60,013 research outputs found
Multibeam single frequency synthetic aperture radar processor for imaging separate range swaths
A single-frequency multibeam synthetic aperture radar for large swath imaging is disclosed. Each beam illuminates a separate ""footprint'' (i.e., range and azimuth interval). The distinct azimuth intervals for the separate beams produce a distinct Doppler frequency spectrum for each beam. After range correlation of raw data, an optical processor develops image data for the different beams by spatially separating the beams to place each beam of different Doppler frequency spectrum in a different location in the frequency plane as well as the imaging plane of the optical processor. Selection of a beam for imaging may be made in the frequency plane by adjusting the position of an aperture, or in the image plane by adjusting the position of a slit. The raw data may also be processed in digital form in an analogous manner
Characterization of modulated time-of-flight range image sensors
A number of full field image sensors have been developed that are capable of simultaneously measuring intensity and distance (range) for every pixel in a given scene using an indirect time-of-flight measurement technique. A light source is intensity modulated at a frequency between 10–100 MHz, and an image sensor is modulated at the same frequency, synchronously sampling light reflected from objects in the scene (homodyne detection). The time of flight is manifested as a phase shift in the illumination modulation envelope, which can be determined from the sampled data simultaneously for each pixel in the scene. This paper presents a method of characterizing the high frequency modulation response of these image sensors, using a pico-second laser pulser. The characterization results allow the optimal operating parameters, such as the modulation frequency, to be identified in order to maximize the range measurement precision for a given sensor. A number of potential sources of error exist when using these sensors, including deficiencies in the modulation waveform shape, duty cycle, or phase, resulting in contamination of the resultant range data. From the characterization data these parameters can be identified and compensated for by modifying the sensor hardware or through post processing of the acquired range measurements
Time-resolved multi-mass ion imaging: femtosecond UV-VUV pump-probe spectroscopy with the PImMS camera
The Pixel-Imaging Mass Spectrometry (PImMS) camera allows for 3D charged
particle imaging measurements, in which the particle time-of-flight is recorded
along with position. Coupling the PImMS camera to an ultrafast
pump-probe velocity-map imaging spectroscopy apparatus therefore provides a
route to time-resolved multi-mass ion imaging, with both high count rates and
large dynamic range, thus allowing for rapid measurements of complex
photofragmentation dynamics. Furthermore, the use of vacuum ultraviolet
wavelengths for the probe pulse allows for an enhanced observation window for
the study of excited state molecular dynamics in small polyatomic molecules
having relatively high ionization potentials. Herein, preliminary time-resolved
multi-mass imaging results from CFI photolysis are presented. The
experiments utilized femtosecond UV and VUV (160.8~nm and 267~nm) pump and
probe laser pulses in order to demonstrate and explore this new time-resolved
experimental ion imaging configuration. The data indicates the depth and power
of this measurement modality, with a range of photofragments readily observed,
and many indications of complex underlying wavepacket dynamics on the excited
state(s) prepared
Multiple frequency range imaging to remove measurement ambiguity
Range imaging systems use a specialised sensor to capture an image where object distance (range) is measured for every pixel using time-of-flight. The scene is illuminated with an amplitude modulated light source, and the phase of the modulation envelope of the reflected light is measured to determine flight time, hence object distance for each pixel. As the modulation waveform is cyclic, an ambiguity problem exists if the phase shift exceeds 2π radians. To overcome this problem we demonstrate a method that superposes two different modulation frequencies within a single capture. This technique reduces the associated overhead compared with performing two sequential measurements, allowing the system to retain high range measurement precision at rapid acquisition rates. A method is also provided to avoid interference from aliased harmonics during sampling, which otherwise contaminate the resulting range measurement. Experimental results show the potential of the multiple frequency approach; producing high measurement precision while avoiding ambiguity. The results also demonstrate the limitation of this technique, where large errors can be introduced through a combination of a low signal to noise ratio and suboptimal selection of system parameters
Tackling 3D ToF Artifacts Through Learning and the FLAT Dataset
Scene motion, multiple reflections, and sensor noise introduce artifacts in
the depth reconstruction performed by time-of-flight cameras. We propose a
two-stage, deep-learning approach to address all of these sources of artifacts
simultaneously. We also introduce FLAT, a synthetic dataset of 2000 ToF
measurements that capture all of these nonidealities, and allows to simulate
different camera hardware. Using the Kinect 2 camera as a baseline, we show
improved reconstruction errors over state-of-the-art methods, on both simulated
and real data.Comment: ECCV 201
Region-enhanced passive radar imaging
The authors adapt and apply a recently-developed region-enhanced synthetic aperture radar (SAR) image reconstruction technique to the problem of passive radar imaging. One goal in passive radar imaging is to form images of aircraft using signals transmitted by commercial radio and television stations that are reflected from the objects of interest. This involves reconstructing an image from sparse samples of its Fourier transform. Owing to the sparse nature of the aperture, a conventional image formation approach based on direct Fourier transformation results in quite dramatic artefacts in the image, as compared with the case of active SAR imaging. The regionenhanced image formation method considered is based on an explicit mathematical model of the observation process; hence, information about the nature of the aperture is explicitly taken into account in image formation. Furthermore, this framework allows the incorporation of prior information or constraints about the scene being imaged, which makes it possible to compensate for the limitations of the sparse apertures involved in passive radar imaging. As a result, conventional imaging artefacts, such as sidelobes, can be alleviated. Experimental results using data based on electromagnetic simulations demonstrate that this is a promising strategy for passive radar imaging, exhibiting significant suppression of artefacts, preservation of imaged object features, and robustness to measurement noise
Recommended from our members
Time-of-flight resolved light field fluctuations reveal deep human tissue physiology.
Red blood cells (RBCs) transport oxygen to tissues and remove carbon dioxide. Diffuse optical flowmetry (DOF) assesses deep tissue RBC dynamics by measuring coherent fluctuations of multiply scattered near-infrared light intensity. While classical DOF measurements empirically correlate with blood flow, they remain far-removed from light scattering physics and difficult to interpret in layered media. To advance DOF measurements closer to the physics, here we introduce an interferometric technique, surmounting challenges of bulk motion to apply it in awake humans. We reveal two measurement dimensions: optical phase, and time-of-flight (TOF), the latter with 22 picosecond resolution. With this multidimensional data, we directly confirm the unordered, or Brownian, nature of optically probed RBC dynamics typically assumed in classical DOF. We illustrate how incorrect absorption assumptions, anisotropic RBC scattering, and layered tissues may confound classical DOF. By comparison, our direct method enables accurate and comprehensive assessment of blood flow dynamics in humans
- …