319 research outputs found

    Detection of Hemorrhages and Microaneurysms for Color Fundus images: A Review

    Get PDF
    Here we address the study on detection of Hemorrhages and microaneurysms in color fundus images. In pre-Processing we find different separate red, green, blue color channel from the retinal images. The green channel will pass to the further process. The green color plane was used in the analysis since it shows the best contrast between the vessels and the background retina. Then we extract the GLCM(Gray Level Co-Occurance Matrix) feature. We made a survey of different author who have done their work in this field. We also compare the different data mining techniques that are required to perform detection in proper way

    Accurate and reliable segmentation of the optic disc in digital fundus images

    Get PDF
    We describe a complete pipeline for the detection and accurate automatic segmentation of the optic disc in digital fundus images. This procedure provides separation of vascular information and accurate inpainting of vessel-removed images, symmetry-based optic disc localization, and fitting of incrementally complex contour models at increasing resolutions using information related to inpainted images and vessel masks. Validation experiments, performed on a large dataset of images of healthy and pathological eyes, annotated by experts and partially graded with a quality label, demonstrate the good performances of the proposed approach. The method is able to detect the optic disc and trace its contours better than the other systems presented in the literature and tested on the same data. The average error in the obtained contour masks is reasonably close to the interoperator errors and suitable for practical applications. The optic disc segmentation pipeline is currently integrated in a complete software suite for the semiautomatic quantification of retinal vessel properties from fundus camera images (VAMPIRE)

    Detection of Hemorrhages and Microaneurysms for Color Fundus Images

    Get PDF
    Here we address the detection of Hemorrhages and microaneurysms in color fundus images. In pre-Processing we separate red, green, blue color channel from the retinal images. The green channel will pass to the further process. The green color plane was used in the analysis since it shows the best contrast between the vessels and the background retina. Then we extract the GLCM(Gray Level Co-Occurance Matrix) feature. In the GLCMs, several statistics information are derived using the different formulas. These statistics provide information about the texture of an image. Such as Energy, Entropy, Dissimilarity, Contrast, Inverse difference , correlation Homogeneity, Auto correlation, Cluster Shade Cluster Prominence, Maximum probability, Sum of Squares will be calculated for texture image. After feature Extraction, we provide this feature to classifier. Finally it will predict about the retinal whether it is hemorrhages or microaneurysms . After predicting the about the retinal image we will localize the affected place. For segmenting the localized place we will use adaptive thresholding segmentation

    Digital ocular fundus imaging: a review

    Get PDF
    Ocular fundus imaging plays a key role in monitoring the health status of the human eye. Currently, a large number of imaging modalities allow the assessment and/or quantification of ocular changes from a healthy status. This review focuses on the main digital fundus imaging modality, color fundus photography, with a brief overview of complementary techniques, such as fluorescein angiography. While focusing on two-dimensional color fundus photography, the authors address the evolution from nondigital to digital imaging and its impact on diagnosis. They also compare several studies performed along the transitional path of this technology. Retinal image processing and analysis, automated disease detection and identification of the stage of diabetic retinopathy (DR) are addressed as well. The authors emphasize the problems of image segmentation, focusing on the major landmark structures of the ocular fundus: the vascular network, optic disk and the fovea. Several proposed approaches for the automatic detection of signs of disease onset and progression, such as microaneurysms, are surveyed. A thorough comparison is conducted among different studies with regard to the number of eyes/subjects, imaging modality, fundus camera used, field of view and image resolution to identify the large variation in characteristics from one study to another. Similarly, the main features of the proposed classifications and algorithms for the automatic detection of DR are compared, thereby addressing computer-aided diagnosis and computer-aided detection for use in screening programs.Fundação para a Ciência e TecnologiaFEDErPrograma COMPET

    Automatic analysis of retinal images to aid in the diagnosis and grading of diabetic retinopathy

    Get PDF
    Diabetic retinopathy (DR) is the most common complication of diabetes mellitus and one of the leading causes of preventable blindness in the adult working population. Visual loss can be prevented from the early stages of DR, when the treatments are effective. Therefore, early diagnosis is paramount. However, DR may be clinically asymptomatic until the advanced stage, when vision is already affected and treatment may become difficult. For this reason, diabetic patients should undergo regular eye examinations through screening programs. Traditionally, DR screening programs are run by trained specialists through visual inspection of the retinal images. However, this manual analysis is time consuming and expensive. With the increasing incidence of diabetes and the limited number of clinicians and sanitary resources, the early detection of DR becomes non-viable. For this reason, computed-aided diagnosis (CAD) systems are required to assist specialists for a fast, reliable diagnosis, allowing to reduce the workload and the associated costs. We hypothesize that the application of novel, automatic algorithms for fundus image analysis could contribute to the early diagnosis of DR. Consequently, the main objective of the present Doctoral Thesis is to study, design and develop novel methods based on the automatic analysis of fundus images to aid in the screening, diagnosis, and treatment of DR. In order to achieve the main goal, we built a private database and used five retinal public databases: DRIMDB, DIARETDB1, DRIVE, Messidor and Kaggle. The stages of fundus image processing covered in this Thesis are: retinal image quality assessment (RIQA), the location of the optic disc (OD) and the fovea, the segmentation of RLs and EXs, and the DR severity grading. RIQA was studied with two different approaches. The first approach was based on the combination of novel, global features. Results achieved 91.46% accuracy, 92.04% sensitivity, and 87.92% specificity using the private database. We developed a second approach aimed at RIQA based on deep learning. We achieved 95.29% accuracy with the private database and 99.48% accuracy with the DRIMDB database. The location of the OD and the fovea was performed using a combination of saliency maps. The proposed methods were evaluated over the private database and the public databases DRIVE, DIARETDB1 and Messidor. For the OD, we achieved 100% accuracy for all databases except Messidor (99.50%). As for the fovea location, we also reached 100% accuracy for all databases except Messidor (99.67%). The joint segmentation of RLs and EXs was accomplished by decomposing the fundus image into layers. Results were computed per pixel and per image. Using the private database, 88.34% per-image accuracy (ACCi) was reached for the RL detection and 95.41% ACCi for EX detection. An additional method was proposed for the segmentation of RLs based on superpixels. Evaluating this method with the private database, we obtained 84.45% ACCi. Results were validated using the DIARETDB1 database. Finally, we proposed a deep learning framework for the automatic DR severity grading. The method was based on a novel attention mechanism which performs a separate attention of the dark and the bright structures of the retina. The Kaggle DR detection dataset was used for development and validation. The International Clinical DR Scale was considered, which is made up of 5 DR severity levels. Classification results for all classes achieved 83.70% accuracy and a Quadratic Weighted Kappa of 0.78. The methods proposed in this Doctoral Thesis form a complete, automatic DR screening system, contributing to aid in the early detection of DR. In this way, diabetic patients could receive better attention for their ocular health avoiding vision loss. In addition, the workload of specialists could be relieved while healthcare costs are reduced.La retinopatía diabética (RD) es la complicación más común de la diabetes mellitus y una de las principales causas de ceguera prevenible en la población activa adulta. El diagnóstico precoz es primordial para prevenir la pérdida visual. Sin embargo, la RD es clínicamente asintomática hasta etapas avanzadas, cuando la visión ya está afectada. Por eso, los pacientes diabéticos deben someterse a exámenes oftalmológicos periódicos a través de programas de cribado. Tradicionalmente, estos programas están a cargo de especialistas y se basan de la inspección visual de retinografías. Sin embargo, este análisis manual requiere mucho tiempo y es costoso. Con la creciente incidencia de la diabetes y la escasez de recursos sanitarios, la detección precoz de la RD se hace inviable. Por esta razón, se necesitan sistemas de diagnóstico asistido por ordenador (CAD) que ayuden a los especialistas a realizar un diagnóstico rápido y fiable, que permita reducir la carga de trabajo y los costes asociados. El objetivo principal de la presente Tesis Doctoral es estudiar, diseñar y desarrollar nuevos métodos basados en el análisis automático de retinografías para ayudar en el cribado, diagnóstico y tratamiento de la RD. Las etapas estudiadas fueron: la evaluación de la calidad de la imagen retiniana (RIQA), la localización del disco óptico (OD) y la fóvea, la segmentación de RL y EX y la graduación de la severidad de la RD. RIQA se estudió con dos enfoques diferentes. El primer enfoque se basó en la combinación de características globales. Los resultados lograron una precisión del 91,46% utilizando la base de datos privada. El segundo enfoque se basó en aprendizaje profundo. Logramos un 95,29% de precisión con la base de datos privada y un 99,48% con la base de datos DRIMDB. La localización del OD y la fóvea se realizó mediante una combinación de mapas de saliencia. Los métodos propuestos fueron evaluados sobre la base de datos privada y las bases de datos públicas DRIVE, DIARETDB1 y Messidor. Para el OD, logramos una precisión del 100% para todas las bases de datos excepto Messidor (99,50%). En cuanto a la ubicación de la fóvea, también alcanzamos un 100% de precisión para todas las bases de datos excepto Messidor (99,67%). La segmentación conjunta de RL y EX se logró descomponiendo la imagen del fondo de ojo en capas. Utilizando la base de datos privada, se alcanzó un 88,34% de precisión por imagen (ACCi) para la detección de RL y un 95,41% de ACCi para la detección de EX. Se propuso un método adicional para la segmentación de RL basado en superpíxeles. Evaluando este método con la base de datos privada, obtuvimos 84.45% ACCi. Los resultados se validaron utilizando la base de datos DIARETDB1. Finalmente, propusimos un método de aprendizaje profundo para la graduación automática de la gravedad de la DR. El método se basó en un mecanismo de atención. Se utilizó la base de datos Kaggle y la Escala Clínica Internacional de RD (5 niveles de severidad). Los resultados de clasificación para todas las clases alcanzaron una precisión del 83,70% y un Kappa ponderado cuadrático de 0,78. Los métodos propuestos en esta Tesis Doctoral forman un sistema completo y automático de cribado de RD, contribuyendo a ayudar en la detección precoz de la RD. De esta forma, los pacientes diabéticos podrían recibir una mejor atención para su salud ocular evitando la pérdida de visión. Además, se podría aliviar la carga de trabajo de los especialistas al mismo tiempo que se reducen los costes sanitarios.Escuela de DoctoradoDoctorado en Tecnologías de la Información y las Telecomunicacione
    corecore