problem of detection and isolation of pitch actuator faults in wind turbines (WTs) is addressed. First, interval observers are used by means of the Luenberger observer to obtain an upper and a lower estimated bounds. The main advantage of this approach is that the new bounds enclose the real output measurement within a bounded interval in a guaranteed way under consideration of the uncertainties (in this case noise in the pitch measurement). Finally, residual signals are obtained and processed to detect and isolate the different faults. The efficiency of the proposed approach is demonstrated through simulation with the 5MW floating offshore (barge) WT benchmark model given by the aero-lastic wind turbine simulator-FAST. This software is designed by the U.S. National Renewable Energy Laboratory and is widely used in research and industry.Peer ReviewedPostprint (published version
    corecore