24,038 research outputs found

    Quantifying subjective quality evaluations for mobile video watching in a semi-living lab context

    Get PDF
    This paper discusses results from an exploratory study in which Quality of Experience aspects related to mobile video watching were investigated in a semi-living lab setting. More specifically, we zoom in on usage patterns in a natural research context and on the subjective evaluation of high and low-resolution movie trailers that are transferred to a mobile device using two transmission protocols for video (i.e., real-time transport protocol and progressive download using HTTP). User feedback was collected by means of short questionnaires on the mobile device, combined with traditional pen and paper diaries. The subjective evaluations regarding the general technical quality, perceived distortion, fluentness of the video, and loading speed are studied and the influence of the transmission protocol and video resolution on these evaluations is analyzed. Multinomial logistic regression results in a model to estimate the subjective evaluations regarding the perceived distortion and loading speed based on objectively-measured parameters of the video session

    Intervertebral disc characterization by shear wave elastography: an in-vitro preliminary study

    Get PDF
    Patient-specific numerical simulation of the spine is a useful tool both in clinic and research. While geometrical personalization of the spine is no more an issue, thanks to recent technological advances, non-invasive personalization of soft tissue’s mechanical properties remains a challenge. Ultrasound elastography is a relatively recent measurement technique allowing the evaluation of soft tissue’s elastic modulus through the measurement of shear wave speed (SWS). The aim of this study was to determine the feasibility of elastographic measurements in intervertebral disc (IVD). An in-vitro approach was chosen to test the hypothesis that SWS can be used to evaluate IVD mechanical properties and to assess measurement repeatability. Eleven oxtail IVDs were tested in compression to determine their stiffness and apparent elastic modulus at rest and at 400 N. Elastographic measurements were performed in these two conditions and compared to these mechanical parameters. The protocol was repeated six times to determine elastographic measurement repeatability. Average SWS over all samples was 5.3 ± 1.0 m/s, with a repeatability of 7 % at rest and 4.6 % at 400 N; stiffness and apparent elastic modulus were 266.3 ± 70.5 N/mm and 5.4 ± 1.1 MPa at rest, respectively, while at 400 N they were 781.0 ± 153.8 N/mm and 13.2 ± 2.4 MPa. Correlations were found between elastographic measurements and IVD mechanical properties; these preliminary results are promising for further in-vivo application.The authors are grateful to the ParisTech BiomecAM chair program on subject-specific musculoskeletal modelling for funding (with the support of Proteor, ParisTech and Yves Cotrel Foundations)

    RLFC: Random Access Light Field Compression using Key Views and Bounded Integer Encoding

    Full text link
    We present a new hierarchical compression scheme for encoding light field images (LFI) that is suitable for interactive rendering. Our method (RLFC) exploits redundancies in the light field images by constructing a tree structure. The top level (root) of the tree captures the common high-level details across the LFI, and other levels (children) of the tree capture specific low-level details of the LFI. Our decompressing algorithm corresponds to tree traversal operations and gathers the values stored at different levels of the tree. Furthermore, we use bounded integer sequence encoding which provides random access and fast hardware decoding for compressing the blocks of children of the tree. We have evaluated our method for 4D two-plane parameterized light fields. The compression rates vary from 0.08 - 2.5 bits per pixel (bpp), resulting in compression ratios of around 200:1 to 20:1 for a PSNR quality of 40 to 50 dB. The decompression times for decoding the blocks of LFI are 1 - 3 microseconds per channel on an NVIDIA GTX-960 and we can render new views with a resolution of 512X512 at 200 fps. Our overall scheme is simple to implement and involves only bit manipulations and integer arithmetic operations.Comment: Accepted for publication at Symposium on Interactive 3D Graphics and Games (I3D '19

    Implementation of a Matrix Crack Spacing Parameter in a Continuum Damage Mechanics Finite Element Model

    Get PDF
    Continuum Damage Mechanics (CDM) based progressive damage and failure analysis (PDFA) methods have demonstrated success in a variety of finite element analysis (FEA) implementations. However, the technical maturity of CDM codes has not yet been proven for the full design space of composite materials in aerospace applications. CDM-based approaches represent the presence of damage by changing the local material stiffness definitions and without updating the original mesh or element integration schemes. Without discretely representing cracks and their paths through the mesh, damage in models with CDM-based materials is often distributed in a region of partially damaged elements ahead of stress concentrations. Having a series of discrete matrix cracks represented by a softened region may affect predictions of damage propagation and, thus, structural failure. This issue can be mitigated by restricting matrix damage development to discrete, fiber-aligned rows of elements; hence CDM-based matrix cracks can be implemented to be more representative of discrete matrix cracks. This paper evaluates the effect of restricting CDM matrix crack development to discrete, fiber-aligned rows where the spacing of these rows is controlled by a user-defined crack spacing parameter. Initially, the effect of incrementally increasing matrix crack spacing in a unidirectional center notch coupon is evaluated. Then, the lessons learned from the center notch specimen are applied to open-hole compression finite element models. Results are compared to test data, and the limitations, successes, and potential of the matrix crack spacing approach are discussed

    Low-cycle full-field residual strains in cortical bone and their influence on tissue fracture evaluated via in situ stepwise and continuous X-ray computed tomography

    Get PDF
    As a composite material, the mechanical properties of bone are highly dependent on its hierarchical organisation, thus, macroscopic mechanical properties are dictated by local phenomena, such as microdamage resulting from repetitive cyclic loading of daily activities. Such microdamage is associated with plastic deformation and appears as a gradual accumulation of residual strains. The aim of this study is to investigate local residual strains in cortical bone tissue following compressive cyclic loading, using in situ X-ray computed tomography (XCT) and digital volume correlation (DVC) to provide a deeper insight on the three-dimensional (3D) relationship between residual strain accumulation, cortical bone microstructure and failure patterns. Through a progressive in situ XCT loading–unloading scheme, localisation of local residual strains was observed in highly compressed regions. In addition, a multi-scale in situ XCT cyclic test highlighted the differences on residual strain distribution at the microscale and tissue level, where high strains were observed in regions with the thinnest vascular canals and predicted the failure location following overloading. Finally, through a continuous in situ XCT compression test of cycled specimens, the full-field strain evolution and failure pattern indicated the reduced ability of bone to plastically deform after damage accumulation due to high number of cyclic loads. Altogether, the novel experimental methods employed in this study, combining high-resolution in situ XCT mechanics and DVC, showed a great potential to investigate 3D full-field residual strain development under repetitive loading and its complex interaction with bone microstructure, microdamage and fracture
    corecore