189 research outputs found

    Cardiovascular instrumentation for spaceflight

    Get PDF
    The observation mechanisms dealing with pressure, flow, morphology, temperature, etc. are discussed. The approach taken in the performance of this study was to (1) review ground and space-flight data on cardiovascular function, including earlier related ground-based and space-flight animal studies, Mercury, Gemini, Apollo, Skylab, and recent bed-rest studies, (2) review cardiovascular measurement parameters required to assess individual performance and physiological alternations during space flight, (3) perform an instrumentation survey including a literature search as well as personal contact with the applicable investigators, (4) assess instrumentation applicability with respect to the established criteria, and (5) recommend future research and development activity. It is concluded that, for the most part, the required instrumentation technology is available but that mission-peculiar criteria will require modifications to adapt the applicable instrumentation to a space-flight configuration

    Liquid flow measurement using silicone polymer wedge clamp-on ultrasonic transducers

    Get PDF
    Accurate liquid flow measurement is vital to many industries, and the benefits and limitations of ultrasonic transit-time clamp-on measurements are well understood. The ultrasonic transducers used in high quality clamp-on systems tend to be high cost items, containing an ultrasonic wedge of machined polyether ether ketone plastic (PEEK). PEEK is used because of its consistency and favourable ultrasonic properties of relatively low attenuation and consistent ultrasonic wave velocity over a wide range of frequencies. The viability of a new, high performance and low cost design of clamp-on ultrasonic transducers is described, made from a silicone based polymer moulded inside a shell and directly bonded to the active piezoelectric element. In addition to the reduced material and production cost, the new transducers have good thermal stability, consistency, conform well to the surface of the pipe. Tests were performed on a flow rig and on calibration blocks for thermal stability tests, showing that the sensors are of comparable performance to quality devices constructed using PEEK wedges

    Development of ultrasonic methods for hemodynamic measurements

    Get PDF
    A transcutanous method to measure instantaneous mean blood flow in peripheral arteries of the human body was defined. Transcutanous and implanted cuff ultrasound velocity measurements were evaluated, and the accuracies of velocity, flow, and diameter measurements were assessed for steady flow. Performance criteria were established for the pulsed Doppler velocity meter (PUDVM), and performance tests were conducted. Several improvements are suggested

    Ultrasonic Beam Propagation in Turbulent Flow

    Get PDF
    This study was conducted to examine the effect of flow turbulence on sound waves propagating across a velocity field. The resulting information can be used to determine the potential for increasing the accuracy of an ultrasonic flowmeter, and understand the data scatter typically seen when using an ultrasonic flowmeter. A modification of the Ray Trace Method was employed which enabled the use of multiple rays in a very fine grid through a flow field. This technique allowed for the computation of the statistical variation of the propagation times for sound pulses traversing a flow field. The statistical variation was studied using two flow fields: 1) a uniform flow field with a superimposed vortex street and 2) an experimentally measured channel flow. The uniform flow field with a superimposed vortex street allowed for the examination of the effects of a large-scale flow structure on sound wave propagation, and for the verification of the analysis technique. Next by using the measured turbulent channel flow, as an example, the statistical variation of sound pulse propagation time was computed for flow likely to be encountered in actual flow measurement situations. Analysis was also conducted to determine the maximum allowable repetition rate of measurements with regard to the optimal time of flight measurements. Both the propagation time of a sound pulse moving across a uniform flow field with superimposed vortex street, and the resultant computed flow were observed to vary at the same frequency of the vortex street. Further, the magnitude of the variations was proportional with the strength of the individual vortices in the vortex street. A sound pulse propagating back and forth across a measured turbulent channel flow, afforded individual time difference variation from the mean propagation time of up to 5%. It was shown that a minimum variation occurred when the sound pulses were transmitted at a 75 degree angle to the flow axis. It was also determined that the average speed of sound in a flow field affected the final flow measurements by decreasing the measured delta time difference between the upstream and downstream propagating sound waves, and therefore the measured flow. The width of the sound path also contributed to decreasing the variation of the individual measurements by integrating over a larger sound path. These findings suggest that turbulence in a flow field affects ultrasonic flowmeter measurements by creating differences in the propagation times of individual sound pulses. Thus, turbulence and large-scale flow structures can result in variations in volumetric flow rate determination made by an ultrasonic flowmeter system

    Flow rate measurement in a high temperature, radioactive, and corrosive environment

    Full text link
    Accurate measurement of coolant flow rate is essential for determining the maximum power required by the nuclear plant operation and critical for monitoring its operation safety. However, no practical off-the-shelf flowmeter is available to satisfy all the pressing multidimensional operation requirements (i. e., high temperature, high irradiation, and high corrosion). This work thus deals with the development of a new flowmeter for nuclear power plant/reactor process-monitoring and real time analysis; this proposed flowmeter shall be able to continuously conduct robust measurements under extremely harsh environment with high irradiation, high pressure, high temperature and corrosive media. We investigate a transit-time based flow rate measurement which is used in such environment. The transit time of a thermal signal travels along with a liquid flow can be obtained using a cross correlation method. This transit-time-based flowmeter using thermocouples with grounded stainless steel shielding is by far the most robust and reliable solution to measure the flow rate in a harsh environment typically seen in a nuclear reactor. In practice, cross correlation calculation tends to produce flat peak plateau or multiple peaks, leading to a significant error in peak detection. To overcome this problem, in this work, an Auto-Adaptive Impulse Response Function estimation (AAIRF) technique is introduced and a significantly narrower peak is shown theoretically and also verified experimentally. In addition, we show that more accurate results can be obtained if moving average filter based cross correlation function (MAFCCF) is combined with AAIRF. Also in this work, we investigate a few important practical problems related to negative delays and sampling frequencies of the data acquisition. The second part of this work deals with the calibration of the developed flowmeter which was mentioned above. To commission the flowmeter, calibration process is applied by comparing the reading measurements with a standard flowmeter measurement. In this work, this process is performed in an in house developed water-based test apparatus with a developed transit-time based flowmeter based on the measurement and processing of correlated thermal signals. In this system, we have observed that the accuracy of the measured flow is restricted to the time response of the thermocouples. In addition, since the flow rate is inversely proportional to estimated time delay, high flow rates measurement like 5 gpm (gallon per minute) requires large transit-time span that can not be achieved from a limited physical system dimensions. These problems are investigated through this work. In the final part of this work, as the ultrasonic flow measurement technologies including transit-time and Doppler effect technologies are usually used in harsh environments, we study these methods with intensive simulations

    Multiphase flow measurement in the slug regime using ultrasonic measurement techniques and slug closure model

    Get PDF
    Multiphase flow in the oil and gas industry covers a wide range of flows. Thus, over the last decade, the investigation, development and use of multiphase flow metering system have been a major focus for the industry worldwide. However, these meters do not perform well in slug flow conditions. The present work involves experimental investigations of multiphase flow measurement under slug flow conditions. A two-phase gas/liquid facility was designed and constructed at Cranfield University. It consisted of a 0.05 m diameter 25 m long horizontal pipeline with the necessary instrumentation. An ultrasonic multiphase metering concept has been proposed and investigated. The concept was based on the combination of non-invasive and non-intrusive ultrasonic sensors and a slug closure model. The slug closure model was based on the "slug unit" model to infer the gas and liquid phase volumetric flowrates. The slug characteristics obtained by non-invasive and non-intrusive ultrasonic techniques were inputs to slug closure model which calculates the factors KI (Liquid), K2 (Liquid), K3 (Gas) and K4 (Gas). These factors are function of the slip ratio in the slug body, flow profile (CO), drift velocity (Vd), liquid holdup and gas void fraction in slug body, slug length, film length, and the total length of the slug unit. Based on ultrasonic sensor measurements, the slug translational velocity was estimated and the slug closure model then calculates the gas and liquid phase volumetric flowrates. Air water slug flow data were gathered and processed for a range of superficial velocities VSL=0.3 to 1.03 ms'1 and VsG=0.6 to 3.01 ms'1. The overall goal of a 5% relative error metering for both phases was not achieved for the conditions tested. The liquid phase percentage errors were from -63.6% to 45.4% while the gas phase percentage errors were from 42% to -14.6%. Key words: slug flow, slug characteristics, slug closure model, non-invasive ultrasonic, non-intrusive ultrasonic, clamp-on transit time ultrasonic flowmeter

    Experimental investigations of two-phase flow measurement using ultrasonic sensors

    Get PDF
    This thesis presents the investigations conducted in the use of ultrasonic technology to measure two-phase flow in both horizontal and vertical pipe flows which is important for the petroleum industry. However, there are still key challenges to measure parameters of the multiphase flow accurately. Four methods of ultrasonic technologies were explored. The Hilbert-Huang transform (HHT) was first applied to the ultrasound signals of air-water flow on horizontal flow for measurement of the parameters of the two- phase slug flow. The use of the HHT technique is sensitive enough to detect the hydrodynamics of the slug flow. The results of the experiments are compared with correlations in the literature and are in good agreement. Next, experimental data of air-water two-phase flow under slug, elongated bubble, stratified-wavy and stratified flow regimes were used to develop an objective flow regime classification of two-phase flow using the ultrasonic Doppler sensor and artificial neural network (ANN). The classifications using the power spectral density (PSD) and discrete wavelet transform (DWT) features have accuracies of 87% and 95.6% respectively. This is considerably more promising as it uses non-invasive and non-radioactive sensors. Moreover, ultrasonic pulse wave transducers with centre frequencies of 1MHz and 7.5MHz were used to measure two-phase flow both in horizontal and vertical flow pipes. The liquid level measurement was compared with the conductivity probes technique and agreed qualitatively. However, in the vertical with a gas volume fraction (GVF) higher than 20%, the ultrasound signals were attenuated. Furthermore, gas-liquid and oil-water two-phase flow rates in a vertical upward flow were measured using a combination of an ultrasound Doppler sensor and gamma densitometer. The results showed that the flow gas and liquid flow rates measured are within ±10% for low void fraction tests, water-cut measurements are within ±10%, densities within ±5%, and void fractions within ±10%. These findings are good results for a relatively fast flowing multiphase flow

    Overview of biofluids and flow sensing techniques applied in clinical practice

    Get PDF
    This review summarizes the current knowledge on biofluids and the main flow sensing techniques applied in healthcare today. Since the very beginning of the history of medicine, one of the most important assets for evaluating various human diseases has been the analysis of the conditions of the biofluids within the human body. Hence, extensive research on sensors intended to evaluate the flow of many of these fluids in different tissues and organs has been published and, indeed, continues to be published very frequently. The purpose of this review is to provide researchers interested in venturing into biofluid flow sensing with a concise description of the physiological characteristics of the most important body fluids that are likely to be altered by diverse medical conditions. Similarly, a reported compilation of well-established sensors and techniques currently applied in healthcare regarding flow sensing is aimed at serving as a starting point for understanding the theoretical principles involved in the existing methodologies, allowing researchers to determine the most suitable approach to adopt according to their own objectives in this broad field.This research was supported by the Consejo Nacional de Ciencia y Tecnología (CONACYT) of México through Ph.D. grant 472102 and by the Ministerio de Economía y Competitividad through grant FIS2017-89850R.Peer ReviewedPostprint (author's final draft

    The development of biomedical instrumentation using backscattered laser light

    Get PDF
    This thesis is concerned with the measurement of blood flow and oxygen saturation in the microcirculation using the techniques of laser Doppler flowmetry and pulse oximetry. An investigation of the responses of Doppler flowmeters using different signal processing bandwidths and laser sources revealed two major findings. Firstly, that careful choice of processing bandwidth is required in order to sample the whole range of possible Doppler frequencies present in the backscattered light. Secondly, that the choice of laser source is important in governing the output stability of a flowmeter. Another investigation focused on the evaluation of a dual channel laser Doppler flowmeter using both in vitro and in vivo models. It was demonstrated that the instrument permitted a useful method of obtaining flow information by comparing simultaneous responses at experimental and control sites. The choice of laser wavelength was investigated in a study to determine whether blood flow measurements are obtained from different depths within the skin tissue. The results indicate that some depth discrimination is obtainable using instruments operating at different wavelengths, however it is difficult to demonstrate the effect in vivo. In a separate study it was shown that pressure applied to the skin surface greatly affects the underlying blood flow. It is recommended that care has to be taken when positioning Doppler probes on the skin. A reflection pulse oximeter was developed using laser light backscattered from the skin. The instrument was evaluated in vitro and in vivo by comparing desaturation responses with a commercial transmission pulse oximeter. The reflection oximeter was demonstrated to reliably follow trends in oxygen saturation but several problems prevented instrument calibration. Finally, a device combining laser Doppler flowmetry with reflection pulse oximetry was developed and used in vivo to follow trends in blood flow and oxygen saturation from the same tissue sample
    • …
    corecore