20,628 research outputs found

    Real-time human ambulation, activity, and physiological monitoring:taxonomy of issues, techniques, applications, challenges and limitations

    Get PDF
    Automated methods of real-time, unobtrusive, human ambulation, activity, and wellness monitoring and data analysis using various algorithmic techniques have been subjects of intense research. The general aim is to devise effective means of addressing the demands of assisted living, rehabilitation, and clinical observation and assessment through sensor-based monitoring. The research studies have resulted in a large amount of literature. This paper presents a holistic articulation of the research studies and offers comprehensive insights along four main axes: distribution of existing studies; monitoring device framework and sensor types; data collection, processing and analysis; and applications, limitations and challenges. The aim is to present a systematic and most complete study of literature in the area in order to identify research gaps and prioritize future research directions

    Automated Home Oxygen Delivery for Patients with COPD and Respiratory Failure: A New Approach

    Get PDF
    Long-term oxygen therapy (LTOT) has become standard care for the treatment of patients with chronic obstructive pulmonary disease (COPD) and other severe hypoxemic lung diseases. The use of new portable O-2 concentrators (POC) in LTOT is being expanded. However, the issue of oxygen titration is not always properly addressed, since POCs rely on proper use by patients. The robustness of algorithms and the limited reliability of current oximetry sensors are hindering the effectiveness of new approaches to closed-loop POCs based on the feedback of blood oxygen saturation. In this study, a novel intelligent portable oxygen concentrator (iPOC) is described. The presented iPOC is capable of adjusting the O-2 flow automatically by real-time classifying the intensity of a patient's physical activity (PA). It was designed with a group of patients with COPD and stable chronic respiratory failure. The technical pilot test showed a weighted accuracy of 91.1% in updating the O-2 flow automatically according to medical prescriptions, and a general improvement in oxygenation compared to conventional POCs. In addition, the usability achieved was high, which indicated a significant degree of user satisfaction. This iPOC may have important benefits, including improved oxygenation, increased compliance with therapy recommendations, and the promotion of PA

    Aerospace Medicine and Biology: A continuing supplement 180, May 1978

    Get PDF
    This special bibliography lists 201 reports, articles, and other documents introduced into the NASA scientific and technical information system in April 1978

    Examining adherence to activity monitoring devices to improve physical activity in adults with cardiovascular disease: A systematic review

    Get PDF
    Background Activity monitoring devices are currently being used to facilitate and monitor physical activity. No prior review has examined adherence to the use of activity monitoring devices amongst adults with cardiovascular disease. Methods Literature from June 2012 to October 2017 was evaluated to examine the extent of adherence to any activity monitoring device used to collect objective physical activity data. Randomized control trials comparing usual care against the use of an activity monitoring device, in a community intervention for adults from any cardiovascular diagnostic group, were included. A systematic search of databases and clinical trials registers was conducted using Joanna Briggs Institute methodology. Results Of 10 eligible studies, two studies reported pedometer use and eight accelerometer use. Six studies addressed the primary outcome. Mean adherence was 59.1% (range 39.6% to 85.7%) at last follow-up. Studies lacked equal representation by gender (28.6% female) and age (range 42 to 82 years). Conclusion This review indicates that current research on activity monitoring devices may be overstated due to the variability in adherence. Results showed that physical activity tracking in women and in young adults have been understudied

    Research progress on wearable devices for daily human health management

    Get PDF
    As the public’s demand for portable access to personal health information continues to expand, wearable devices are not only widely used in clinical practice, but also gradually applied to the daily health management of ordinary families due to their intelligence, miniaturization, and portability. This paper searches the literature of wearable devices through PubMed and CNKI databases, classifies them according to the different functions realized by wearable devices, and briefly describes the algorithms and specific analysis methods of their applications and made a prospect of its development trend in the field of human health

    The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings.

    Get PDF
    MotionSense HRV is a wrist-worn accelerometery-based sensor that is paired with a smartphone and is thus capable of measuring the intensity, duration, and frequency of physical activity (PA). However, little information is available on the validity of the MotionSense HRV. Therefore, the purpose of this study was to assess the concurrent validity of the MotionSense HRV in estimating sedentary behavior (SED) and PA. A total of 20 healthy adults (age: 32.5 ± 15.1 years) wore the MotionSense HRV and ActiGraph GT9X accelerometer (GT9X) on their non-dominant wrist for seven consecutive days during free-living conditions. Raw acceleration data from the devices were summarized into average time (min/day) spent in SED and moderate-to-vigorous PA (MVPA). Additionally, using the Cosemed K5 indirect calorimetry system (K5) as a criterion measure, the validity of the MotionSense HRV was examined in simulated free-living conditions. Pearson correlations, mean absolute percent errors (MAPE), Bland-Altman (BA) plots, and equivalence tests were used to examine the validity of the MotionSense HRV against criterion measures. The correlations between the MotionSense HRV and GT9X were high and the MAPE were low for both the SED (r = 0.99, MAPE = 2.4%) and MVPA (r = 0.97, MAPE = 9.1%) estimates under free-living conditions. BA plots illustrated that there was no systematic bias between the MotionSense HRV and criterion measures. The estimates of SED and MVPA from the MotionSense HRV were significantly equivalent to those from the GT9X; the equivalence zones were set at 16.5% for SED and 29% for MVPA. The estimates of SED and PA from the MotionSense HRV were less comparable when compared with those from the K5. The MotionSense HRV yielded comparable estimates for SED and PA when compared with the GT9X accelerometer under free-living conditions. We confirmed the promising application of the MotionSense HRV for monitoring PA patterns for practical and research purposes
    • …
    corecore