196 research outputs found

    Faraday Rotation Correction for Passive Microwave Remote Sensing from Space

    Get PDF
    Faraday rotation (FR) is one of the main error sources for passive microwave remote sensing from space especially in frequencies less than or equal to 10.7 GHz. In this paper, Faraday rotation correction for the vertical brightness temperature at L band and the third Stokes parameter brightness temperature at 10.7 GHz are discussed. Two approaches are studied to remove the influence of FR: correction by auxiliary data and correction by polarimetric mode. At 1.4 GHz, correction by polarimetric mode performs better than correction by auxiliary data. At 10.7 GHz, correction by auxiliary data is feasible while polarimetric mode correction becomes invalid. We propose a new method of using TEC data released by international GNSS service (IGS) for correction. It has been proved that the residual correction errors are reduced. IGS data method greatly improves the correction accuracy

    Measuring GNSS ionospheric total electron content at Concordia, and application to L-band radiometers

    Get PDF
    In the framework of the project BIS - Bipolar Ionospheric Scintillation and Total Electron Content Monitoring, the ISACCO-DMC0 and ISACCO-DMC1 permanent monitoring stations were installed in 2008. The principal scope of the stations is to measure the ionospheric total electron content (TEC) and to monitor the ionospheric scintillations, using high-sampling-frequency global positioning system (GPS) ionospheric scintillation and TEC monitor (GISTM) receivers. The disturbances that the ionosphere can induce on the electromagnetic signals emitted by the Global Navigation Satellite System constellations are due to the presence of electron density anomalies in the ionosphere, which are particularly frequent at high latitudes, where the upper atmosphere is highly sensitive to perturbations coming from outer space. With the development of present and future low-frequency space-borne microwave missions (e.g., Soil Moisture and Ocean Salinity [SMOS], Aquarius, and Soil Moisture Active Passive missions), there is an increasing need to estimate the effects of the ionosphere on the propagation of electromagnetic waves that affects satellite measurements. As an example, how the TEC data collected at Concordia station are useful for the calibration of the European Space Agency SMOS data within the framework of an experiment promoted by the European Space Agency (known as DOMEX) will be discussed. The present report shows the ability of the GISTM station to monitor ionospheric scintillation and TEC, which indicates that only the use of continuous GPS measurements can provide accurate information on TEC variability, which is necessary for continuous calibration of satellite data

    Soil Moisture ActivePassive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration

    Get PDF
    The SMAP microwave radiometer is a fully-polarimetric L-band radiometer flown on the SMAP satellite in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude. Since April, 2015, the radiometer is under calibration and validation to assess the quality of the radiometer L1B data product. Calibration methods including the SMAP L1B TA2TB (from Antenna Temperature (TA) to the Earths surface Brightness Temperature (TB)) algorithm and TA forward models are outlined, and validation approaches to calibration stability/quality are described in this paper including future work. Results show that the current radiometer L1B data satisfies its requirements

    SMAP L-Band Microwave Radiometer: Instrument Design and First Year on Orbit

    Get PDF
    The Soil Moisture Active Passive (SMAP) L-band microwave radiometer is a conical scanning instrument designed to measure soil moisture with 4 percent volumetric accuracy at 40-kilometer spatial resolution. SMAP is NASA's first Earth Systematic Mission developed in response to its first Earth science decadal survey. Here, the design is reviewed and the results of its first year on orbit are presented. Unique features of radiometer include a large 6-meter rotating reflector, fully polarimetric radiometer receiver with internal calibration, and radio-frequency interference detection and filtering hardware. The radiometer electronics are thermally controlled to achieve good radiometric stability. Analyses of on-orbit results indicate the electrical and thermal characteristics of the electronics and internal calibration sources are very stable and promote excellent gain stability. Radiometer NEdT (Noise Equivalent differential Temperature) less than 1 degree Kelvin for 17-millisecond samples. The gain spectrum exhibits low noise at frequencies greater than 1 megahertz and 1 divided by f (pink) noise rising at longer time scales fully captured by the internal calibration scheme. Results from sky observations and global swath imagery of all four Stokes antenna temperatures indicate the instrument is operating as expected

    The Influence of Antenna Pattern on Faraday Rotation in Remote Sensing at L-band

    Get PDF
    Faraday rotation is a change in the polarization vector of electromagnetic radiation that occurs as the waves propagate from the Earth surface through the ionosphere to a spaceborne sensor. This change can cause errors in monitoring parameters at the surface such as soil moisture and sea surface salinity and it is an important consideration for radiometers on future missions in space such as NASA's Aquarius mission and ESA's SMOS mission. Two prominent strategies for compensating for Faraday rotation are using a sum of the signal at two polarizations and using the correlation between the signals at the two polarizations. These strategies work for an idealized antenna. This paper evaluates the strategies in the context of realistic antennas such as will be built for the Aquarius radiometer. Realistic antennas will make small differences that need to be included in planning for retrieval algorithms in future missions

    Aquarius Radiometer Status

    Get PDF
    Aquarius was launched on June 10, 2011 as part of the Aquarius/SAC-D observatory and the instrument has been operating continuously since being turned on in August of the same year. The initial map of sea surface salinity was released one month later (September) and the quality of the retrieval has continuously improved since then. The Aquarius radiometers include several special features such as measurement of the third Stokes parameter, fast sampling, and careful thermal control, and a combined passive/active instrument. Aquarius is working well and in addition to helping measure salinity, the radiometer special features are generating new results

    Aquarius Overview and Up Date

    Get PDF
    Aquarius is an L-band instrument designed to map the surface salinity field of the global oceans. It consists of three L-band (1.41 GHz) radiometers and an L-band (1.26 GHz) scatterometer. The radiometers are the primary instruments for measuring salinity and the scatterometer provides a correction for surface roughness. Aquarius was launched in June 2011 and has been mapping the surface salinity field since it was turned on in August. In addition, Aquarius is now producing maps of radio frequency interference (RFI), Faraday rotation and soil moisture

    Aquarius Mission Technical Overview

    Get PDF
    Aquarius is an L-band microwave instrument being developed to map the surface salinity field of the oceans from space. It is part of the Aquarius/SAC-D mission, a partnership between the USA (NASA) and Argentina (CONAE) with launch scheduled for early in 2009. The primary science objective of this mission is to monitor the seasonal and interannual variation of the large scale features of the surface salinity field in the open ocean with a spatial resolution of 150 km and a retrieval accuracy of 0.2 psu globally on a monthly basis

    Aquarius and Remote Sensing of Sea Surface Salinity from Space

    Get PDF
    Aquarius is an L-band radiometer and scatterometer instrument combination designed to map the salinity field at the surface of the ocean from space. The instrument is designed to provide global salinity maps on a monthly basis with a spatial resolution of 150 km and an accuracy of 0.2 psu. The science objective is to monitor the seasonal and interannual variation of the large scale features of the surface salinity field in the open ocean. This data will promote understanding of ocean circulation and its role in the global water cycle and climate

    Correcting the FRA systematic error in VTEC maps from SMOS radiometric data

    Get PDF
    The Faraday rotation (FR) is a nonnegligible effect at the L-band, which is the operation frequency of the Soil Moisture and Ocean Salinity (SMOS) mission. This effect introduces a rotation in the electromagnetic field polarization when propagating through the ionosphere that must be compensated. Recently, a methodology was developed in order to retrieve the vertical total electron content (VTEC) from SMOS radiometric data with the aim to better correct the FR effect [1] . In that work, systematic patterns in the retrieved FR angle (FRA) were detected. In this article, these systematic patterns are characterized and corrected to improve the quality of the retrieved VTEC maps. These maps can be then reused in the SMOS level 2 processor for the correction of the FRA in the mission. The impact of using the SMOS-derived VTEC maps instead of the VTEC data from global positioning system (GPS) measurements on the ocean brightness temperatures (TB) measurement has also been analyzed. Results of this analysis show that the usage of those maps allows a significant enhancement in the quality of the TB, which will lead to an improvement on salinity retrievals.This work was supported in part by the European Space Agency, Soil Moisture and Ocean Salinity (SMOS) Expert Support Laboratories (ESL) for SMOS Level 1 and Level 2 over Land, Ocean and Ice Project under Grant RFQ/3-16138/19/I-BG; in part by the SMOS P7 under Contract DME CP12 no. 2015-005 (in joint with Deimos Engenharia, Portugal); in part by the Spanish Public Funds under Project TEC2017-88850-R and Project ESP2015-67549-C3-1-R through the Award “Unidad de Excelencia María de Maeztu” MDM-2016-0600, financed by the “Agencia Estatal de Investigación” (Spain); in part by the European Regional Development (ERDF); in part by the SMOS ESL for SMOS Level 1 and Level 2 over Land, Ocean and Ice Project under Grant ARG/003-032/0315/ICMCSIC; in part by the Spanish Research and Development Project INTERACT under Grant PID2020-114623RB-C31; and in part by the Spanish Government through the “Severo Ochoa Centre of Excellence” accreditation under Grant CEX2019-000928-S.Peer ReviewedPostprint (author's final draft
    • …
    corecore