    The 2023 wearable photoplethysmography roadmap

    Get PDF
    Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology

    A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability

    Get PDF
    Background: Photoplethysmography (PPG) is a low-cost and easy-to-implement method to measure vital signs, including heart rate (HR) and pulse rate variability (PRV) which widely used as a substitute of heart rate variability (HRV). The method is used in various wearable devices. For example, Samsung smartwatches are PPG-based open-source wristbands used in remote well-being monitoring and fitness applications. However, PPG is highly susceptible to motion artifacts and environmental noise. A validation study is required to investigate the accuracy of PPG-based wearable devices in free-living conditions.Objective: We evaluate the accuracy of PPG signals-collected by the Samsung Gear Sport smartwatch in free-living conditions-in terms of HR and time-domain and frequency-domain HRV parameters against a medical-grade chest electrocardiogram (ECG) monitor.Methods: We conducted 24-hours monitoring using a Samsung Gear Sport smartwatch and a Shimmer3 ECG device. The monitoring included 28 participants (14 male and 14 female), where they engaged in their daily routines. We evaluated HR and HRV parameters during the sleep and awake time. The parameters extracted from the smartwatch were compared against the ECG reference. For the comparison, we employed the Pearson correlation coefficient, Bland-Altman plot, and linear regression methods.Results: We found a significantly high positive correlation between the smartwatch's and Shimmer ECG's HR, time-domain HRV, LF, and HF and a significant moderate positive correlation between the smartwatch's and shimmer ECG's LF/HF during sleep time. The mean biases of HR, time-domain HRV, and LF/HF were low, while the biases of LF and HF were moderate during sleep. The regression analysis showed low error variances of HR, AVNN, and pNN50, moderate error variances of SDNN, RMSSD, LF, and HF, and high error variances of LF/HF during sleep. During the awake time, there was a significantly high positive correlation of AVNN and a moderate positive correlation of HR, while the other parameters indicated significantly low positive correlations. RMSSD and SDNN showed low mean biases, and the other parameters had moderate mean biases. In addition, AVNN had moderate error variance while the other parameters indicated high error variances.Conclusion: The Samsung smartwatch provides acceptable HR, time-domain HRV, LF, and HF parameters during sleep time. In contrast, during the awake time, AVNN and HR show satisfactory accuracy, and the other HRV parameters have high errors.</p

    Tunteiden Havaitseminen Arkielämässä Koneoppimisen ja Puettavien Laitteiden Avulla

    Get PDF
    Tavoitteet. Tämän tutkimuksen tavoitteena on arvioida tunteiden havaitsemisen mahdollisuutta arkielämässä puettavien laitteiden ja koneoppimismallien avulla. Tunnetiloilla on tärkeä rooli päätöksenteossa, havaitsemisessa ja käyttäytymisessä, mikä tekee objektiivisesta tunnetilojen havaitsemisesta arvokkaan tavoitteen, sekä mahdollisten sovellusten että tunnetiloja koskevan ymmärryksen syventämisen kannalta. Tunnetiloihin usein liittyy mitattavissa olevia fysiologisia ja käyttäymisen muutoksia, mikä mahdollistaa koneoppimismallien kouluttamisen muutoksia aiheuttaneen tunnetilan havaitsemiseksi. Suurin osa tunteiden havaitsemiseen liittyvästä tutkimuksesta on toteutettu laboratorio-olosuhteissa käyttämällä tunteita herättäviä ärsykkeitä tai tehtäviä, mikä herättää kysymyksen siitä että yleistyvätkö näissä olosuhteissa saadut tulokset arkielämään. Vaikka puettavien laitteiden ja kännykkäkyselyiden kehittyminen on helpottanut aiheen tutkimista arkielämässä, tutkimusta tässä ympäristössä on vielä niukasti. Tässä tutkimuksessa itseraportoituja tunnetiloja ennustetaan koneoppimismallien avulla arkielämässä havaittavissa olevien tunnetilojen selvittämiseksi. Lisäksi tutkimuksessa käytetään mallintulkintamenetelmiä mallien hyödyntämien yhteyksien tunnistamiseksi. Metodit. Aineisto tätä tutkielmaa varten on peräisin tutkimuksesta joka suoritettiin osana Helsingin Yliopiston ja VTT:n Sisu at Work projektia, missä 82:ta tietotyöläistä neljästä suomalaisesta organisaatiosta tutkittiin kolmen viikon ajan. Osallistujilla oli jakson aikana käytettävissään mittalaitteet jotka mittasivat fotoplethysmografiaa (PPG), ihon sähkönjohtavuutta (EDA) ja kiihtyvyysanturi (ACC) signaaleita, lisäksi heille esitettiin kysymyksiä koetuista tunnetiloista kolmesti päivässä puhelinsovelluksen avulla. Signaalinkäsittelymenetelmiä sovellettiin signaaleissa esiintyvien liikeartefaktien ja muiden ongelmien korjaamiseksi. Sykettä (HR) ja sykevälinvaihtelua (HRV) kuvaavia piirteitä irroitettiin PPG signaalista, fysiologista aktivaatiota kuvaavia piirteitä EDA signaalista, sekä liikettä kuvaavia piirteitä ACC signaalista. Seuraavaksi koneoppimismalleja koulutettiin ennustamaan raportoituja tunnetiloja irroitetujen piirteiden avulla. Mallien suoriutumista vertailtiin suhteessa odotusarvoihin havaittavissa olevien tunnetilojen määrittämiseksi. Lisäksi permutaatiotärkeyttä sekä Shapley additive explanations (SHAP) arvoja hyödynnettiin malleille tärkeiden yhteyksien selvittämiseksi. Tulokset ja johtopäätökset. Mallit tunnetiloille virkeä, keskittynyt ja innostunut paransivat suoriutumistaan yli odotusarvon, joista mallit tunnetilalle virkeä paransivat suoriutumista tilastollisesti merkitsevästi. Permutaatiotärkeys korosti liike- ja HRV-piirteiden merkitystä, kun SHAP arvojen tarkastelu nosti esiin matalan liikkeen, matalan EDA:n, sekä korkean HRV:n merkityksen mallien ennusteille. Nämä tulokset ovat lupaavia korkean aktivaation positiivisten tunnetilojen havaitsemiselle arkielämässä, sekä nostavat esiin mahdollisia yhteyksiä jatkotutkimusta varten.Objectives. This study aims to evaluate feasibility of affect detection in daily life using wearable devices and machine learning models. Affective states play an important role in decision making, perception and behaviour, making objective detection of affective states a desirable goal both for potential applications and as a way to gain insight into affective phenomena. Affective states have been found to have measurable physiological and behavioral changes, which allows training of machine learning models for detecting the underlying affects. Majority of affect detection studies have been conducted in laboratory conditions using affect elicitation stimuli or tasks, raising the question whether results from these studies will generalize to daily life. Although development of wearable devices and mobile surveys have facilitated evaluation in the context of daily life, research here remains sparse. In this study, self-reported affective states are predicted using machine learning models to identify which affective states can be detected in daily life. Additionally, model interpretation methods will be used to identify which relationships the models found important for their predictions. Methods. Data for this thesis came from a study conducted as a part of Sisu at Work project between University of Helsinki and VTT, where 82 knowledge workers from four Finnish organizations were studied for a period of three weeks. During this period, the participants were queried by mobile surveys about their affective states thrice a day, while they also used wearable devices to record photoplethysmography (PPG), electrodermal activity (EDA) and accelerometry (ACC) signals. A signal processing pipeline was implemented to deal with movement artefacts and other issues with the data. Features describing heart rate (HR) and heart rate variation (HRV) were extraced from PPG, physiological activation from EDA and movement from ACC signals. Models were then fitted to predict the reported affective states using the extracted features. Model performance was compared against a baseline to identify which affects could be reliably detected, while permutation importance and Shapley additive explanations (SHAP) values were used to identify important relationships established by the models. Results and conclusions. Models for affective state vigor showed improvements over baseline with statistical significance, while improvements were also noted for affects focused and enthusiastic. Permutation importance highlighted the significance of movement and HRV features, while examination of SHAP values indicated that low movement, low EDA and high HRV impacted model predictions the most. These results indicate potential for detecting high activation affective states in daily life and propose potential relationships for future research

    The Apple Watch for monitoring mental health–related physiological symptoms : literature review

    Get PDF
    Background: An anticipated surge in mental health service demand related to COVID-19 has motivated the use of novel methods of care to meet demand, given workforce limitations. Digital health technologies in the form of self-tracking technology have been identified as a potential avenue, provided sufficient evidence exists to support their effectiveness in mental health contexts. Objective: This literature review aims to identify current and potential physiological or physiologically related monitoring capabilities of the Apple Watch relevant to mental health monitoring and examine the accuracy and validation status of these measures and their implications for mental health treatment. Methods: A literature review was conducted from June 2021 to July 2021 of both published and gray literature pertaining to the Apple Watch, mental health, and physiology. The literature review identified studies validating the sensor capabilities of the Apple Watch. Results: A total of 5583 paper titles were identified, with 115 (2.06%) reviewed in full. Of these 115 papers, 19 (16.5%) were related to Apple Watch validation or comparison studies. Most studies showed that the Apple Watch could measure heart rate acceptably with increased errors in case of movement. Accurate energy expenditure measurements are difficult for most wearables, with the Apple Watch generally providing the best results compared with peers, despite overestimation. Heart rate variability measurements were found to have gaps in data but were able to detect mild mental stress. Activity monitoring with step counting showed good agreement, although wheelchair use was found to be prone to overestimation and poor performance on overground tasks. Atrial fibrillation detection showed mixed results, in part because of a high inconclusive result rate, but may be useful for ongoing monitoring. No studies recorded validation of the Sleep app feature; however, accelerometer-based sleep monitoring showed high accuracy and sensitivity in detecting sleep. Conclusions: The results are encouraging regarding the application of the Apple Watch in mental health, particularly as heart rate variability is a key indicator of changes in both physical and emotional states. Particular benefits may be derived through avoidance of recall bias and collection of supporting ecological context data. However, a lack of methodologically robust and replicated evidence of user benefit, a supportive health economic analysis, and concerns about personal health information remain key factors that must be addressed to enable broader uptake

    Imaging Sensors and Applications

    Get PDF
    In past decades, various sensor technologies have been used in all areas of our lives, thus improving our quality of life. In particular, imaging sensors have been widely applied in the development of various imaging approaches such as optical imaging, ultrasound imaging, X-ray imaging, and nuclear imaging, and contributed to achieve high sensitivity, miniaturization, and real-time imaging. These advanced image sensing technologies play an important role not only in the medical field but also in the industrial field. This Special Issue covers broad topics on imaging sensors and applications. The scope range of imaging sensors can be extended to novel imaging sensors and diverse imaging systems, including hardware and software advancements. Additionally, biomedical and nondestructive sensing applications are welcome

    Wearable and Nearable Biosensors and Systems for Healthcare

    Get PDF
    Biosensors and systems in the form of wearables and “nearables” (i.e., everyday sensorized objects with transmitting capabilities such as smartphones) are rapidly evolving for use in healthcare. Unlike conventional approaches, these technologies can enable seamless or on-demand physiological monitoring, anytime and anywhere. Such monitoring can help transform healthcare from the current reactive, one-size-fits-all, hospital-centered approach into a future proactive, personalized, decentralized structure. Wearable and nearable biosensors and systems have been made possible through integrated innovations in sensor design, electronics, data transmission, power management, and signal processing. Although much progress has been made in this field, many open challenges for the scientific community remain, especially for those applications requiring high accuracy. This book contains the 12 papers that constituted a recent Special Issue of Sensors sharing the same title. The aim of the initiative was to provide a collection of state-of-the-art investigations on wearables and nearables, in order to stimulate technological advances and the use of the technology to benefit healthcare. The topics covered by the book offer both depth and breadth pertaining to wearable and nearable technology. They include new biosensors and data transmission techniques, studies on accelerometers, signal processing, and cardiovascular monitoring, clinical applications, and validation of commercial devices

    Accuracy of heart rate variability estimated with reflective wrist-PPG in elderly vascular patients

    Get PDF
    Optical heart rate monitoring (OHR) with reflective wrist photoplethysmography is a technique mainly used in the wellness application domain for monitoring heart rate levels during exercise. In the absence of motion, OHR technique is also able to estimate individual beat‑to‑beat intervals relatively well and can therefore also be used, for example, in monitoring of cardiac arrhythmias, stress, or sleep quality through heart rate variability (HRV) analysis. HRV analysis has also potential in monitoring the recovery of patients, e.g. after a medical intervention. However, in order to detect subtle changes, the calculated HRV parameters should be sufficiently accurate and very few studies exist that asses the accuracy of OHR derived HRV in non‑healthy subjects. In this paper, we present a method to estimate beat‑to‑beat‑intervals (BBIs) from reflective wrist PPG signal and evaluated the accuracy of the proposed method in estimating BBIs in a cross‑sectional study with 29 hospitalized patients (mean age 70.6 years) in 24‑h recordings performed after peripheral vascular surgery or endovascular interventions. Finally, we evaluate the accuracy of more than 30 commonly used HRV parameters and find that the accuracy of certain metrics, for example SDNN and triangular index, shown in the literature to be associated with the deterioration of the status of the patients during recovery from surgical intervention, could be adequate for patient monitoring. On the other hand, the parameters more affected by the high‑frequency content of the HRV and especially the LF/HF‑ratio should be used with caution

    Continuous physical activity recording - Consumer-based activity trackers in epidemiological studies

    Get PDF
    Physical activity is an important modifiable lifestyle factor that can improve general health and reduce the risk of disease. Currently, collecting data on physical activity in epidemiological studies are generally limited to long-term but self-reported and inaccurate physical activity questionnaires and/or using short-term but objective and more accurate accelerometers. Consumer-based activity trackers are designed for long-term objective data collection and can therefore potentially be used to close this gap. The objective of this dissertation was therefore to explore and develop new methods for collecting data on physical activity in epidemiological studies using consumer-based activity trackers. The four included papers apply different methods to explore the objective from multiple angles. Results includes an overview of how activity tracker sensor support has changed over time, recommendations when choosing an activity tracker model for future physical activity research, recommendations for increasing activity tracker wear time among participants in clinical studies, as well as knowledge about activity tracker validity and physical activity trends during the Norwegian COVID-19 lockdown in 2020. Finally, the dissertation describes a system for automatic and continuous data collection using consumer-based activity trackers from multiple providers. We show the usability of this system by accessing and analysing historic activity tracker data from participants who wore a tracker before-, during-, and after the COVID-19 lockdown period. The proposed system can be a valuable addition to existing methods for physical activity assessment by contributing to closing the above-mentioned method gap