587 research outputs found

    A spectral reflectance estimation technique using multispectral data from the Viking lander camera

    Get PDF
    A technique is formulated for constructing spectral reflectance curve estimates from multispectral data obtained with the Viking lander camera. The multispectral data are limited to six spectral channels in the wavelength range from 0.4 to 1.1 micrometers and most of these channels exhibit appreciable out-of-band response. The output of each channel is expressed as a linear (integral) function of the (known) solar irradiance, atmospheric transmittance, and camera spectral responsivity and the (unknown) spectral responsivity and the (unknown) spectral reflectance. This produces six equations which are used to determine the coefficients in a representation of the spectral reflectance as a linear combination of known basis functions. Natural cubic spline reflectance estimates are produced for a variety of materials that can be reasonably expected to occur on Mars. In each case the dominant reflectance features are accurately reproduced, but small period features are lost due to the limited number of channels. This technique may be a valuable aid in selecting the number of spectral channels and their responsivity shapes when designing a multispectral imaging system

    Digital Color Imaging

    Full text link
    This paper surveys current technology and research in the area of digital color imaging. In order to establish the background and lay down terminology, fundamental concepts of color perception and measurement are first presented us-ing vector-space notation and terminology. Present-day color recording and reproduction systems are reviewed along with the common mathematical models used for representing these devices. Algorithms for processing color images for display and communication are surveyed, and a forecast of research trends is attempted. An extensive bibliography is provided

    Structure-Preserving Spectral Reflectance Estimation using Guided Filtering

    Full text link
    Light spectra are a very important source of information for diverse classification problems, e.g., for discrimination of materials. To lower the cost for acquiring this information, multispectral cameras are used. Several techniques exist for estimating light spectra out of multispectral images by exploiting properties about the spectrum. Unfortunately, especially when capturing multispectral videos, the images are heavily affected by noise due to the nature of limited exposure times in videos. Therefore, models that explicitly try to lower the influence of noise on the reconstructed spectrum are highly desirable. Hence, a novel reconstruction algorithm is presented. This novel estimation method is based on the guided filtering technique which preserves basic structures, while using spatial information to reduce the influence of noise. The evaluation based on spectra of natural images reveals that this new technique yields better quantitative and subjective results in noisy scenarios than other state-of-the-art spatial reconstruction methods. Specifically, the proposed algorithm lowers the mean squared error and the spectral angle up to 46% and 35% in noisy scenarios, respectively. Furthermore, it is shown that the proposed reconstruction technique works out-of-the-box and does not need any calibration or training by reconstructing spectra from a real-world multispectral camera with nine channels

    Algorithms for the enhancement of dynamic range and colour constancy of digital images & video

    Get PDF
    One of the main objectives in digital imaging is to mimic the capabilities of the human eye, and perhaps, go beyond in certain aspects. However, the human visual system is so versatile, complex, and only partially understood that no up-to-date imaging technology has been able to accurately reproduce the capabilities of the it. The extraordinary capabilities of the human eye have become a crucial shortcoming in digital imaging, since digital photography, video recording, and computer vision applications have continued to demand more realistic and accurate imaging reproduction and analytic capabilities. Over decades, researchers have tried to solve the colour constancy problem, as well as extending the dynamic range of digital imaging devices by proposing a number of algorithms and instrumentation approaches. Nevertheless, no unique solution has been identified; this is partially due to the wide range of computer vision applications that require colour constancy and high dynamic range imaging, and the complexity of the human visual system to achieve effective colour constancy and dynamic range capabilities. The aim of the research presented in this thesis is to enhance the overall image quality within an image signal processor of digital cameras by achieving colour constancy and extending dynamic range capabilities. This is achieved by developing a set of advanced image-processing algorithms that are robust to a number of practical challenges and feasible to be implemented within an image signal processor used in consumer electronics imaging devises. The experiments conducted in this research show that the proposed algorithms supersede state-of-the-art methods in the fields of dynamic range and colour constancy. Moreover, this unique set of image processing algorithms show that if they are used within an image signal processor, they enable digital camera devices to mimic the human visual system s dynamic range and colour constancy capabilities; the ultimate goal of any state-of-the-art technique, or commercial imaging device

    Multispectral image analysis in laparoscopy – A machine learning approach to live perfusion monitoring

    Get PDF
    Modern visceral surgery is often performed through small incisions. Compared to open surgery, these minimally invasive interventions result in smaller scars, fewer complications and a quicker recovery. While to the patients benefit, it has the drawback of limiting the physician’s perception largely to that of visual feedback through a camera mounted on a rod lens: the laparoscope. Conventional laparoscopes are limited by “imitating” the human eye. Multispectral cameras remove this arbitrary restriction of recording only red, green and blue colors. Instead, they capture many specific bands of light. Although these could help characterize important indications such as ischemia and early stage adenoma, the lack of powerful digital image processing prevents realizing the technique’s full potential. The primary objective of this thesis was to pioneer fluent functional multispectral imaging (MSI) in laparoscopy. The main technical obstacles were: (1) The lack of image analysis concepts that provide both high accuracy and speed. (2) Multispectral image recording is slow, typically ranging from seconds to minutes. (3) Obtaining a quantitative ground truth for the measurements is hard or even impossible. To overcome these hurdles and enable functional laparoscopy, for the first time in this field physical models are combined with powerful machine learning techniques. The physical model is employed to create highly accurate simulations, which in turn teach the algorithm to rapidly relate multispectral pixels to underlying functional changes. To reduce the domain shift introduced by learning from simulations, a novel transfer learning approach automatically adapts generic simulations to match almost arbitrary recordings of visceral tissue. In combination with the only available video-rate capable multispectral sensor, the method pioneers fluent perfusion monitoring with MSI. This system was carefully tested in a multistage process, involving in silico quantitative evaluations, tissue phantoms and a porcine study. Clinical applicability was ensured through in-patient recordings in the context of partial nephrectomy; in these, the novel system characterized ischemia live during the intervention. Verified against a fluorescence reference, the results indicate that fluent, non-invasive ischemia detection and monitoring is now possible. In conclusion, this thesis presents the first multispectral laparoscope capable of videorate functional analysis. The system was successfully evaluated in in-patient trials, and future work should be directed towards evaluation of the system in a larger study. Due to the broad applicability and the large potential clinical benefit of the presented functional estimation approach, I am confident the descendants of this system are an integral part of the next generation OR

    NeuralMPS: Non-Lambertian Multispectral Photometric Stereo via Spectral Reflectance Decomposition

    Full text link
    Multispectral photometric stereo(MPS) aims at recovering the surface normal of a scene from a single-shot multispectral image captured under multispectral illuminations. Existing MPS methods adopt the Lambertian reflectance model to make the problem tractable, but it greatly limits their application to real-world surfaces. In this paper, we propose a deep neural network named NeuralMPS to solve the MPS problem under general non-Lambertian spectral reflectances. Specifically, we present a spectral reflectance decomposition(SRD) model to disentangle the spectral reflectance into geometric components and spectral components. With this decomposition, we show that the MPS problem for surfaces with a uniform material is equivalent to the conventional photometric stereo(CPS) with unknown light intensities. In this way, NeuralMPS reduces the difficulty of the non-Lambertian MPS problem by leveraging the well-studied non-Lambertian CPS methods. Experiments on both synthetic and real-world scenes demonstrate the effectiveness of our method

    Multifocus HDR VIS/NIR hyperspectral imaging and its application to works of art

    Get PDF
    The authors would like to thank Mr. Francisco Fernández Fábregas, owner of the Transfiguration of Christ for allowing us the privilege of studying this painting. We also acknowledge the collaboration of Angela Tate.This paper presents a complete framework for capturing and processing hyperspectral reflectance images of artworks in situ, using a hyperspectral line scanner. These capturing systems are commonly used in laboratory conditions synchronized with scanning stages specifically designed for planar surfaces. However, when the intended application domain does not allow for image capture in these controlled conditions, achieving useful spectral reflectance image data can be a very challenging task (due to uncontrolled illumination, high-dynamic range (HDR) conditions in the scene, and the influence of chromatic aberration on the image quality, among other factors). We show, for the first time, all the necessary steps in the image capturing and post-processing in order to obtain high-quality HDR-based reflectance in the visible and near infrared, directly from the data captured by using a hyperspectral line scanner coupled to a rotating tripod. Our results show that the proposed method outperforms the normal capturing process in terms of dynamic range, color and spectral accuracy. To demonstrate the potential interest of this processing strategy for on-site analysis of artworks, we applied it to the study of a vintage copy of the famous painting “Transfiguration” by Raphael, as well as a facsimile of “The Golden Haggadah” from the British Library of London. The second piece has been studied for the identification of highly reflective gold-foil covered areas.Spanish Ministry of Economy and Competitiveness, DPI2015-64571-R, ECQM2018-004952-

    Translational Functional Imaging in Surgery Enabled by Deep Learning

    Get PDF
    Many clinical applications currently rely on several imaging modalities such as Positron Emission Tomography (PET), Magnetic Resonance Imaging (MRI), Computed Tomography (CT), etc. All such modalities provide valuable patient data to the clinical staff to aid clinical decision-making and patient care. Despite the undeniable success of such modalities, most of them are limited to preoperative scans and focus on morphology analysis, e.g. tumor segmentation, radiation treatment planning, anomaly detection, etc. Even though the assessment of different functional properties such as perfusion is crucial in many surgical procedures, it remains highly challenging via simple visual inspection. Functional imaging techniques such as Spectral Imaging (SI) link the unique optical properties of different tissue types with metabolism changes, blood flow, chemical composition, etc. As such, SI is capable of providing much richer information that can improve patient treatment and care. In particular, perfusion assessment with functional imaging has become more relevant due to its involvement in the treatment and development of several diseases such as cardiovascular diseases. Current clinical practice relies on Indocyanine Green (ICG) injection to assess perfusion. Unfortunately, this method can only be used once per surgery and has been shown to trigger deadly complications in some patients (e.g. anaphylactic shock). This thesis addressed common roadblocks in the path to translating optical functional imaging modalities to clinical practice. The main challenges that were tackled are related to a) the slow recording and processing speed that SI devices suffer from, b) the errors introduced in functional parameter estimations under changing illumination conditions, c) the lack of medical data, and d) the high tissue inter-patient heterogeneity that is commonly overlooked. This framework follows a natural path to translation that starts with hardware optimization. To overcome the limitation that the lack of labeled clinical data and current slow SI devices impose, a domain- and task-specific band selection component was introduced. The implementation of such component resulted in a reduction of the amount of data needed to monitor perfusion. Moreover, this method leverages large amounts of synthetic data, which paired with unlabeled in vivo data is capable of generating highly accurate simulations of a wide range of domains. This approach was validated in vivo in a head and neck rat model, and showed higher oxygenation contrast between normal and cancerous tissue, in comparison to a baseline using all available bands. The need for translation to open surgical procedures was met by the implementation of an automatic light source estimation component. This method extracts specular reflections from low exposure spectral images, and processes them to obtain an estimate of the light source spectrum that generated such reflections. The benefits of light source estimation were demonstrated in silico, in ex vivo pig liver, and in vivo human lips, where the oxygenation estimation error was reduced when utilizing the correct light source estimated with this method. These experiments also showed that the performance of the approach proposed in this thesis surpass the performance of other baseline approaches. Video-rate functional property estimation was achieved by two main components: a regression and an Out-of-Distribution (OoD) component. At the core of both components is a compact SI camera that is paired with state-of-the-art deep learning models to achieve real time functional estimations. The first of such components features a deep learning model based on a Convolutional Neural Network (CNN) architecture that was trained on highly accurate physics-based simulations of light-tissue interactions. By doing this, the challenge of lack of in vivo labeled data was overcome. This approach was validated in the task of perfusion monitoring in pig brain and in a clinical study involving human skin. It was shown that this approach is capable of monitoring subtle perfusion changes in human skin in an arm clamping experiment. Even more, this approach was capable of monitoring Spreading Depolarizations (SDs) (deoxygenation waves) in the surface of a pig brain. Even though this method is well suited for perfusion monitoring in domains that are well represented with the physics-based simulations on which it was trained, its performance cannot be guaranteed for outlier domains. To handle outlier domains, the task of ischemia monitoring was rephrased as an OoD detection task. This new functional estimation component comprises an ensemble of Invertible Neural Networks (INNs) that only requires perfused tissue data from individual patients to detect ischemic tissue as outliers. The first ever clinical study involving a video-rate capable SI camera in laparoscopic partial nephrectomy was designed to validate this approach. Such study revealed particularly high inter-patient tissue heterogeneity under the presence of pathologies (cancer). Moreover, it demonstrated that this personalized approach is now capable of monitoring ischemia at video-rate with SI during laparoscopic surgery. In conclusion, this thesis addressed challenges related to slow image recording and processing during surgery. It also proposed a method for light source estimation to facilitate translation to open surgical procedures. Moreover, the methodology proposed in this thesis was validated in a wide range of domains: in silico, rat head and neck, pig liver and brain, and human skin and kidney. In particular, the first clinical trial with spectral imaging in minimally invasive surgery demonstrated that video-rate ischemia monitoring is now possible with deep learning

    Global crop production forecasting data system analysis

    Get PDF
    The author has identified the following significant results. Findings led to the development of a theory of radiometric discrimination employing the mathematical framework of the theory of discrimination between scintillating radar targets. The theory indicated that the functions which drive accuracy of discrimination are the contrast ratio between targets, and the number of samples, or pixels, observed. Theoretical results led to three primary consequences, as regards the data system: (1) agricultural targets must be imaged at correctly chosen times, when the relative evolution of the crop's development is such as to maximize their contrast; (2) under these favorable conditions, the number of observed pixels can be significantly reduced with respect to wall-to-wall measurements; and (3) remotely sensed radiometric data must be suitably mixed with other auxiliary data, derived from external sources
    corecore