Screening of energy efficient technologies for industrial buildings' retrofit
This chapter discusses screening of energy efficient technologies for industrial buildings' retrofit
Coupled TRNSYS-CFD simulations evaluating the performance of PCM plate heat exchangers in an Airport Terminal building displacement conditioning system
This is the post-print version of the Article. The official published version can be accessed from the link below. Copyright @ 2013 Elsevier.This paper reports on the energy performance evaluation of a displacement ventilation (DV) system in an airport departure hall, with a conventional DV diffuser and a diffuser retrofitted with a phase change material storage heat exchanger (PCM-HX). A TRNSYS-CFD quasi-dynamic coupled simulation method was employed for the analysis, whereby TRNSYS® simulates the HVAC and PID control system and ANSYS FLUENT® is used to simulate the airflow inside the airport terminal space. The PCM-HX is also simulated in CFD, and is integrated into the overall model as a secondary coupled component in the TRNSYS interface. Different night charging strategies of the PCM-HX were investigated and compared with the conventional DV diffuser. The results show that: i) the displacement ventilation system is more efficient for cooling than heating a space; ii) the addition of a PCM-HX system reduces the heating energy requirements during the intermediate and summer periods for specific night charging strategies, whereas winter heating energy remains unaffected; iii) the PCM-HX reduces cooling energy requirements, and; iv) maximum energy savings of 34% are possible with the deployment of PCM-HX retrofitted DV diffuser.This work was funded by the UK Engineering and Physical Sciences Research Council (EPSRC), Grant No: EP/H004181/1
History and development of validation with the ESP-r simulation program
It is well recognised that validation of dynamic building simulation programs is a long-term complex task. There have been many large national and international efforts that have led to a well-established validation methodology comprising analytical, inter-program comparison and empirical validation elements, and a significant number of tests have been developed. As simulation usage increases, driven by such initiatives as the European Energy Performance of Buildings Directive, such tests are starting to be incorporated into national and international standards. Although many program developers have run many of the developed tests, there does not appear to have been a systematic attempt to incorporate such tests into routine operation of the simulation programs. This paper reports work undertaken to address this deficiency. The paper summarizes the tests that have been applied to the simulation program ESP-r. These tests have been developed within International Energy Agency Annexes, within CEN standards, within various large-scale national projects, and by the UK's Chartered Institution of Building Services Engineers. The structure used to encapsulate the tests allows developers to ensure that recent code modifications have not resulted in unforeseen impacts on program predictions, and allows users to check for themselves against benchmarks
Heat removal efficiency of stratum ventilation for air-side modulation
Stratum ventilation has significant thermal non-uniformity between the occupied and upper zones. Although the non-uniformity benefits indoor air quality and energy efficiency, it increases complexities and difficulties in the air-side modulation. In this study, a heat removal efficiency (HRE) model is first established and validated, and then used for the air-side modulation. The HRE model proposed is a function of supply air temperature, supply airflow rate and cooling load. The HRE model proposed has been proven to be applicable to stratum ventilation and displacement ventilation for different room geometries and air terminal configurations, with errors generally within ±5% and a mean absolute error less than 4% for thirty-three experimental cases and five simulated cases. Investigations into the air-side modulation with the proposed HRE model reveal that for both the typical stratum-ventilated classroom and office, the variable-air-volume system can serve a wider range of cooling load than the constant-air-volume system. The assumption of a constant HRE used in the conventional method could lead to errors in the room temperature prediction up to ±1.3 °C, thus the proposed HRE model is important to the air-side modulation for thermal comfort. An air-side modulation method is proposed based on the HRE model to maximize the HRE for improving energy efficiency while maintaining thermal comfort. Results show that the HRE model based air-side modulation can improve the energy efficiency of stratum ventilation up to 67.3%. The HRE model based air-side modulation is also promising for displacement ventilation
Recommended from our members
High-Performance Integrated Window and Façade Solutions for California
The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California
Recommended from our members
Providing Grid Services With Heat Pumps: A Review
Abstract
The integration of variable and intermittent renewable energy generation into the power system is a grand challenge to our efforts to achieve a sustainable future. Flexible demand is one solution to this challenge, where the demand can be controlled to follow energy supply, rather than the conventional way of controlling energy supply to follow demand. Recent research has shown that electric building climate control systems like heat pumps can provide this demand flexibility by effectively storing energy as heat in the thermal mass of the building. While some forms of heat pump demand flexibility have been implemented in the form of peak pricing and utility demand response programs, controlling heat pumps to provide ancillary services like frequency regulation, load following, and reserve have yet to be widely implemented. In this paper, we review the recent advances and remaining challenges in controlling heat pumps to provide these grid services. This analysis includes heat pump and building modeling, control methods both for isolated heat pumps and heat pumps in aggregate, and the potential implications that this concept has on the power system
Recommended from our members
Provision of secondary frequency regulation by coordinated dispatch of industrial loads and thermal power plants
Demand responsive industrial loads with high thermal inertia have potential to provide ancillary service for frequency regulation in the power market. To capture the benefit, this study proposes a new hierarchical framework to coordinate the demand responsive industrial loads with thermal power plants in an industrial park for secondary frequency control. In the proposed framework, demand responsive loads and generating resources are coordinated for optimal dispatch in two-time scales: (1) the regulation reserve of the industrial park is optimally scheduled in a day-ahead manner. The stochastic regulation signal is replaced by the specific extremely trajectories. Furthermore, the extremely trajectories are achieved by the day-ahead predicted regulation mileage. The resulting benefit is to transform the stochastic reserve scheduling problem into a deterministic optimization; (2) a model predictive control strategy is proposed to dispatch the industry park in real time with an objective to maximize the revenue. The proposed technology is tested using a real-world industrial electrolysis power system based upon Pennsylvania, Jersey, and Maryland (PJM) power market. Various scenarios are simulated to study the performance of the proposed approach to enable industry parks to provide ancillary service into the power market. The simulation results indicate that an industrial park with a capacity of 500 MW can provide up to 40 MW ancillary service for participation in the secondary frequency regulation. The proposed strategy is demonstrated to be capable of maintaining the economic and secure operation of the industrial park while satisfying performance requirements from the real world regulation market
Energy-efficient HVAC systems: Simulation-empirical modelling and gradient optimization
This paper addresses the energy saving problem of air-cooled central cooling plant systems using the model-based gradient projection optimization method. Theoretical-empirical system models including mechanistic relations between components are developed for operating variables of the system. Experimental data are collected to model an actual air-cooled mini chiller equipped with a ducted fan-coil unit of an office building located in hot and dry climate conditions. Both inputs and outputs are known and measured from field monitoring in one summer month. The development and algorithm resulting from the gradient projection, implemented on a transient simulation software package, are incorporated to solve the minimization problem of energy consumption and predict the system's optimal set-points under transient conditions. The chilled water temperature, supply air temperature and refrigerant mass flow rate are calculated based on the cooling load and ambient dry-bulb temperature profiles by using the proposed approach. The integrated simulation tool is validated by using a wide range of experimentally collected data from the chiller in operation. Simulation results are provided to show possibility of significant energy savings and comfort enhancement using the proposed strategy. © 2012 Elsevier B.V
Contribution To The Development Of A New Integrated Zonal Modeling Approach In Building Environment
Various modeling approaches have been developed and applied to predict the heat and mass transfer phenomena within buildings. In consideration of the complexity of the phenomena observed, the results expected, the parameters investigated, and the degree of accuracy required, these modeling approaches can be categorized into three groups: Single-zone (and multi-zone) models, Zonal models, and Computational Fluid Dynamics (CFD) models. Zonal models, which combine the simplicity of single/multi-zone models with the comprehensiveness of CFD models, become better substitutes to predict detailed indoor thermal and airflow behaviors. Based on a geometrical partition of a room into a number of subzones, zonal models can provide more accurate and detailed results than single/multi-zone models and use less computer resources than CFD models. In this work, firstly, a comprehensive building thermal modeling approach has been developed by integrating the zonal model, Pressurized zOnal Model with the Air diffuser (POMA), with a building multi-zone thermal model, in order to improve the prediction aptitudes of the model used in building environment, in terms of accuracy and comprehensiveness. Secondly, this developed integrated thermal model has been used for various building systems and applications, such as the estimation of building load and/or energy saving, the determination of the appropriate set point and position of room thermostat, and the prediction of indoor thermal comfort levels. In these applications, two systems have been considered, the UnderFloor Air Distribution (UFAD) system and the general heating system. Distinct advantages of this developed model over the conventional single/multi-zone thermal modeling approach have been demonstrated
- …