328 research outputs found

    Enhanced teleoperation performance using hybrid control and virtual fixture

    Get PDF
    To develop secure, natural and effective teleoperation, the perception of the slave plays a key role for the interaction of a human operator with the environment. By sensing slave information, the human operator can choose the correct operation in a process during the human–robot interaction.This paper develops an integrated scheme based on a hybrid control and virtual fixture approach for the telerobot. The human operator can sense the slave interaction condition and adjust the master device via the surface electromyographic signal. This hybrid control method integrates the proportional-derivative control and the variable stiffness control, and involves the muscle activation at the same time. It is proposed to quantitatively analyse the human operator’s control demand to enhance the control performance of the teleoperation system. In addition, due to unskilful operation and muscle physiological tremor of the human operator, a virtual fixture method is developed to ensure accuracy of operation and to reduce the operation pressure on the human operator. Experimental results demonstrated the effectiveness of the proposed method for the teleoperated robot

    Development and evaluation of mixed reality-enhanced robotic systems for intuitive tele-manipulation and telemanufacturing tasks in hazardous conditions

    Get PDF
    In recent years, with the rapid development of space exploration, deep-sea discovery, nuclear rehabilitation and management, and robotic-assisted medical devices, there is an urgent need for humans to interactively control robotic systems to perform increasingly precise remote operations. The value of medical telerobotic applications during the recent coronavirus pandemic has also been demonstrated and will grow in the future. This thesis investigates novel approaches to the development and evaluation of a mixed reality-enhanced telerobotic platform for intuitive remote teleoperation applications in dangerous and difficult working conditions, such as contaminated sites and undersea or extreme welding scenarios. This research aims to remove human workers from the harmful working environments by equipping complex robotic systems with human intelligence and command/control via intuitive and natural human-robot- interaction, including the implementation of MR techniques to improve the user's situational awareness, depth perception, and spatial cognition, which are fundamental to effective and efficient teleoperation. The proposed robotic mobile manipulation platform consists of a UR5 industrial manipulator, 3D-printed parallel gripper, and customized mobile base, which is envisaged to be controlled by non-skilled operators who are physically separated from the robot working space through an MR-based vision/motion mapping approach. The platform development process involved CAD/CAE/CAM and rapid prototyping techniques, such as 3D printing and laser cutting. Robot Operating System (ROS) and Unity 3D are employed in the developing process to enable the embedded system to intuitively control the robotic system and ensure the implementation of immersive and natural human-robot interactive teleoperation. This research presents an integrated motion/vision retargeting scheme based on a mixed reality subspace approach for intuitive and immersive telemanipulation. An imitation-based velocity- centric motion mapping is implemented via the MR subspace to accurately track operator hand movements for robot motion control, and enables spatial velocity-based control of the robot tool center point (TCP). The proposed system allows precise manipulation of end-effector position and orientation to readily adjust the corresponding velocity of maneuvering. A mixed reality-based multi-view merging framework for immersive and intuitive telemanipulation of a complex mobile manipulator with integrated 3D/2D vision is presented. The proposed 3D immersive telerobotic schemes provide the users with depth perception through the merging of multiple 3D/2D views of the remote environment via MR subspace. The mobile manipulator platform can be effectively controlled by non-skilled operators who are physically separated from the robot working space through a velocity-based imitative motion mapping approach. Finally, this thesis presents an integrated mixed reality and haptic feedback scheme for intuitive and immersive teleoperation of robotic welding systems. By incorporating MR technology, the user is fully immersed in a virtual operating space augmented by real-time visual feedback from the robot working space. The proposed mixed reality virtual fixture integration approach implements hybrid haptic constraints to guide the operator’s hand movements following the conical guidance to effectively align the welding torch for welding and constrain the welding operation within a collision-free area. Overall, this thesis presents a complete tele-robotic application space technology using mixed reality and immersive elements to effectively translate the operator into the robot’s space in an intuitive and natural manner. The results are thus a step forward in cost-effective and computationally effective human-robot interaction research and technologies. The system presented is readily extensible to a range of potential applications beyond the robotic tele- welding and tele-manipulation tasks used to demonstrate, optimise, and prove the concepts

    Performance evaluation of a six-axis generalized force-reflecting teleoperator

    Get PDF
    Work in real-time distributed computation and control has culminated in a prototype force-reflecting telemanipulation system having a dissimilar master (cable-driven, force-reflecting hand controller) and a slave (PUMA 560 robot with custom controller), an extremely high sampling rate (1000 Hz), and a low loop computation delay (5 msec). In a series of experiments with this system and five trained test operators covering over 100 hours of teleoperation, performance was measured in a series of generic and application-driven tasks with and without force feedback, and with control shared between teleoperation and local sensor referenced control. Measurements defining task performance included 100-Hz recording of six-axis force/torque information from the slave manipulator wrist, task completion time, and visual observation of predefined task errors. The task consisted of high precision peg-in-hole insertion, electrical connectors, velcro attach-de-attach, and a twist-lock multi-pin connector. Each task was repeated three times under several operating conditions: normal bilateral telemanipulation, forward position control without force feedback, and shared control. In shared control, orientation was locally servo controlled to comply with applied torques, while translation was under operator control. All performance measures improved as capability was added along a spectrum of capabilities ranging from pure position control through force-reflecting teleoperation and shared control. Performance was optimal for the bare-handed operator

    A robot learning method with physiological interface for teleoperation systems

    Get PDF
    The human operator largely relies on the perception of remote environmental conditions to make timely and correct decisions in a prescribed task when the robot is teleoperated in a remote place. However, due to the unknown and dynamic working environments, the manipulator's performance and efficiency of the human-robot interaction in the tasks may degrade significantly. In this study, a novel method of human-centric interaction, through a physiological interface was presented to capture the information details of the remote operation environments. Simultaneously, in order to relieve workload of the human operator and to improve efficiency of the teleoperation system, an updated regression method was proposed to build up a nonlinear model of demonstration for the prescribed task. Considering that the demonstration data were of various lengths, dynamic time warping algorithm was employed first to synchronize the data over time before proceeding with other steps. The novelty of this method lies in the fact that both the task-specific information and the muscle parameters from the human operator have been taken into account in a single task; therefore, a more natural and safer interaction between the human and the robot could be achieved. The feasibility of the proposed method was demonstrated by experimental results

    Design of a six degree-of-freedom haptic hybrid platform manipultor

    Get PDF
    Thesis (Master)--Izmir Institute of Technology, Mechanical Engineering, Izmir, 2010Includes bibliographical references (leaves: 97-103)Text in English; Abstract: Turkish and Englishxv, 115 leavesThe word Haptic, based on an ancient Greek word called haptios, means related with touch. As an area of robotics, haptics technology provides the sense of touch for robotic applications that involve interaction with human operator and the environment. The sense of touch accompanied with the visual feedback is enough to gather most of the information about a certain environment. It increases the precision of teleoperation and sensation levels of the virtual reality (VR) applications by exerting physical properties of the environment such as forces, motions, textures. Currently, haptic devices find use in many VR and teleoperation applications. The objective of this thesis is to design a novel Six Degree-of-Freedom (DOF) haptic desktop device with a new structure that has the potential to increase the precision in the haptics technology. First, previously developed haptic devices and manipulator structures are reviewed. Following this, the conceptual designs are formed and a hybrid structured haptic device is designed manufactured and tested. Developed haptic device.s control algorithm and VR application is developed in Matlab© Simulink. Integration of the mechanism with mechanical, electromechanical and electronic components and the initial tests of the system are executed and the results are presented. According to the results, performance of the developed device is discussed and future works are addressed

    A teleoperation framework for mobile robots based on shared control

    Get PDF
    Mobile robots can complete a task in cooperation with a human partner. In this paper, a hybrid shared control method for a mobile robot with omnidirectional wheels is proposed. A human partner utilizes a six degrees of freedom haptic device and electromyography (EMG) signals sensor to control the mobile robot. A hybrid shared control approach based on EMG and artificial potential field is exploited to avoid obstacles according to the repulsive force and attractive force and to enhance the human perception of the remote environment based on force feedback of the mobile platform. This shared control method enables the human partner to tele-control the mobile robot’s motion and achieve obstacles avoidance synchronously. Compared with conventional shared control methods, this proposed one provides a force feedback based on muscle activation and drives the human partners to update their control intention with predictability. Experimental results demonstrate the enhanced performance of the mobile robots in comparison with the methods in the literature

    Haptics in Robot-Assisted Surgery: Challenges and Benefits

    Get PDF
    Robotic surgery is transforming the current surgical practice, not only by improving the conventional surgical methods but also by introducing innovative robot-enhanced approaches that broaden the capabilities of clinicians. Being mainly of man-machine collaborative type, surgical robots are seen as media that transfer pre- and intra-operative information to the operator and reproduce his/her motion, with appropriate filtering, scaling, or limitation, to physically interact with the patient. The field, however, is far from maturity and, more critically, is still a subject of controversy in medical communities. Limited or absent haptic feedback is reputed to be among reasons that impede further spread of surgical robots. In this paper objectives and challenges of deploying haptic technologies in surgical robotics is discussed and a systematic review is performed on works that have studied the effects of providing haptic information to the users in major branches of robotic surgery. It has been tried to encompass both classical works and the state of the art approaches, aiming at delivering a comprehensive and balanced survey both for researchers starting their work in this field and for the experts

    A Wave Variable Approach with Multiple Channel Architecture for Teleoperated System

    Get PDF
    © 2013 IEEE. Performance of teleoperation can be greatly influenced by time delay in the process of tele-manipulation with respect to accuracy and transparency. Wave variable is an effective algorithm to achieve a good stable capability. However, some traditional wave variable methods may decrease the performance of transparency and suffer the impacts of wave reflection. To deal with the problem of stability and transparency in teleoperation, in this paper, a novel wave variable method with four channel is presented to achieve stable tracking in position and force. In addition, the proposed method can achieve the distortion compensation and reduce the impacts of wave reflection. The simulation experimental results verified the tracking performance of the proposed method

    Model Driven Robotic Assistance for Human-Robot Collaboration

    Get PDF
    While robots routinely perform complex assembly tasks in highly structured factory environments, it is challenging to apply completely autonomous robotic systems in less structured manipulation tasks, such as surgery and machine assembly/repair, due to the limitations of machine intelligence, sensor data interpretation and environment modeling. A practical, yet effective approach to accomplish these tasks is through human-robot collaboration, in which the human operator and the robot form a partnership and complement each other in performing a complex task. We recognize that humans excel at determining task goals and recognizing constraints, if given sufficient feedback about the interaction between the tool (e.g., end-effector of the robot) and the environment. Robots are precise, unaffected by fatigue and able to work in environments not suitable for humans. We hypothesize that by providing the operator with adequate information about the task, through visual and force (haptic) feedback, the operator can: (1) define the task model, in terms of task goals and virtual fixture constraints through an interactive, or immersive augmented reality interface, and (2) have the robot actively assist the operator to enhance the execution time, quality and precision of the tasks. We validate our approaches through the implementations of both cooperative (i.e., hands-on) control and telerobotic systems, for image-guided robotic neurosurgery and telerobotic manipulation tasks for satellite servicing under significant time delay

    Optical coherence tomography-based consensus definition for lamellar macular hole.

    Get PDF
    BackgroundA consensus on an optical coherence tomography definition of lamellar macular hole (LMH) and similar conditions is needed.MethodsThe panel reviewed relevant peer-reviewed literature to reach an accord on LMH definition and to differentiate LMH from other similar conditions.ResultsThe panel reached a consensus on the definition of three clinical entities: LMH, epiretinal membrane (ERM) foveoschisis and macular pseudohole (MPH). LMH definition is based on three mandatory criteria and three optional anatomical features. The three mandatory criteria are the presence of irregular foveal contour, the presence of a foveal cavity with undermined edges and the apparent loss of foveal tissue. Optional anatomical features include the presence of epiretinal proliferation, the presence of a central foveal bump and the disruption of the ellipsoid zone. ERM foveoschisis definition is based on two mandatory criteria: the presence of ERM and the presence of schisis at the level of Henle's fibre layer. Three optional anatomical features can also be present: the presence of microcystoid spaces in the inner nuclear layer (INL), an increase of retinal thickness and the presence of retinal wrinkling. MPH definition is based on three mandatory criteria and two optional anatomical features. Mandatory criteria include the presence of a foveal sparing ERM, the presence of a steepened foveal profile and an increased central retinal thickness. Optional anatomical features are the presence of microcystoid spaces in the INL and a normal retinal thickness.ConclusionsThe use of the proposed definitions may provide uniform language for clinicians and future research
    corecore