1,555 research outputs found

    Modeling and Simulation in Engineering

    Get PDF
    This book provides an open platform to establish and share knowledge developed by scholars, scientists, and engineers from all over the world, about various applications of the modeling and simulation in the design process of products, in various engineering fields. The book consists of 12 chapters arranged in two sections (3D Modeling and Virtual Prototyping), reflecting the multidimensionality of applications related to modeling and simulation. Some of the most recent modeling and simulation techniques, as well as some of the most accurate and sophisticated software in treating complex systems, are applied. All the original contributions in this book are jointed by the basic principle of a successful modeling and simulation process: as complex as necessary, and as simple as possible. The idea is to manipulate the simplifying assumptions in a way that reduces the complexity of the model (in order to make a real-time simulation), but without altering the precision of the results

    Intraoperative Endoscopic Augmented Reality in Third Ventriculostomy

    Get PDF
    In neurosurgery, as a result of the brain-shift, the preoperative patient models used as a intraoperative reference change. A meaningful use of the preoperative virtual models during the operation requires for a model update. The NEAR project, Neuroendoscopy towards Augmented Reality, describes a new camera calibration model for high distorted lenses and introduces the concept of active endoscopes endowed with with navigation, camera calibration, augmented reality and triangulation modules

    Evaluation of the results of orthodontic treatment by non-rigid image registration and deformation-based morphometry

    Get PDF
    The goal of this research was to find out, whether the non-rigid registration of dental casts can be used in the evaluation of orthodontic treatment and to develop a program, which would at least partially automatize the evaluation process of images. The aim was also to experiment the evaluation of three-dimensional models of the casts. This research was delimited to cover only the evaluation of malocclusions within the dental arch. The relationships between the dental arches were not considered. This thesis was done in the University of Vaasa at the Department of Electrical Engineering and Energy Technology as a part of the HammasSkanneri research project, whose aim is to automatize the digitization and archiving of dental casts. This research used two-dimensional images of dental casts which were taken of orthodontically treated patients before and after orthodontic treatment. Non-rigid registration was performed by using a registration tool of Fiji software. The evaluation of the accuracy of the registration was performed by measuring distances between manually inserted landmarks, and by comparing the linear and angular parameters of the registered images and the original target images. The displacements of the teeth were approximated with the help of deformation-based morphometry. The accuracy of registration is within reasonable error limits, if the image is taken straight from above of the cast and the registration is performed with the help of landmarks inserted by a human. Estimation of the changes showed that the movement of teeth can be coarsely measured by using deformation-based morphometry based on change estimates that resemble the Jacobian estimates. A set of programs, which partially automatize the evaluation of the accuracy and the changes, were developed. Three-dimensional imaging of the casts was unsuccessful, and thus the development of 3D evaluation system was left as a future research topic.fi=Opinnäytetyö kokotekstinä PDF-muodossa.|en=Thesis fulltext in PDF format.|sv=Lärdomsprov tillgängligt som fulltext i PDF-format

    Computer vision and optimization methods applied to the measurements of in-plane deformations

    Get PDF
    fi=vertaisarvioitu|en=peerReviewed

    3D surface reconstruction for lower limb prosthetic model using modified radon transform

    Get PDF
    Computer vision has received increased attention for the research and innovation on three-dimensional surface reconstruction with aim to obtain accurate results. Although many researchers have come up with various novel solutions and feasibility of the findings, most require the use of sophisticated devices which is computationally expensive. Thus, a proper countermeasure is needed to resolve the reconstruction constraints and create an algorithm that is able to do considerably fast reconstruction by giving attention to devices equipped with appropriate specification, performance and practical affordability. This thesis describes the idea to realize three-dimensional surface of the residual limb models by adopting the technique of tomographic imaging coupled with the strategy based on multiple-views from a digital camera and a turntable. The surface of an object is reconstructed from uncalibrated two-dimensional image sequences of thirty-six different projections with the aid of Radon transform algorithm and shape-from-silhouette. The results show that the main objective to reconstruct three-dimensional surface of lower limb model has been successfully achieved with reasonable accuracy as the starting point to reconstruct three-dimensional surface and extract digital reading of an amputated lower limb model where the maximum percent error obtained from the computation is approximately 3.3 % for the height whilst 7.4%, 7.9% and 8.1% for the diameters at three specific heights of the objects. It can be concluded that the reconstruction of three-dimensional surface for the developed method is particularly dependent to the effects the silhouette generated where high contrast two-dimensional images contribute to higher accuracy of the silhouette extraction. The advantage of the concept presented in this thesis is that it can be done with simple experimental setup and the reconstruction of three-dimensional model neither involves expensive equipment nor require any service by an expert to handle sophisticated mechanical scanning system

    AN AUTOMATED, DEEP LEARNING APPROACH TO SYSTEMATICALLY & SEQUENTIALLY DERIVE THREE-DIMENSIONAL KNEE KINEMATICS DIRECTLY FROM TWO-DIMENSIONAL FLUOROSCOPIC VIDEO

    Get PDF
    Total knee arthroplasty (TKA), also known as total knee replacement, is a surgical procedure to replace damaged parts of the knee joint with artificial components. It aims to relieve pain and improve knee function. TKA can improve knee kinematics and reduce pain, but it may also cause altered joint mechanics and complications. Proper patient selection, implant design, and surgical technique are important for successful outcomes. Kinematics analysis plays a vital role in TKA by evaluating knee joint movement and mechanics. It helps assess surgery success, guides implant and technique selection, informs implant design improvements, detects problems early, and improves patient outcomes. However, evaluating the kinematics of patients using conventional approaches presents significant challenges. The reliance on 3D CAD models limits applicability, as not all patients have access to such models. Moreover, the manual and time-consuming nature of the process makes it impractical for timely evaluations. Furthermore, the evaluation is confined to laboratory settings, limiting its feasibility in various locations. This study aims to address these limitations by introducing a new methodology for analyzing in vivo 3D kinematics using an automated deep learning approach. The proposed methodology involves several steps, starting with image segmentation of the femur and tibia using a robust deep learning approach. Subsequently, 3D reconstruction of the implants is performed, followed by automated registration. Finally, efficient knee kinematics modeling is conducted. The final kinematics results showed potential for reducing workload and increasing efficiency. The algorithms demonstrated high speed and accuracy, which could enable real-time TKA kinematics analysis in the operating room or clinical settings. Unlike previous studies that relied on sponsorships and limited patient samples, this algorithm allows the analysis of any patient, anywhere, and at any time, accommodating larger subject populations and complete fluoroscopic sequences. Although further improvements can be made, the study showcases the potential of machine learning to expand access to TKA analysis tools and advance biomedical engineering applications
    corecore