77 research outputs found

    Thick film PZT transducer arrays for particle manipulation

    Get PDF
    This paper reports the fabrication and evaluation of a two-dimensional thick film PZT ultrasonic transducer array operating at about 7.5 MHz for particle manipulation. All layers on the array are screen-printed and sintered on an Al2O3 substrate without further processes or patterning. The measured dielectric constant of the PZT is 2250 ± 100, and the dielectric loss is 0.09 ± 0.005 at 10 kHz. Finite element analysis has been used to predict the behaviour of the array and impedance spectroscopy and laser vibrometry have been used to characterise its performance. The measured deflection of a single activate element is on the order of tens of nanometres with 20 Vpp input. Particle manipulation experiments have been performed by coupling the thick film array to a capillary containing polystyrene microspheres in water

    Investigating the motility of Dictyostelium discodeum using high frequency ultrasound as a method of manipulation

    Get PDF
    Cell motility is an essential process in the development of all organisms. The earliest stages of embryonic development involve massive reconfigurations of groups of cells to form the early body structures. Embryos are very complex systems, and therefore to investigate the molecular and cellular basis of development a simpler genetically tractable model system is used. The social amoeba Dictyostelium Discoideum is known to chemotax up a chemical gradient. From previous work, it is clear that cells generate forces in the nN range. This is above the limit of optical tweezers and therefore we are investigating the use of acoustic tweezers instead. In this paper, we present recent progress of the investigation in to the use of acoustic tweezers for the characterisation of cell motility and forces. We will describe the design, modelling and fabrication of several devices. All devices use high frequency (>15MHz) ultrasound to exert a force on the cells to position and/or stall them. Also, each device is designed to be suitable for the life-sciences laboratory where form-factor and sterility is concerned. A transducer (LiNo) operating at 24 MHz excites resonant acoustic modes in a rectangular glass capillary (100um by 2mm). This device is used to alter the directionality of the motile cells inside the fluid filled capillary. A quarter-ring PZT26 transducer operating at 20.5MHz is shown to be useful for manipulating cells using axial acoustic radiation forces. This device is used to exert a force on cells and shown to pull them away from a coverslip. The presented devices show promise for the manipulation of cells in suspension. Currently the forces produced are below that required for adherent cells; the reasons for this are discussed. We also report on other issues that arise when using acoustic waves for manipulating biological samples such as streaming and heating

    Development of a 1D phased ultrasonic array for intravascular sonoporation

    Get PDF
    Error on title page – year of award is 2021.Sonoporation represents a promising approach to increase targeted drug delivery efficiency by facilitating transport of therapeutic agents to the target tissue with the use of ultrasound. However, most of the current research in sonoporation is performed with external ultrasonic transducers, which hinders the applicability of the therapeutic procedure for treatment of conditions situated deeper into the patient’s body, such as liver or intestinal tumours. This Thesis presents the development process of a miniature-sized 1-3 connectivity piezocomposite 1D phased array for intracorporeal sonoporation. The device was to be incorporated into a capsule or catheter and hence the primary design constraint was the reduced size of the piezoelectric element, which was limited to 2.5 mm in width and 12 mm in length. To meet the needs of the intended application, resonance frequencies of 1.5 MHz and 3.0 MHz were considered. A simulation framework was developed for optimization of the miniature array in relation to the peak negative pressure attained at the focus to mitigate the low power output associated with the limited device dimensions. This was implemented through a multiparametric sweep of the 1-3 piezocomposite geometry-related parameters. Devices made with PZT-5H and PMN-29%PT were evaluated. The optimization algorithm was used to determine specifications for phased array designs based on the two materials and the two resonance frequencies. The 1.5 MHz devices comprised 24 elements and the 3.0 MHz ones had 32 elements. The piezocomposites were manufactured using the dice and fill technique and electroded using a novel method of electrode deposition employing spin coating of Ag ink. Subsequently, the prototype devices were driven with a commercial array controller and characterized with a calibrated needle hydrophone in a scanning tank. Two simulation profiles based on finite element analysis and time extrapolation were developed to model the acoustic beams from the arrays, which were compared and calibrated with experimental data for focal distances between 5 mm and 10 mm and beam steering angles from 0° to 40°. The results showed that modelling could be employed reliably for therapeutic planning. Both the 1.5 MHz and the 3.0 MHz, PZT-5H arrays were tested in vitro and shown to induce and control sonoporation of a human epithelial colorectal adenocarcinoma cell layer. Finally, a 24 element, 1.5 MHz, PZT-5H array was implemented in a 40 mm long by 11 mm diameter tethered, biocompatible capsule intended for in vivo operation. The device was characterized in the scanning tank for steering angles in the range 0° to 56° and focal distances between 4.0 mm and 5.7 mm, and the measured beam profiles were correlated with the simulation framework. The capsule will be tested in future ex-vivo and in-vivo experiments on insulin absorption through porcine small bowel by means of sonoporation.Sonoporation represents a promising approach to increase targeted drug delivery efficiency by facilitating transport of therapeutic agents to the target tissue with the use of ultrasound. However, most of the current research in sonoporation is performed with external ultrasonic transducers, which hinders the applicability of the therapeutic procedure for treatment of conditions situated deeper into the patient’s body, such as liver or intestinal tumours. This Thesis presents the development process of a miniature-sized 1-3 connectivity piezocomposite 1D phased array for intracorporeal sonoporation. The device was to be incorporated into a capsule or catheter and hence the primary design constraint was the reduced size of the piezoelectric element, which was limited to 2.5 mm in width and 12 mm in length. To meet the needs of the intended application, resonance frequencies of 1.5 MHz and 3.0 MHz were considered. A simulation framework was developed for optimization of the miniature array in relation to the peak negative pressure attained at the focus to mitigate the low power output associated with the limited device dimensions. This was implemented through a multiparametric sweep of the 1-3 piezocomposite geometry-related parameters. Devices made with PZT-5H and PMN-29%PT were evaluated. The optimization algorithm was used to determine specifications for phased array designs based on the two materials and the two resonance frequencies. The 1.5 MHz devices comprised 24 elements and the 3.0 MHz ones had 32 elements. The piezocomposites were manufactured using the dice and fill technique and electroded using a novel method of electrode deposition employing spin coating of Ag ink. Subsequently, the prototype devices were driven with a commercial array controller and characterized with a calibrated needle hydrophone in a scanning tank. Two simulation profiles based on finite element analysis and time extrapolation were developed to model the acoustic beams from the arrays, which were compared and calibrated with experimental data for focal distances between 5 mm and 10 mm and beam steering angles from 0° to 40°. The results showed that modelling could be employed reliably for therapeutic planning. Both the 1.5 MHz and the 3.0 MHz, PZT-5H arrays were tested in vitro and shown to induce and control sonoporation of a human epithelial colorectal adenocarcinoma cell layer. Finally, a 24 element, 1.5 MHz, PZT-5H array was implemented in a 40 mm long by 11 mm diameter tethered, biocompatible capsule intended for in vivo operation. The device was characterized in the scanning tank for steering angles in the range 0° to 56° and focal distances between 4.0 mm and 5.7 mm, and the measured beam profiles were correlated with the simulation framework. The capsule will be tested in future ex-vivo and in-vivo experiments on insulin absorption through porcine small bowel by means of sonoporation

    Nonlinear acoustics in ultrasound metrology and other selected applications

    Get PDF
    AbstractA succinct background explaining why, initially, both the scientific community and industry were skeptical about the existence of the nonlinear (NL) wave propagation in tissue will be given and the design of an adequately wideband piezoelectric polymer hydrophone probe that was eventually used to verify that the 1–5 MHz probing wave then used in diagnostic ultrasound imaging was undergoing nonlinear distortion and generated harmonics in tissue will be discussed. The far-reaching implications of the advent of the piezoelectric PVDF polymer material will be reviewed and the advances in ultrasound metrology prompted by the regulatory agencies such as US Food and Drug Administration (FDA) and International Electrotechnical Commission (IEC) will be presented. These advances include the development of absolute calibration techniques for hydrophones along with the methods of accounting for spatial averaging corrections up to 100 MHz and the development of “point-receiver” hydrophone probes utilizing acousto-optic sensors. Next, selected therapeutic applications of nonlinear ultrasonics (NLU), including lithotripters will be briefly discussed. Also, the use of shock waves as pain relief tool and in abating penicillin resistant bacteria that develop rock hard “biofilm” that can be shattered by the finite amplitude wave will also be mentioned. The growing applications of NLU in cosmetic industry where it is used for redistribution and reduction of fatty tissue within the body will be briefly reviewed, and, finally, selected examples of NLU applications in retail and entertainment industry will also be pointed out

    Fabrication and characterisation of microultrasound array transducers

    Get PDF
    No abstract available
    • …
    corecore