111 research outputs found

    3D reconstruction of ribcage geometry from biplanar radiographs using a statistical parametric model approach

    Get PDF
    Rib cage 3D reconstruction is an important prerequisite for thoracic spine modelling, particularly for studies of the deformed thorax in adolescent idiopathic scoliosis. This study proposes a new method for rib cage 3D reconstruction from biplanar radiographs, using a statistical parametric model approach. Simplified parametric models were defined at the hierarchical levels of rib cage surface, rib midline and rib surface, and applied on a database of 86 trunks. The resulting parameter database served to statistical models learning which were used to quickly provide a first estimate of the reconstruction from identifications on both radiographs. This solution was then refined by manual adjustments in order to improve the matching between model and image. Accuracy was assessed by comparison with 29 rib cages from CT scans in terms of geometrical parameter differences and in terms of line-to-line error distance between the rib midlines. Intra and inter-observer reproducibility were determined regarding 20 scoliotic patients. The first estimate (mean reconstruction time of 2’30) was sufficient to extract the main rib cage global parameters with a 95% confidence interval lower than 7%, 8%, 2% and 4° for rib cage volume, antero-posterior and lateral maximal diameters and maximal rib hump, respectively. The mean error distance was 5.4 mm (max 35mm) down to 3.6 mm (max 24 mm) after the manual adjustment step (+3’30). The proposed method will improve developments of rib cage finite element modeling and evaluation of clinical outcomes.This work was funded by Paris Tech BiomecAM chair on subject specific muscular skeletal modeling, and we express our acknowledgments to the chair founders: Cotrel foundation, Société générale, Protéor Company and COVEA consortium. We extend your acknowledgements to Alina Badina for medical imaging data, Alexandre Journé for his advices, and Thomas Joubert for his technical support

    Rib Cage Measurement Reproducibility Using Biplanar Stereoradiographic 3D Reconstructions in Adolescent Idiopathic Scoliosis

    Get PDF
    Study design: A reproducibility study of preoperative rib cage 3D measurements was conducted for patients with Adolescent Idiopathic Scoliosis (AIS). Objective: to assess the reliability of rib cage 3D reconstructions using biplanar stereoradiography in patients with AIS before surgery. Summary: no prior reliability study has been performed for preoperative 3D reconstructions of the rib cage by using stereoradiography in patients with preoperative AIS. Materials: this series includes 21 patients with Lenke 1 or 2 scoliosis (74°+ - 20). All patients underwent low-dose standing biplanar radiographs. Two operators performed reconstructions twice each. Intraoperator repeatability, interoperator reproducibility and Intraclass coefficients (ICC) were calculated and compared between groups. Results: The average rib cage volume was 4.7l L (SD ± 0.75 L). SDr was 0.19 L with a coefficient of variation of 4.1% ; ICC was 0.968. The thoracic index was 0.6 (SD ± 0.1). SDr was 0.03 with a coefficient of variation of 4.7 % and a ICC of 0.820. As for the Spinal Penetration Index (6.4% ; SD ± 2.4), SDr was 0.9 % with a coefficient of variation of 14.3 % and a ICC of 0.901. The 3D rib hump SDr (average 27° ± 8°) was 1.4°. The coefficient of variation and ICC were respectively 5.1% and 0.991. Conclusion: 3D reconstruction of the rib cage using biplanar stereoradiography is a reliable method to estimate preoperative thoracic parameters in patients with AIS

    Personalized 3D reconstruction of the rib cage for clinical assessment of trunk deformities

    Get PDF
    Scoliosis is a 3D deformity of the spine and rib cage. Extensive validation of 3D reconstruction methods of the spine from biplanar radiography has already been published. In this article, we propose a novel method to reconstruct the rib cage, using the same biplanar views as for the 3D reconstruction of the spine, to allow clinical assessment of whole trunk deformities. This technique uses a semi-automatic segmentation of the ribs in the postero-anterior X-ray view and an interactive segmentation of partial rib edges in the lateral view. The rib midlines are automatically extracted in 2D and reconstructed in 3D using the epipolar geometry. For the ribs not visible in the lateral view, the method predicts their 3D shape. The accuracy of the proposed method has been assessed using data obtained from a synthetic bone model as a gold standard and has also been evaluated using data of real patients with scoliotic deformities. Results show that the reconstructed ribs enable a reliable evaluation of the rib axial rotation, which will allow a 3D clinical assessment of the spine and rib cage deformities.CIHR / IRS

    Biomechanical Morphing for Personalized Fitting of Scoliotic Torso Skeleton Models

    Get PDF
    The use of patient-specific biomechanical models offers many opportunities in the treatment of adolescent idiopathic scoliosis, such as the design of personalized braces. The first step in the development of these patient-specific models is to fit the geometry of the torso skeleton to the patient’s anatomy. However, existing methods rely on high-quality imaging data. The exposure to radiation of these methods limits their applicability for regular monitoring of patients. We present a method to fit personalized models of the torso skeleton that takes as input biplanar low-dose radiographs. The method morphs a template to fit annotated points on visible portions of the spine, and it relies on a default biomechanical model of the torso for regularization and robust fitting of hardly visible parts of the torso skeleton, such as the rib cage. The proposed method provides an accurate and robust solution to obtain personalized models of the torso skeleton, which can be adopted as part of regular management of scoliosis patients. We have evaluated the method on ten young patients who participated in our study. We have analyzed and compared clinical metrics on the spine and the full torso skeleton, and we have found that the accuracy of the method is at least comparable to other methods that require more demanding imaging methods, while it offers superior robustness to artifacts such as interpenetration of ribs. Normal-dose X-rays were available for one of the patients, and for the other nine we acquired low-dose X-rays, allowing us to validate that the accuracy of the method persisted under less invasive imaging modalities

    Evaluation of a patient-specific finite-element model to simulate conservative treatment in adolescent idiopathic scoliosis

    Get PDF
    PublishedJournal ArticleAuthor's accepted manuscript.Study design: Retrospective validation study. Objectives: To propose a method to evaluate, from a clinical standpoint, the ability of a finite-element model (FEM) of the trunk to simulate orthotic correction of spinal deformity and to apply it to validate a previously described FEM. Summary of background data: Several FEMs of the scoliotic spine have been described in the literature. These models can prove useful in understanding the mechanisms of scoliosis progression and in optimizing its treatment, but their validation has often been lacking or incomplete. Methods: Three-dimensional (3D) geometries of 10 patients before and during conservative treatment were reconstructed from biplanar radiographs. The effect of bracing was simulated by modeling displacements induced by the brace pads. Simulated clinical indices (Cobb angle, T1-T12 and T4-T12 kyphosis, L1-L5 lordosis, apical vertebral rotation, torsion, rib hump) and vertebral orientations and positions were compared to those measured in the patients' 3D geometries. Results: Errors in clinical indices were of the same order of magnitude as the uncertainties due to 3D reconstruction; for instance, Cobb angle was simulated with a root mean square error of 5.7°, and rib hump error was 5.6°. Vertebral orientation was simulated with a root mean square error of 4.8° and vertebral position with an error of 2.5 mm. Conclusions: The methodology proposed here allowed in-depth evaluation of subject-specific simulations, confirming that FEMs of the trunk have the potential to accurately simulate brace action. These promising results provide a basis for ongoing 3D model development, toward the design of more efficient orthoses.ParisTech BiomecAM chair programProteorParisTechYves Cotrel Foundation

    A Novel Method for the 3-D Reconstruction of Scoliotic Ribs From Frontal and Lateral Radiographs

    Get PDF
    Among the external manifestations of scoliosis, the rib hump, which is associated with the ribs' deformities and rotations, constitutes the most disturbing aspect of the scoliotic deformity for patients. A personalized 3-D model of the rib cage is important for a better evaluation of the deformity, and hence, a better treatment planning. A novel method for the 3-D reconstruction of the rib cage, based only on two standard radiographs, is proposed in this paper. For each rib, two points are extrapolated from the reconstructed spine, and three points are reconstructed by stereo radiography. The reconstruction is then refined using a surface approximation. The method was evaluated using clinical data of 13 patients with scoliosis. A comparison was conducted between the reconstructions obtained with the proposed method and those obtained by using a previous reconstruction method based on two frontal radiographs. A first comparison criterion was the distances between the reconstructed ribs and the surface topography of the trunk, considered as the reference modality. The correlation between ribs axial rotation and back surface rotation was also evaluated. The proposed method successfully reconstructed the ribs of the 6th-12th thoracic levels. The evaluation results showed that the 3-D configuration of the new rib reconstructions is more consistent with the surface topography and provides more accurate measurements of ribs axial rotation.Natural Sciences and Engineering Research Council of Canada and MENTOR, a strategic training program of the Canadian Institutes of Health Research

    Quantitative geometric analysis of rib, costal cartilage and sternum from childhood to teenagehood

    Get PDF
    Better understanding of the effects of growth on children’s bones and cartilage is necessary for clinical and biomechanical purposes. The aim of this study is to define the 3D geometry of children’s rib cages: including sternum, ribs and costal cartilage. Three-dimensional reconstructions of 960 ribs, 518 costal cartilages and 113 sternebrae were performed on thoracic CT-scans of 48 children, aged four months to 15 years. The geometry of the sternum was detailed and nine parameters were used to describe the ribs and rib cages. A "costal index" was defined as the ratio between cartilage length and whole rib length to evaluate the cartilage ratio for each rib level. For all children, the costal index decreased from rib level one to three and increased from level three to seven. For all levels, the cartilage accounted for 45 to 60% of the rib length, and was longer for the first years of life. The mean costal index decreased by 21% for subjects over three years old compared to those under three (p<10-4). The volume of the sternebrae was found to be highly age dependent. Such data could be useful to define the standard geometry of the paediatric thorax and help to detect clinical abnormalities.Grant from the ANR (SECUR_ENFANT 06_0385) and supported by the GDR 2610 “Biomécanique des chocs” (CNRS/INRETS/GIE PSA Renault

    Rib Cage Measurement Reproducibility Using Biplanar Stereoradiographic 3D Reconstructions in Adolescent Idiopathic Scoliosis

    Get PDF
    Study design: A reproducibility study of preoperative rib cage 3D measurements was conducted for patients with Adolescent Idiopathic Scoliosis (AIS). Objective: to assess the reliability of rib cage 3D reconstructions using biplanar stereoradiography in patients with AIS before surgery. Summary: no prior reliability study has been performed for preoperative 3D reconstructions of the rib cage by using stereoradiography in patients with preoperative AIS. Materials: this series includes 21 patients with Lenke 1 or 2 scoliosis (74°+ - 20). All patients underwent low-dose standing biplanar radiographs. Two operators performed reconstructions twice each. Intraoperator repeatability, interoperator reproducibility and Intraclass coefficients (ICC) were calculated and compared between groups. Results: The average rib cage volume was 4.7l L (SD ± 0.75 L). SDr was 0.19 L with a coefficient of variation of 4.1% ; ICC was 0.968. The thoracic index was 0.6 (SD ± 0.1). SDr was 0.03 with a coefficient of variation of 4.7 % and a ICC of 0.820. As for the Spinal Penetration Index (6.4% ; SD ± 2.4), SDr was 0.9 % with a coefficient of variation of 14.3 % and a ICC of 0.901. The 3D rib hump SDr (average 27° ± 8°) was 1.4°. The coefficient of variation and ICC were respectively 5.1% and 0.991. Conclusion: 3D reconstruction of the rib cage using biplanar stereoradiography is a reliable method to estimate preoperative thoracic parameters in patients with AIS

    A novel method of anatomical landmark selection for rib cage 3D reconstruction from biplanar radiography

    Get PDF
    Methods to reconstruct anatomical structures in 3D are gaining interest in medicine because they give access to quantitative information on the patient’s geometry. However, these methods are user-dependent and require a trained operator, which is time consuming and a source of error and unreliability. The aim of this work was to validate a novel method of landmark selection to perform the 3D reconstruction of the rib cage from biplanar calibrated radiographies. The method uses digital painting for digitization of anatomical landmarks (eight ribs midlines, posterior extrema, sternum) to build a first estimate of the 3D ribcage geometry. Twenty scoliotic patients were included (Cobb angle: 43° ± 11°) and their ribcage was reconstructed twice with the proposed method by four trained operators. Measurement reproducibility was similar to previously validated methods. Uncertainty (95% CI) was 2.3° for the rib hump measurement, 9.7 mm and 3.8 mm for maximal antero-posterior and lateral diameter, 395 cm3 for ribcage volume. The method was qualitatively considered more user-friendly than previous versions, although it still requires a trained operator, and it took approximately 2 minutes of manual digitization. The new method should facilitate diffusion of 3D quantitative analysis of ribcage in clinical routine
    • …
    corecore