4,040 research outputs found

    Fully Integrated Biochip Platforms for Advanced Healthcare

    Get PDF
    Recent advances in microelectronics and biosensors are enabling developments of innovative biochips for advanced healthcare by providing fully integrated platforms for continuous monitoring of a large set of human disease biomarkers. Continuous monitoring of several human metabolites can be addressed by using fully integrated and minimally invasive devices located in the sub-cutis, typically in the peritoneal region. This extends the techniques of continuous monitoring of glucose currently being pursued with diabetic patients. However, several issues have to be considered in order to succeed in developing fully integrated and minimally invasive implantable devices. These innovative devices require a high-degree of integration, minimal invasive surgery, long-term biocompatibility, security and privacy in data transmission, high reliability, high reproducibility, high specificity, low detection limit and high sensitivity. Recent advances in the field have already proposed possible solutions for several of these issues. The aim of the present paper is to present a broad spectrum of recent results and to propose future directions of development in order to obtain fully implantable systems for the continuous monitoring of the human metabolism in advanced healthcare applications

    Roadmap on semiconductor-cell biointerfaces.

    Get PDF
    This roadmap outlines the role semiconductor-based materials play in understanding the complex biophysical dynamics at multiple length scales, as well as the design and implementation of next-generation electronic, optoelectronic, and mechanical devices for biointerfaces. The roadmap emphasizes the advantages of semiconductor building blocks in interfacing, monitoring, and manipulating the activity of biological components, and discusses the possibility of using active semiconductor-cell interfaces for discovering new signaling processes in the biological world

    Design Of Dna Strand Displacement Based Circuits

    Get PDF
    DNA is the basic building block of any living organism. DNA is considered a popular candidate for future biological devices and circuits for solving genetic disorders and several other medical problems. With this objective in mind, this research aims at developing novel approaches for the design of DNA based circuits. There are many recent developments in the medical field such as the development of biological nanorobots, SMART drugs, and CRISPR-Cas9 technologies. There is a strong need for circuits that can work with these technologies and devices. DNA is considered a suitable candidate for designing such circuits because of the programmability of the DNA strands, small size, lightweight, known thermodynamics, higher parallelism, and exponentially reducing the cost of synthesizing techniques. The DNA strand displacement operation is useful in developing circuits with DNA strands. The circuit can be either a digital circuit, in which the logic high and logic low states of the DNA strand concentrations are considered as the signal, or it can be an analog circuit in which the concentration of the DNA strands itself will act as the signal. We developed novel approaches in this research for the design of digital, as well as analog circuits keeping in view of the number of DNA strands required for the circuit design. Towards this goal in the digital domain, we developed spatially localized DNA majority logic gates and an inverter logic gate that can be used with the existing seesaw based logic gates. The majority logic gates proposed in this research can considerably reduce the number of strands required in the design. The introduction of the logic inverter operation can translate the dual rail circuit architecture into a monorail architecture for the seesaw based logic circuits. It can also reduce the number of unique strands required for the design into approximately half. The reduction in the number of unique strands will consequently reduce the leakage reactions, circuit complexity, and cost associated with the DNA circuits. The real world biological inputs are analog in nature. If we can use those analog signals directly in the circuits, it can considerably reduce the resources required. Even though analog circuits are highly prone to noise, they are a perfect candidate for performing computations in the resource-limited environments, such as inside the cell. In the analog domain, we are developing a novel fuzzy inference engine using analog circuits such as the minimum gate, maximum gate, and fan-out gates. All the circuits discussed in this research were designed and tested in the Visual DSD software. The biological inputs are inherently fuzzy in nature, hence a fuzzy based system can play a vital role in future decision-making circuits. We hope that our research will be the first step towards realizing these larger goals. The ultimate aim of our research is to develop novel approaches for the design of circuits which can be used with the future biological devices to tackle many medical problems such as genetic disorders

    Timing molecular motion and production with a synthetic transcriptional clock

    Get PDF
    The realization of artificial biochemical reaction networks with unique functionality is one of the main challenges for the development of synthetic biology. Due to the reduced number of components, biochemical circuits constructed in vitro promise to be more amenable to systematic design and quantitative assessment than circuits embedded within living organisms. To make good on that promise, effective methods for composing subsystems into larger systems are needed. Here we used an artificial biochemical oscillator based on in vitro transcription and RNA degradation reactions to drive a variety of “load” processes such as the operation of a DNA-based nanomechanical device (“DNA tweezers”) or the production of a functional RNA molecule (an aptamer for malachite green). We implemented several mechanisms for coupling the load processes to the oscillator circuit and compared them based on how much the load affected the frequency and amplitude of the core oscillator, and how much of the load was effectively driven. Based on heuristic insights and computational modeling, an “insulator circuit” was developed, which strongly reduced the detrimental influence of the load on the oscillator circuit. Understanding how to design effective insulation between biochemical subsystems will be critical for the synthesis of larger and more complex systems
    corecore