    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    LIGHTNING DATA UTILIZATION IN POWER SYSTEM CONTROL

    Get PDF
    Lightning location systems (LLS) provide data on lightning activity such as lightning type, GPS location, exact time of the lightning stroke, lightning current amplitude, measurement error, etc. The proper application of LLS data using customized software support can be a powerful decision-making tool in the control, maintenance and development of power systems. The utilization of lightning data in power systems requires a customized software support with specific functionalities. Software functionalities include real time lightning activity visualization with alarm function; analysis, reports and historical lightning activity visualization; spatial correlation between lightning data and alarm zones around geographically represented power system’s objects (power lines, power facilities, etc.); calculation of lightning statistics; generation of wide area lightning density maps, generation of high resolution lightning density maps inspecting alarm zones around the power lines; real time correlation between lightning activity and the power system protection equipment (distant protection relays), gathered through the SCADA system. In this paper, emphasis will be given to the application in correlation between faults and outages in the power network and lightning strokes. Today, B. Franc, I. Uglešić, S. Piliškić, Lightning data utilization in power system control, Journal of Energy, vol. 64 (2015) Special Issue, p. 62-77 many power companies monitor data related to circuit breaker operation or reclosing using various equipment. Such equipment allows online monitoring of circuit breakers and alarm statuses of equipment in substation

    Partial Discharge Location Technique for Covered-Conductor Overhead Distribution Lines

    Get PDF
    In Finland, covered-conductor (CC) overhead lines are commonly used in medium voltage (MV) networks because the loads are widely distributed in the forested terrain. Such parts of the network are exposed to leaning trees which produce partial discharges (PDs) in CC lines. This thesis presents a technique to locate the PD source on CC overhead distribution line networks. The algorithm is developed and tested using a simulated study and experimental measurements. The Electromagnetic Transient Program-Alternative Transient Program (EMTP-ATP) is used to simulate and analyze a three-phase PD monitoring system, while MATLAB is used for post-processing of the high frequency signals which were measured. A Rogowski coil is used as the measuring sensor. A multi-end correlation-based technique for PD location is implemented using the theory of maximum correlation factor in order to find the time difference of arrival (TDOA) between signal arrivals at three synchronized measuring points. The three stages of signal analysis used are: 1) denoising  by applying discrete wavelet transform (DWT); 2) extracting the PD features using the absolute or windowed standard deviation (STD) and; 3) locating the PD point. The advantage of this technique is the ability to locate the PD source without the need to know the first arrival time and the propagation velocity of the signals. In addition, the faulty section of the CC line between three measuring points can also be identified based on the degrees of correlation. An experimental analysis is performed to evaluate the PD measurement system performance for PD location on CC overhead lines. The measuring set-up is arranged in a high voltage (HV) laboratory. A multi-end measuring method is chosen as a technique to locate the PD source point on the line. A power transformer 110/20 kV was used to energize the AC voltage up to 11.5 kV/phase (20 kV system). The tests were designed to cover different conditions such as offline and online measurements. The thesis evaluates the possibility of using a Rogowski coil for locating faults in MV distribution lines and a test bench of a 20 kV distribution network is developed. Different fault scenarios are simulated including earth and phase faults, arcing faults and faults caused by leaning trees. Results favourably show the possibility of using a Rogowski coil for locating faults in distribution networks.  

    High voltage covered conductor overhead lines: detection of incipient tree faults

    Get PDF
    The aim of this thesis is the study of a new type of high voltage overhead power line, made by means of an insulation layer located around the conductor: these are the covered conductor lines. In particular, the work focuses on the study of the behaviour of these conductors when they get in contact with the vegetation around, which can touch or fall on the line.ope

    Time domain analysis of switching transient fields in high voltage substations

    Get PDF
    Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within the substations. The radiated fields may interfere and disrupt normal operations of electronic equipment used within the substation for measurement, control and communication purposes. Hence there is the need to fully characterise the substation electromagnetic environment as early as the design stage of substation planning and operation to ensure safe operations of the electronic equipment. This paper deals with the computation of transient electromagnetic fields due to switching within a high voltage air-insulated substation (AIS) using the finite difference time domain (FDTD) metho

    Online monitoring and diagnosis of HV cable faults by sheath system currents

    Get PDF

    Subtransmission overhead lines mechanical monitoring for fast detection of damaging events

    Get PDF
    Different harmful events affecting high voltage overhead lines (OHLs) cause changes in the mechanical tension (tensile strength) of conductors. A mechanical monitoring of OHLs, therefore, can provide useful additional information (compared with the information provided by the widely used SCADA systems) about the power system state. The tension measurements combined with a few environmental measurements (air temperature, wind speed) can be used for an automatic (fast) detection of different events and for their approximate location along an OHL, reducing the impact of these events. Referring to 132-150 kV sub-transmission OHLs, this paper proposes some original algorithms, based on the mechanical monitoring of OHLs, for the automatic detection of the following events: conductor breaking, fall of trees on the conductors, ice/snow sleeve accretion on the conductors, strands breaking and galloping. The proposed algorithms require a limited number of sensors placed along the OHLs for measurements of the conductor tension and weather-related quantities

    Synchronized measurement data conditioning and real-time applications

    Get PDF
    Phasor measurement units (PMU), measuring voltage and current phasor with synchronized timestamps, is the fundamental component in wide-area monitoring systems (WAMS) and reveals complex dynamic behaviors of large power systems. The synchronized measurements collected from power grid may degrade due to many factors and impacts of the distorted synchronized measurement data are significant to WAMS. This dissertation focus on developing and improving applications with distorted synchronized measurements from power grid. The contributions of this dissertation are summarized below. In Chapter 2, synchronized frequency measurements of 13 power grids over the world, including both mainland and island systems, are retrieved from Frequency Monitoring Network (FNET/GridEye) and the statistical analysis of the typical power grids are presented. The probability functions of the power grid frequency based on the measurements are calculated and categorized. Developments of generation trip/load shedding and line outage events detection and localization based on high-density PMU measurements are investigated in Chapters 3 and 4 respectively. Four different types of abnormal synchronized measurements are identified from the PMU measurements of a power grid. The impacts of the abnormal synchronized measurements on generation trip/load shedding events detection and localization are evaluated. A line outage localization method based on power flow measurements is proposed to improve the accuracy of line outage events location estimation. A deep learning model is developed to detect abnormal synchronized measurements in Chapter 5. The performance of the model is evaluated with abnormal synchronized measurements from a power grid under normal operation status. Some types of abnormal synchronized measurements in the testing cases are recently observed and reported. An extensive study of hyper-parameters in the model is conducted and evaluation metrics of the model performance are presented. A non-contact synchronized measurements study using electric field strength is investigated in Chapter 6. The theoretical foundation and equation derivations are presented. The calculation process for a single circuit AC transmission line and a double circuit AC transmission line are derived. The derived method is implemented with Matlab and tested in simulation cases

    Novel methods for earth fault passage indication in non-effectively grounded electricity distribution networks

    Get PDF
    Electricity distribution networks are commonly subject to supply interruptions and outages caused by faults. This dissertation focuses on medium voltage distribution networks, which typically consist of primary substations having multiple feeders along which secondary substations are located. When a permanent fault occurs on a segment (the part linking two consecutive secondary substations) of a distribution feeder, the faulted segment needs to be identified and isolated. Identifying the faulted segment can be realized through fault passage indicators. This is a straightforward task when the fault type is a short circuit, as these types of faults involve large currents. However, faulted segment identification for earth faults in non-effectively grounded medium voltage distribution networks has remained a challenge as the earth fault current in those networks is typically relatively small. Therefore, the main objective of this dissertation was to develop novel methods for locating single-phase earth faults in medium voltage distribution networks and validating them through simulations and real system measurements. After comprehensive review of state-of-the-art approaches presented in the literature, the dissertation proposes innovative methods for earth fault passage indication aimed at non-effectively grounded urban or rural distribution networks with radial feeders. The proposed methods are underpinned by a theoretical analysis based on the symmetrical components of the currents on a distribution feeder under an earth fault condition. The comparison of the sequence currents collected from various measuring points on the network forms the backbone of the methods. For practical implementation, current measurements need to be transferred to a central location for processing and decision making, but this can be done without accurate time synchronization. The proposed methods were developed and verified through simulations and empirical data. This work is a product of close collaboration between academia and industry that enabled the validation of the proposed methods with the help of empirical data that was provided by system operators and relay manufacturers. The results obtained from simulations and field tests show the efficacy of utilizing sequence current quantities, in the manner proposed in this work, for identifying the passage of earth faults with fault resistances ranging from zero to several kilo-ohms. In practice, the methods are reliable as long as the current measurements are accurate enough.Sähkönjakeluverkoissa esiintyy vikoja, jotka aiheuttavat sähkönjakelun keskeytyksiä eli sähkökatkoja. Tämä väitöskirja käsittelee keskijänniteverkkoja, jotka koostuvat sähköasemista ja niiltä lähtevistä johtolähdöistä. Johtolähtöjen varrella sijaitsevat pienjänniteverkkoa syöttävät muuntamot. Kun jollain johto-osuudella (tässä ns. muuntamovälillä, joka yhdistää kaksi peräkkäistä muuntamoa) ilmenee pysyvä vika, viallinen johto-osuus on tunnistettava ja erotettava. Viallisen johto-osuuden tunnistaminen tapahtuu vianilmaisimien avulla. Viallisen johto-osuuden tunnistaminen on yksinkertaista, kun vikatyyppi on oikosulku, sillä oikosuluille ominaista ovat yleensä suuret vikavirrat. Haasteena on kuitenkin edelleen viallisten johto-osuuksien tunnistaminen maasulkutilanteissa ei-tehollisesti maadoitetuissa keskijänniteverkoissa, joissa maasulkuvirta on tyypillisesti hyvin pieni. Tämän väitöskirjana tavoitteena on ollut kehittää uusia menetelmiä maasulkuvikojen paikantamiseen keskijänniteverkossa ja varmentaa niiden toimivuus simuloinnein ja todellisesta verkosta saatujen mittausten avulla. Kattavan kirjallisuuskatsauksen jälkeen tässä väitöskirjassa esitellään innovatiivisia menetelmiä vikavirran reitin ilmaisuun jakeluverkkojen maasuluissa. Ehdotetut menetelmät tukeutuvat teoreettiseen analyysiin, jossa johtolähdön virrat maasulkutilanteessa on kuvattu symmetristen komponenttien avulla. Menetelmät perustuvat verkon eri pisteissä mitattuihin virran symmetristen komponenttien vertailuun. Käytännön toteutuksessa nämä mittaukset tulee siirtää keskitettyyn järjestelmään prosessointia ja päätöksentekoa varten, mutta tämä voidaan tehdä ilman tarkkaa aikasynkronointia. Ehdotettujen menetelmien kehittämisessä ja testaamisessa hyödynnettiin simulointeja ja kokeellista mittausdataa. Yhteistyö teollisuuden kanssa mahdollisti menetelmien toiminnan todentamisen hyödyntäen todellisista verkoista mitattua dataa, jota saatiin sekä verkkoyhtiöiltä että laitevalmistajilta. Simulointien tulokset ja mittaukset todellisessa verkossa tehdyistä testeistä osoittavat, että virran symmetriset komponentit toimivat hyvin vian paikannuksessa kun vikaresistanssi on nollan ja muutaman tuhannen ohmin välillä. Käytännössä menetelmien luotettavuus riippuu virran mittauksen tarkkuudesta.fi=vertaisarvioitu|en=peerReviewed