1,843 research outputs found
State-of-the art of acousto-optic sensing and imaging of turbid media
Acousto-optic (AO) is an emerging hybrid technique for measuring optical contrast in turbid media using coherent light and ultrasound (US). A turbid object is illuminated with a coherent light source leading to speckle formation in the remitted light. With the use of US, a small volume is selected,which is commonly referred to as the “tagging” volume. This volume acts as a source of modulated light, where modulation might involve phase and intensity change. The tagging volume is created by focusing ultrasound for good lateral resolution; the axial resolution is accomplished by making either the US frequency, amplitude, or phase time-dependent. Typical resolutions are in the order of 1 mm. We will concentrate on the progress in the field since 2003. Different schemes will be discussed to detect the modulated photons based on speckle detection, heterodyne detection, photorefractive crystal (PRC) assisted detection, and spectral hole burning (SHB) as well as Fabry-Perot interferometers. The SHB and Fabry-Perot interferometer techniques are insensitive to speckle decorrelation and therefore suitable for in vivo imaging. However, heterodyne and PRC methods also have potential for in vivo measurements. Besides measuring optical properties such as scattering and absorption, AO can be applied in fluorescence and elastography applications
Beyond backscattering: Optical neuroimaging by BRAD
Optical coherence tomography (OCT) is a powerful technology for rapid
volumetric imaging in biomedicine. The bright field imaging approach of
conventional OCT systems is based on the detection of directly backscattered
light, thereby waiving the wealth of information contained in the angular
scattering distribution. Here we demonstrate that the unique features of
few-mode fibers (FMF) enable simultaneous bright and dark field (BRAD) imaging
for OCT. As backscattered light is picked up by the different modes of a FMF
depending upon the angular scattering pattern, we obtain access to the
directional scattering signatures of different tissues by decoupling
illumination and detection paths. We exploit the distinct modal propagation
properties of the FMF in concert with the long coherence lengths provided by
modern wavelength-swept lasers to achieve multiplexing of the different modal
responses into a combined OCT tomogram. We demonstrate BRAD sensing for
distinguishing differently sized microparticles and showcase the performance of
BRAD-OCT imaging with enhanced contrast for ex vivo tumorous tissue in
glioblastoma and neuritic plaques in Alzheimer's disease
The Use of Optical Coherence Tomography in Dental Diagnostics: a State-of-the-Art Review
Optical coherence tomography provides sections of tissues in a noncontact and noninvasive manner. The device measures the time delay and intensity of the light scattered or reflected from biological tissues, which results in tomographic imaging of their internal structure. This is achieved by scanning tissues at a resolution ranging from 1 to 15 μm. OCT enables real-time in situ imaging of tissues without the need for biopsy, histological procedures, or the use of X-rays, so it can be used in many fields of medicine. Its properties are not only particularly used in ophthalmology, in the diagnosis of all layers of the retina, but also increasingly in cardiology, gastroenterology, pulmonology, oncology, and dermatology. The basic properties of OCT, that is, noninvasiveness and low wattage of the used light, have also been appreciated in analytical technology by conservators, who use it to identify the quality and age of paintings, ceramics, or glass. Recently, the OCT technique of visualization is being tested in different fields of dentistry, which is depicted in the article
Optical Coherence Tomography guided Laser-Cochleostomy
Despite the high precision of laser, it remains challenging to control the laser-bone ablation without injuring the underlying critical structures. Providing an axial resolution on micrometre scale, OCT is a promising candidate for imaging microstructures beneath the bone surface and monitoring the ablation process. In this work, a bridge connecting these two technologies is established. A closed-loop control of laser-bone ablation under the monitoring with OCT has been successfully realised
Parametric imaging of attenuation by optical coherence tomography: review of models, methods, and clinical translation
SIGNIFICANCE: Optical coherence tomography (OCT) provides cross-sectional and volumetric images of backscattering from biological tissue that reveal the tissue morphology. The strength of the scattering, characterized by an attenuation coefficient, represents an alternative and complementary tissue optical property, which can be characterized by parametric imaging of the OCT attenuation coefficient. Over the last 15 years, a multitude of studies have been reported seeking to advance methods to determine the OCT attenuation coefficient and developing them toward clinical applications. AIM: Our review provides an overview of the main models and methods, their assumptions and applicability, together with a survey of preclinical and clinical demonstrations and their translation potential. RESULTS: The use of the attenuation coefficient, particularly when presented in the form of parametric en face images, is shown to be applicable in various medical fields. Most studies show the promise of the OCT attenuation coefficient in differentiating between tissues of clinical interest but vary widely in approach. CONCLUSIONS: As a future step, a consensus on the model and method used for the determination of the attenuation coefficient is an important precursor to large-scale studies. With our review, we hope to provide a basis for discussion toward establishing this consensus
Quantitative micro-elastography: imaging of tissue elasticity using compression optical coherence elastography
Probing the mechanical properties of tissue on the microscale could aid in the identification of diseased tissues that are inadequately detected using palpation or current clinical imaging modalities, with potential to guide medical procedures such as the excision of breast tumours. Compression optical coherence elastography (OCE) maps tissue strain with microscale spatial resolution and can delineate microstructural features within breast tissues. However, without a measure of the locally applied stress, strain provides only a qualitative indication of mechanical properties. To overcome this limitation, we present quantitative micro-elastography, which combines compression OCE with a compliant stress sensor to image tissue elasticity. The sensor consists of a layer of translucent silicone with well-characterized stress-strain behaviour. The measured strain in the sensor is used to estimate the two-dimensional stress distribution applied to the sample surface. Elasticity is determined by dividing the stress by the strain in the sample. We show that quantification of elasticity can improve the ability of compression OCE to distinguish between tissues, thereby extending the potential for inter-sample comparison and longitudinal studies of tissue elasticity. We validate the technique using tissue-mimicking phantoms and demonstrate the ability to map elasticity of freshly excised malignant and benign human breast tissues.Kelsey M. Kennedy, Lixin Chin, Robert A. McLaughlin, Bruce Latham, Christobel M. Saunders, David D. Sampson and Brendan F. Kenned
Endoscopic Optical Coherence Tomography: Design and Application
This thesis presents an investigation on endoscopic optical coherence tomography (OCT). As a noninvasive imaging modality, OCT emerges as an increasingly important diagnostic tool for many clinical applications. Despite of many of its merits, such as high resolution and depth resolvability, a major limitation is the relatively shallow penetration depth in tissue (about 2∼3 mm). This is mainly due to tissue scattering and absorption. To overcome this limitation, people have been developing many different endoscopic OCT systems. By utilizing a minimally invasive endoscope, the OCT probing beam can be brought to the close vicinity of the tissue of interest and bypass the scattering of intervening tissues so that it can collect the reflected light signal from desired depth and provide a clear image representing the physiological structure of the region, which can not be disclosed by traditional OCT. In this thesis, three endoscope designs have been studied. While they rely on vastly different principles, they all converge to solve this long-standing problem.
A hand-held endoscope with manual scanning is first explored. When a user is holding a hand- held endoscope to examine samples, the movement of the device provides a natural scanning. We proposed and implemented an optical tracking system to estimate and record the trajectory of the device. By registering the OCT axial scan with the spatial information obtained from the tracking system, one can use this system to simply ‘paint’ a desired volume and get any arbitrary scanning pattern by manually waving the endoscope over the region of interest. The accuracy of the tracking system was measured to be about 10 microns, which is comparable to the lateral resolution of most OCT system. Targeted phantom sample and biological samples were manually scanned and the reconstructed images verified the method.
Next, we investigated a mechanical way to steer the beam in an OCT endoscope, which is termed as Paired-angle-rotation scanning (PARS). This concept was proposed by my colleague and we further developed this technology by enhancing the longevity of the device, reducing the diameter of the probe, and shrinking down the form factor of the hand-piece. Several families of probes have been designed and fabricated with various optical performances. They have been applied to different applications, including the collector channel examination for glaucoma stent implantation, and vitreous remnant detection during live animal vitrectomy.
Lastly a novel non-moving scanning method has been devised. This approach is based on the EO effect of a KTN crystal. With Ohmic contact of the electrodes, the KTN crystal can exhibit a special mode of EO effect, termed as space-charge-controlled electro-optic effect, where the carrier electron will be injected into the material via the Ohmic contact. By applying a high voltage across the material, a linear phase profile can be built under this mode, which in turn deflects the light beam passing through. We constructed a relay telescope to adapt the KTN deflector into a bench top OCT scanning system. One of major technical challenges for this system is the strong chromatic dispersion of KTN crystal within the wavelength band of OCT system. We investigated its impact on the acquired OCT images and proposed a new approach to estimate and compensate the actual dispersion. Comparing with traditional methods, the new method is more computational efficient and accurate. Some biological samples were scanned by this KTN based system. The acquired images justified the feasibility of the usage of this system into a endoscopy setting.
My research above all aims to provide solutions to implement an OCT endoscope. As technology evolves from manual, to mechanical, and to electrical approaches, different solutions are presented. Since all have their own advantages and disadvantages, one has to determine the actual requirements and select the best fit for a specific application.</p
Recommended from our members
Design and development of optical reflectance spectroscopy and optical coherence tomography catheters for myocardial tissue characterization
Catheter ablation therapy attempts to restore sinus rhythm in arrhythmia patients by producing site-specific tissue modification along regions which cause abnormal electrical activity. This treatment, though widely used, often requires repeat procedures to observe long-term therapeutic benefits. This limitation is driven in part by challenges faced by conventional schemes in validating lesion adequacy at the time of the procedure. Optical techniques are well-suited for the interrogation and characterization of biological tissues. In particular, optical coherence tomography (OCT) relies on coherence gating of singly-scattered light to enable high-resolution structural imaging for tissue diagnostics and procedural guidance. Alternatively, optical reflectance spectroscopy (ORS) is a point measurement technique which makes use of incoherent, multiply-scattered light to probe tissue volumes and derive important data from its optical signature. ORS relies on the fact that light-tissue interactions are regulated by absorption and scattering, which directly relate to the intrinsic tissue biochemistry and cellular organization. In this thesis, we explore the integration of these modalities into ablation catheters for obtaining procedural metrics which could be utilized to guide catheter ablation therapy. We first present the development of an accelerated computational light transport model and its application for guiding ORS catheter design. A custom ORS-integrated ablation catheter is then implemented and tested within porcine specimens in vitro. A model is proposed for real-time estimation of lesion size based on changes in spectral morphology acquired during ablation. We then fabricated custom integrated OCT M-mode RF catheters and present a model for detecting contact status based on deep convolutional neural networks trained on endomyocardial images. Additionally, we demonstrate for the first time, tracking of RF-induced lesion formation employing OCT Doppler micro-velocimetry; this response is shown to be commensurate with the degree of treatment. We further demonstrate for the first time spectroscopic tracking of kinetics related to the heme oxidation cascade during thermal treatment, which are linked to tissue denaturation. The pairing of these modalities into a single RF catheter was also validated for guiding lesion delivery in vitro and within live pigs. Finally, we conclude with a proof-of-concept demonstration of ORS as a mapping tool to guide epicardial ablation in human donor hearts. These results showcase the vast potential of ORS and OCT empowered RF catheters for aiding intraprocedural guidance of catheter ablation procedures which could be utilized alongside current practices
- …