1,879 research outputs found

    Using the Microsoft Kinect to assess human bimanual coordination

    Get PDF
    Optical marker-based systems are the gold-standard for capturing three-dimensional (3D) human kinematics. However, these systems have various drawbacks including time consuming marker placement, soft tissue movement artifact, and are prohibitively expensive and non-portable. The Microsoft Kinect is an inexpensive, portable, depth camera that can be used to capture 3D human movement kinematics. Numerous investigations have assessed the Kinect\u27s ability to capture postural control and gait, but to date, no study has evaluated it\u27s capabilities for measuring spatiotemporal coordination. In order to investigate human coordination and coordination stability with the Kinect, a well-studied bimanual coordination paradigm (Kelso, 1984, Kelso; Scholz, & Schöner, 1986) was adapted. ^ Nineteen participants performed ten trials of coordinated hand movements in either in-phase or anti-phase patterns of coordination to the beat of a metronome which was incrementally sped up and slowed down. Continuous relative phase (CRP) and the standard deviation of CRP were used to assess coordination and coordination stability, respectively.^ Data from the Kinect were compared to a Vicon motion capture system using a mixed-model, repeated measures analysis of variance and intraclass correlation coefficients (2,1) (ICC(2,1)).^ Kinect significantly underestimated CRP for the the anti-phase coordination pattern (p \u3c.0001) and overestimated the in-phase pattern (p\u3c.0001). However, a high ICC value (r=.097) was found between the systems. For the standard deviation of CRP, the Kinect exhibited significantly higher variability than the Vicon (p \u3c .0001) but was able to distinguish significant differences between patterns of coordination with anti-phase variability being higher than in-phase (p \u3c .0001). Additionally, the Kinect was unable to accurately capture the structure of coordination stability for the anti-phase pattern. Finally, agreement was found between systems using the ICC (r=.37).^ In conclusion, the Kinect was unable to accurately capture mean CRP. However, the high ICC between the two systems is promising and the Kinect was able to distinguish between the coordination stability of in-phase and anti-phase coordination. However, the structure of variability as movement speed increased was dissimilar to the Vicon, particularly for the anti-phase pattern. Some aspects of coordination are nicely captured by the Kinect while others are not. Detecting differences between bimanual coordination patterns and the stability of those patterns can be achieved using the Kinect. However, researchers interested in the structure of coordination stability should exercise caution since poor agreement was found between systems

    Gesture based Human Computer Interaction for Athletic Training

    Get PDF
    The invention of depth sensors for mobile devices, has led to availability of relatively inexpensive high-resolution depth and visual (RGB) sensing for a wide range of applications. The complementary nature of the depth and visual information opens up new opportunities to solve fundamental problems in object and activity recognition, people tracking, 3D mapping and localization, etc. One of the most interesting challenges that can be tackled by using these sensors is tracking the body movements of athletes and providing natural interaction as a result. In this study depth sensors and gesture recognition tools will be used to analyze the position and angle of an athlete’s body parts thought out an exercise. The goal is to assess the training performance of an athlete and decrease injury risk by giving warnings when the trainer is performing a high risk activity

    Evaluation of Pose Tracking Accuracy in the First and Second Generations of Microsoft Kinect

    Full text link
    Microsoft Kinect camera and its skeletal tracking capabilities have been embraced by many researchers and commercial developers in various applications of real-time human movement analysis. In this paper, we evaluate the accuracy of the human kinematic motion data in the first and second generation of the Kinect system, and compare the results with an optical motion capture system. We collected motion data in 12 exercises for 10 different subjects and from three different viewpoints. We report on the accuracy of the joint localization and bone length estimation of Kinect skeletons in comparison to the motion capture. We also analyze the distribution of the joint localization offsets by fitting a mixture of Gaussian and uniform distribution models to determine the outliers in the Kinect motion data. Our analysis shows that overall Kinect 2 has more robust and more accurate tracking of human pose as compared to Kinect 1.Comment: 10 pages, IEEE International Conference on Healthcare Informatics 2015 (ICHI 2015

    The Design and Evaluation of a Kinect-Based Postural Symmetry Assessment and Training System

    Get PDF
    abstract: The increased risk of falling and the worse ability to perform other daily physical activities in the elderly cause concern about monitoring and correcting basic everyday movement. In this thesis, a Kinect-based system was designed to assess one of the most important factors in balance control of human body when doing Sit-to-Stand (STS) movement: the postural symmetry in mediolateral direction. A symmetry score, calculated by the data obtained from a Kinect RGB-D camera, was proposed to reflect the mediolateral postural symmetry degree and was used to drive a real-time audio feedback designed in MAX/MSP to help users adjust themselves to perform their movement in a more symmetrical way during STS. The symmetry score was verified by calculating the Spearman correlation coefficient with the data obtained from Inertial Measurement Unit (IMU) sensor and got an average value at 0.732. Five healthy adults, four males and one female, with normal balance abilities and with no musculoskeletal disorders, were selected to participate in the experiment and the results showed that the low-cost Kinect-based system has the potential to train users to perform a more symmetrical movement in mediolateral direction during STS movement.Dissertation/ThesisMasters Thesis Electrical Engineering 201

    Real-time human ambulation, activity, and physiological monitoring:taxonomy of issues, techniques, applications, challenges and limitations

    Get PDF
    Automated methods of real-time, unobtrusive, human ambulation, activity, and wellness monitoring and data analysis using various algorithmic techniques have been subjects of intense research. The general aim is to devise effective means of addressing the demands of assisted living, rehabilitation, and clinical observation and assessment through sensor-based monitoring. The research studies have resulted in a large amount of literature. This paper presents a holistic articulation of the research studies and offers comprehensive insights along four main axes: distribution of existing studies; monitoring device framework and sensor types; data collection, processing and analysis; and applications, limitations and challenges. The aim is to present a systematic and most complete study of literature in the area in order to identify research gaps and prioritize future research directions

    Assessing the kinect’s capabilities to perform a time-based clinical test for fall risk assessment in older people

    Full text link
    © 2014 IFIP International Federation for Information Processing. The Choice Stepping Reaction Time (CSRT) task is time-based clinical test that has shown to reliably predict falls in older adults. Its current mode of delivery involves the use of a custom-made dance mat device. This mat is a measurement tool that can reliably obtain step data to discriminate between fallers and non-fallers. One of the pitfalls of this test is that the technology in use still imposes an obstacle on the degree of freedom to be able to perform adaptive exercises suitable for the elderly. In this paper, we describe a Kinect-based system that measures stepping performance through the use of a hybrid version of the CSRT task. This study focuses on assessing this system’s capabilities to reliably measure a time-based clinical test of fall risk. Results showed a favorable correspondence and agreement between the two systems, suggesting that this platform could be potentially useful in the clinical practice

    Enhancing the measurement of clinical outcomes using Microsoft Kinect

    Get PDF
    There is a growing body of applications leveraging Microsoft Kinect and the associated Windows Software Development Kit in health and wellness. In particular, this platform has been valuable in developing interactive solutions for rehabilitation including creating more engaging exercise regimens and ensuring that exercises are performed correctly for optimal outcomes. Clinical trials rely upon robust and validated methodologies to measure health status and to detect treatment-related changes over time to enable the efficacy and safety of new drug treatments to be assessed and measured. In many therapeutic areas, traditional outcome measures rely on subjective investigator and patient ratings. Subjective ratings are not always sensitive to detecting small improvements, are subject to inter- and intra-rater variability and limited in their ability to record detailed or subtle aspects of movement and mobility. For these reasons, objective measurements may provide greater sensitivity to detect treatment-related changes where they exist. In this review paper, we explore the use of the Kinect platform to develop low-cost approaches to objectively measure aspects of movement. We consider published applications that measure aspects of gait and balance, upper extremity movement, chest wall motion and facial analysis. In each case, we explore the utility of the approach for clinical trials, and the precision and accuracy of estimates derived from the Kinect output. We conclude that the use of games platforms such as Microsoft Kinect to measure clinical outcomes offer a versatile, easy to use and low-cost approach that may add significant value and utility to clinical drug development, in particular in replacing conventional subjective measures and providing richer information about movement than previously possible in large scale clinical trials, especially in the measurement of gross spatial movements. Regulatory acceptance of clinical outcomes collected in this way will be subject to comprehensive assessment of validity and clinical relevance, and this will require good quality peer-reviewed publications of scientific evidence

    Radar and RGB-depth sensors for fall detection: a review

    Get PDF
    This paper reviews recent works in the literature on the use of systems based on radar and RGB-Depth (RGB-D) sensors for fall detection, and discusses outstanding research challenges and trends related to this research field. Systems to detect reliably fall events and promptly alert carers and first responders have gained significant interest in the past few years in order to address the societal issue of an increasing number of elderly people living alone, with the associated risk of them falling and the consequences in terms of health treatments, reduced well-being, and costs. The interest in radar and RGB-D sensors is related to their capability to enable contactless and non-intrusive monitoring, which is an advantage for practical deployment and users’ acceptance and compliance, compared with other sensor technologies, such as video-cameras, or wearables. Furthermore, the possibility of combining and fusing information from The heterogeneous types of sensors is expected to improve the overall performance of practical fall detection systems. Researchers from different fields can benefit from multidisciplinary knowledge and awareness of the latest developments in radar and RGB-D sensors that this paper is discussing
    • …
    corecore